7.5.4
Replacing a 2.5-inch HDD/SSD module
Customer Replaceable
Unit (CRU)
Hardware: 5 minutes
Tools:
Phillips PH1 / (+) No. 1 screw driver (for installation frame)
PCIe SSDs SFF are installed in the same frames as the 2.5-inch
HDD/SSD modules. Therefore, this section is also valid and applicable if
PCIe SSDs SFF are used.
CAUTION
▶
Only remove an HDD/SSD module during operation if the drive is
not currently being accessed. Observe the indicators on the
corresponding HDD/SSD module, see
.
▶
An HDD/SSD module can be replaced while the system is in
operation.
RAID configuration with a RAID controller:
●
Modular Host Bus Adapter with "Integrated RAID" (IR). RAID
levels 0 and 1 are supported for internal HDD configurations.
●
Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1, 10, 5 and 50 are
supported for internal HDD configurations.
●
Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
▶
An HDD/SSD module can be replaced while the system is in
operation.
RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
▶
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
Hard disk drive (HDD) / solid state disk (SSD)
178
Upgrade and Maintenance Manual
RX2520 M5
Содержание PRIMERGY RX2520 M5
Страница 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 296: ...Figure 177 Installing the ODD A Insert the ODD Accessible drives 296 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 301: ...Figure 181 Removing the ODD A Unlock the ODD latch 1 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 301 ...
Страница 343: ... Resuming BitLocker functionality on page 88 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 343 ...
Страница 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 427: ...Figure 280 Removing the system board System board and components RX2520 M5 Upgrade and Maintenance Manual 427 ...
Страница 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 464: ...FUJITSU Server PRIMERGY RX2520 M5 Reference Manual Reference Manual English Cable Plan for March 2022 ...
Страница 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...