94
Operating Manual
RX200
S5
Replacement of non-hot-plug components
CSS components
8.2
Replacement of non-hot-plug components
When a defective non-hot-plug component is detected (for more information,
see chapter
"Starting up and operation" on page 55
and the "Customer Self
Service (CSS)" manual on the ServerView Suite DVD 2), proceed as follows:
Ê
Exit all applications and shut down the server properly (see section
"Switching the server on and off" on page 65
Ê
Pull all power plugs out of the insulated sockets of the rack's internal power
supply.
Ê
Remove the server from the rack (see section
"Installing/removing the server
) and put the server on a table, for example.
8.2.1
Opening the server
You must remove the fan cover before removing the housing cover:
Figure 27: Opening the fan cover
Ê
Push the two green buttons (1) in the direction of the arrow and lift the fan
cover up and off.
1
1
2