4 Installing Drivers and Utilities
59
E
7
For the BootBIOS version, check the "Revision" value in "Boot Bios
Firmware".
• When the version is "1.70a3", proceed to Step 11.
• When the version is other than "1.70a3", proceed to Step 8.
8
Click the [Download] button.
Although the warning window appears, click [OK].
9
Insert the driver disk (CD-ROM) into the CD-ROM drive, select the
BootBIOS file in the CD-ROM drive, and click [Open].
[CD-ROM drive]:\FirmBIOS\ZB170A3.PRG
BootBIOS update starts.
10
Check that the "Revision" value in "Boot Bios Firmware" became
"1.70a3".
For PG-FCD201, perform procedures as above to all adapter.
11
After checking versions of all adapters, restart the server blade to
enable the settings, and proceed to "5 4Gbit/s FC I/O Module
Details Setting" (
pg.62).
When replacing this product, perform "4.3 Checking and Updating Firmware /
BootBIOS" (
pg.58) again as necessary.