C141-C011
2-23
Table 2.6
Transfer mode setup request from IDD to INIT
(SDTR: SYNCHRONOUS DATA TRANSFER REQUEST message)
Message from IDD
Response from INIT
Transfer mode to be defined
SDTR
MESSAGE REJECT
Asynchronous mode
REQ/ACK Offset = X'7F'
REQ/ACK
X'00'
Asynchronous mode
Offset
X'01'
:
X'7F'
Synchronous mode
REQ/ACK offset < Specified value by INIT
X'80'
:
REQ/ACK offset= X'7F'
Transfer Period = X'0A'
(25 ns)
(LVD mode)
Transfer
Period
X'00'
:
X'09'
Synchronous mode (40.0 MB/s max.) 8-bit mode
(80.0 MB/s max.) 16-bit mode
REQ Period > 25 ns
ACK Period > 25 ns
X'0A' (25 ns)
Synchronous mode (40.0 MB/s max.) 8-bit mode
(80.0 MB/s max.) 16-bit mode
REQ Period > 25 ns
ACK Period > Specified value by Init
X'0B' (50.0 ns) Synchronous mode (20.0 MB/s max.) 8-bit mode
(40.0 MB/s max.) 16-bit mode
REQ Period > 50.0 ns
ACK Period > Specified value by Init
Transfer
Period =
X'0C' (50 ns)
(SE mode)
X'0C' (50 ns)
Synchronous mode (20.0 MB/s max.) 8-bit mode
(40.0 MB/s max.) 16-bit mode
REQ Period > 50 ns
ACK Period > Specified value by INIT
X'0D'
:
X'12' (72 ns)
Synchronous mode (13.3 MB/s max.) 8-bit mode
(26.6 MB/s max.) 16-bit mode
REQ Period > 75 ns
ACK Period > Specified value by INIT
X'13' (76 ns)
:
X'19'(100 ns)
Synchronous mode (10.0 MB/s max.) 8-bit mode
(20.0 MB/s max.) 16-bit mode
REQ Period > 100 ns
ACK Period > Specified value by INIT
X'1A' (104 ns)
:
X'1F' (124 ns)
Synchronous mode (8.00 MB/s max.) 8-bit mode
(16.0 MB/s max.) 16-bit mode
REQ Period > 125 ns
ACK Period > Specified value by INIT
X'20' (128 ns)
:
X'25' (148 ns)
Synchronous mode (6.67 MB/s max.) 8-bit mode
(13.33 MB/s max.) 16-bit mode
REQ Period > 150 ns
ACK Period > Specified value by INIT
X'26' (152 ns)
:
X'2B' (172 ns)
Synchronous mode (5.71 MB/s max.) 8-bit mode
(11.42 MB/s max.) 16-bit mode
REQ Period > 175 ns
ACK Period > Specified value by INIT
X'2C' (176 ns)
:
X'32' (200 ns)
Synchronous mode (5.00 MB/s max.) 8-bit mode
(10.00 MB/s max.) 16-bit mode
REQ Period > 200 ns
ACK Period > Specified value by INIT
X'33' (204 ns)
:
X'FF' (1020 ns)
Asynchronous mode (*1)
*1
If the INIT responds to these values during transfer period with non-zero and REQ/ACK offset, the
IDD sends the MESSAGE REJECT message following the INIT's SYNCHRONOUS TRANSFER
REQUEST message and forcibly switches the synchronous transfer mode to the asynchronous
transfer mode.
S
D
T
R
Содержание MAW3073 SERIES
Страница 6: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 27: ...C141 C011 1 9 M M 0 61 5 16 0 001 0 396 Figure 1 5 SCSI interface connector cable side 16 bit SCSI ...
Страница 61: ...C141 C011 1 43 2 SE Fast 20 Figure 1 21 is the Fast 20 measurement point Figure 1 21 Fast 20 Measurement Point ...
Страница 69: ...C141 C011 1 51 Figure 1 26 ARBITRATION phase ...
Страница 116: ...1 98 C141 C011 Figure 1 43 Bus phase sequence 1 of 2 ...
Страница 117: ...C141 C011 1 99 Figure 1 43 Bus phase sequence 2 of 2 ...
Страница 118: ...1 100 C141 C011 Figure 1 44 Example of bus phase transition at execution of a single command 1 of 5 ...
Страница 119: ...C141 C011 1 101 Figure 1 44 Example of bus phase transition at execution of a single command 2 of 5 ...
Страница 120: ...1 102 C141 C011 RESELECTION Figure 1 44 Example of bus phase transition at execution of a single command 3 of 5 ...
Страница 121: ...C141 C011 1 103 Figure 1 44 Example of bus phase transition at execution of a single command 4 of 5 ...
Страница 122: ...1 104 C141 C011 Figure 1 44 Example of bus phase transition at execution of a single command 5 of 5 TASK COMPLETE ...
Страница 127: ...C141 C011 1 109 Figure 1 47 SPI information unit sequence during initial connection ...
Страница 128: ...1 110 C141 C011 Figure 1 48 SPI information unit sequence during data type transfers ...
Страница 129: ...C141 C011 1 111 Figure 1 49 SPI information unit sequence during data stream type transfers ...
Страница 130: ...1 112 C141 C011 Figure 1 50 SPI information unit sequence during status transfers ...
Страница 154: ...1 136 C141 C011 Figure 1 56 Connection to the LVD receivers ...
Страница 160: ...2 2 C141 C011 Figure 2 1 Message format ...
Страница 165: ...C141 C011 2 7 Figure 2 2 SCSI pointer configuration ...
Страница 200: ...This page is intentionally left blank ...
Страница 204: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 208: ...This page is intentionally left blank ...
Страница 209: ......
Страница 210: ......