28
Upgrade and Maintenance Manual
GX2460 M1
Important information
●
If the server is brought in from a cold environment, condensation may form
both inside and on the outside of the server.
Wait until the server has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the server if this
requirement is not observed.
●
Only transport the server in its original packaging or in packaging that
protects it from impacts and jolts.
In Japan and APAC, transporting the server in its original packaging does
not apply.
Installation and operation
●
This server should not be operated in ambient temperatures above 35 °C.
For servers with Advanced Thermal Design the ambient temperature can
increase to 40 °C or 45 °C.
●
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
The server automatically adjusts itself to a mains voltage, see the type label
of your server. Ensure that the local mains voltage lies within these limits.
●
This server must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution server with
tested and approved power cords.
●
Ensure that the server is connected to a properly grounded power outlet
close to the server.
●
Ensure that the power sockets on the server and the properly grounded
power outlets are easily accessible.
●
The On/Off button or the main power switch (if present) does not isolate the
server from the mains power supply. In case of repair or servicing disconnect
the server completely from the mains power supply, unplug all power plugs
from the properly grounded power outlets.
●
Always connect the server and the attached peripheral devices to the same
power circuit. Otherwise you run the risk of losing data if, for example, the
server is still running but a peripheral device (e.g. memory subsystem) fails
during a power outage.
●
The adequately shielded data cables must be used.
Содержание PRIMERGY GX2460 M1
Страница 16: ...16 Upgrade and Maintenance Manual GX2460 M1 Contents ...
Страница 26: ...26 Upgrade and Maintenance Manual GX2460 M1 Before you start ...
Страница 56: ...56 Upgrade and Maintenance Manual GX2460 M1 Basic hardware procedures ...
Страница 78: ...78 Upgrade and Maintenance Manual GX2460 M1 Power supply unit PSU ...
Страница 96: ...96 Upgrade and Maintenance Manual GX2460 M1 Hard disk drive HDD and solid state drive SSD ...
Страница 108: ...108 Upgrade and Maintenance Manual GX2460 M1 Fans ...
Страница 143: ...GX2460 M1 Upgrade and Maintenance Manual 143 Expansion cards and riser modules Ê Switching on the server on page 54 ...
Страница 153: ...GX2460 M1 Upgrade and Maintenance Manual 153 Expansion cards and riser modules Ê Switching on the server on page 54 ...
Страница 158: ...158 Upgrade and Maintenance Manual GX2460 M1 Expansion cards and riser modules ...
Страница 225: ...GX2460 M1 Upgrade and Maintenance Manual 225 Appendix A Figure 183 Indicators on the system board ...
Страница 242: ...242 Upgrade and Maintenance Manual GX2460 M1 Appendix A ...
Страница 244: ...244 Upgrade and Maintenance Manual GX2460 M1 Appendix B ...
Страница 250: ...RAID Card RAID Card HDD Back Plane 411T61300070 SAS MLC1 SAS MLC2 SATA 0 3 SATA 4 7 C17 C17 ...