Introduction
Technical data
Weight
approx. 60 kg (depending on the configuration)
Ventilation intervals for the floorstand model
To ensure sufficient ventilation of the system, a minimum clearance of 200 mm
must be provided at the front and the rear of the server.
Maintenance area for the floorstand model
1.2 m on the left side. The maintenance area may also be used, but must be
quickly accessible.
Environmental conditions
Condensation during operation must be avoided.
Noise level
Environment class 3K2
Environment class 2K2
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature:
–
Operating (3K2)
–
Transport (2K2)
10 °C .... 35 °C
-25 °C .... 60 °C
Foreign particles:
–
Humidity
–
Floating dust
20 % .... 80 %
0.15 mg/m³ or less
Sound power level L
WAd
(ISO 9296):
≤
6.0 B
Sound pressure level at bystander
position L
pAm
(ISO 9296)
≤
45 dB(A)