U41271-J-Z156-2-76
21
Installation
Installing the Rack Model in the Rack
3.4
Installing the Rack Model in the Rack
V
CAUTION!
●
Please observe the safety precautions and references to mounting
into the rack in chapter “Important Notes” on page 7.
●
At least two people are needed to position the server in the rack.
●
The rack can tip over if more than one unit is removed.
●
The server may not occupy the top height unit of the rack (42 HU
Classic Rack, 38 HU/42HU PRIMECENTER Rack and/or DataCenter
Rack), as otherwise no board can be replaced even with the slide-in
module pulled out completely.
3.4.1
Requirements of the Rack
The rack systems of the Fujitsu Siemens Computers GmbH (19-Inch (Classic)
Rack; DataCenter Rack and PRIMECENTER Rack) support fully the installation
of the PRIMERGY server systems. The installation into the at present usual
rack systems of different foreign manufacturers (3rd-Party Rack) is supported
to large part.
To accommodate the ventilation concept and ensure proper ventilation of the
components in the rack, any unused areas must be closed using dummy covers.
The power is supplied via the socket strips available in the rack.
The main features of the rack systems of the Fujitsu Siemens Computers GmbH
are:
PRIMECENTER Rack
–
In connection with so-called assembly brackets frontally bolted telescopic
rails or sliding rails.
These assembly brackets and/or the sliding rails are provided with a linear
alignment possibility to ensure also an adjustment to different rack depths.
–
Extended cable management within the lateral rack area.