MB91F465XA EMULATION
Chapter 2 Hardware Setup
© Fujitsu Microelectronics Europe GmbH
- 11 -
MCU-AN-300015-E-V11
6. Power all parts, afterwards the connection to the Softune Workbench Debug
Environment is possible.
Following order should be used to power up the emulation system
1. Emulator MB2198-01
2. Adapter board EMA-MB91V460A-00x
3. Target system
To power down the system use the inverse order:
1. Target system
2. Adapter board EMA-MB91V460A-00x
3. Emulator MB2198-01
Note:
When using the Fujitsu SK-91465X-100PMC evaluation board, the
polarity of power supply is contrary to that of the EMA-
MB91V460A-00x!