Important information
Before starting up
V
CAUTION!
●
During installation and before operating the device, observe the
instructions on environmental conditions for your device (see
"Server
node specification" on page 15
).
●
If the server node has been moved from a cold environment,
condensation may form both inside and on the outside of the
machine.
Wait until the server node has acclimatized to room temperature and
is absolutely dry before starting it up. Material damage may be
caused to the server node if this requirement is not met.
●
Only transport the server node in the original packaging or in
packaging that protects it from impacts and jolts.
Installation and operation
V
CAUTION!
●
This unit should not be operated in ambient temperatures above
35 °C. For servers with Cool-safe® Advanced Thermal Design the
ambient temperature can increase to 40 °C.
●
If the unit is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
The unit automatically adjusts itself to a mains voltage in a range of
100 - 240 V. Ensure that the local mains voltage lies within these
limits.
●
This device must only be connected to properly grounded power
outlets or insulated sockets of the rack's internal power supply with
tested and approved power cords.
●
Ensure that the device is connected to a properly grounded power
outlet close to the device.