RX200 S5
Operating Manual
47
Hardware installation
Installing/removing the server in/from the rack
Inserting the server
Figure 7: Inserting the server
V
CAUTION!
Ensure that the safety lock has been inserted
before
the server is
inserted (see
).
V
CAUTION!
At least two people are needed to position the server in the rack.
Ê
Extend the interior telescopic rails completely to the front (1).
I
They must click into place so that they can no longer be moved.
Ê
Insert the prepared server into the protruding interior telescope rails (2) until
the rails engage.
Ê
Release the locking mechanism of both rails - see (3a) for fully extending
rails and (3b) for partially extending rails.
Ê
Push the server as far as it will go into the rack (4).
Ê
Fasten the server to the rack (5) using the two knurled screws (front panel).
Ê
Route the cables as described in the technical manual for the rack in
question with the server pushed in.
1
2
4
4
5
5
3a
3b