Data assurance in the event of power failure
Except for the data block being written to, the data on the disk media is assured in the event of
any power supply abnormalities. This does not include power supply abnormalities during
disk media initialization (formatting) or processing of defects (alternative block assignment).
1.8
Error Rate
Known defects, for which alternative blocks can be assigned, are not included in the error rate
count below. It is assumed that the data blocks to be accessed are evenly distributed on the
disk media.
(1)
Unrecoverable read error
Read errors that cannot be recovered by maximum 126 times read retries without user's retry
and ECC corrections shall occur no more than 10 times when reading data of 10
15
bits. Read
retries are executed according to the disk drive's error recovery procedure, and include read
retries accompanying head offset operations.
(2)
Positioning error
Positioning (seek) errors that can be recovered by one retry shall occur no more than 10 times
in 10
7
seek operations.
1.9
Media Defects
Defective sectors are replaced with alternates when the disk is formatted prior to shipment
from the factory (low level format). Thus, the host sees a defect-free device.
Alternate sectors are automatically accessed by the disk drive. The user need not be concerned
with access to alternate sectors.
Chapter 6 describes the low level format at shipping.
Содержание MPC3032AT
Страница 1: ...C141 E055 03EN MPC3032AT MPC3043AT MPC3064AT MPC3084AT MPC3096AT MPC3102AT DISK DRIVES PRODUCT MANUAL ...
Страница 3: ...This page is intentionally left blank ...
Страница 7: ...This page is intentionally left blank ...
Страница 15: ...This page is intentionally left blank ...
Страница 31: ...This page is intentionally left blank ...
Страница 33: ...C141 E055 02EN 3 2 Figure 3 1 Dimensions ...
Страница 48: ...C141 E055 01EN 4 5 Figure 4 2 MPC30xxAT Block diagram ...
Страница 54: ...C141 E055 01EN 4 11 Figure 4 4 Read write circuit block diagram ...
Страница 179: ......