RX1330 M3
Upgrade and Maintenance Manual
147
Hard disk drive (HDD) / solid state drive (SSD)
7.2.6
Removing 2.5-inch HDD/SSD modules
7.2.6.1
Preliminary steps
Ê
If the HDD/SSD module to be removed is combined into a RAID array,
please proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array! Be sure to back up your data before deleting a RAID
array.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
.
Содержание PRIMERGY RX1330 M3
Страница 20: ...Upgrade and Maintenance Manual RX1330 M3 Contents ...
Страница 48: ...48 Upgrade and Maintenance Manual RX1330 M3 Important information ...
Страница 70: ...70 Upgrade and Maintenance Manual RX1330 M3 Basic hardware procedures ...
Страница 132: ...132 Upgrade and Maintenance Manual RX1330 M3 Power supply unit PSU ...
Страница 178: ...178 Upgrade and Maintenance Manual RX1330 M3 Hard disk drive HDD solid state drive SSD ...
Страница 184: ...184 Upgrade and Maintenance Manual RX1330 M3 Fans ...
Страница 222: ...222 Upgrade and Maintenance Manual RX1330 M3 Expansion cards and backup units ...
Страница 244: ...244 Upgrade and Maintenance Manual RX1330 M3 Processor CPU ...
Страница 310: ...310 Upgrade and Maintenance Manual RX1330 M3 System board and components ...