
5.3.6
Resetting the boot retry counter
The boot retry counter is decremented from its preset value every time the
POST watchdog initiates a system reboot. When the value has reached ’0’, the
system will shut down and power off.
Viewing the boot retry counter
The current boot retry counter status is available in the BIOS:
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Retry Counter
the current number of remaining boot attempts
is displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
▶
Exit the BIOS.
Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
Please note, if the customer does not know about the original boot retry
values:
If the system boots up and no further errors occur within 6 hours after
that successful boot attempt, the boot retry counter will automatically be
reset to its default value. Please take into account, that the specified
number of boot attempts can only be determined after this period of
time.
If the customer knows about the original boot retry values, proceed as follows
to reset or configure the boot retry counter:
Resetting the boot retry counter in the BIOS
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Retry Counter
press the [+] or [-] keys to specify the maximum
number of boot attempts (0 to 7).
Basic software procedures
76
Upgrade and Maintenance Manual
RX2520 M5
Содержание PRIMERGY RX2520 M5
Страница 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 296: ...Figure 177 Installing the ODD A Insert the ODD Accessible drives 296 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 301: ...Figure 181 Removing the ODD A Unlock the ODD latch 1 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 301 ...
Страница 343: ... Resuming BitLocker functionality on page 88 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 343 ...
Страница 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 427: ...Figure 280 Removing the system board System board and components RX2520 M5 Upgrade and Maintenance Manual 427 ...
Страница 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 464: ...FUJITSU Server PRIMERGY RX2520 M5 Reference Manual Reference Manual English Cable Plan for March 2022 ...
Страница 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...