4.1 Control/Sense Commands
C141-C009
4-89
a. Page
code
This field identifies which log page is being transferred.
The log pages that can be transferred by this command are shown in Table 4.41.
Table 4.41 Page code
Page Code
Description
Changeable Parameter
01
Buffer Overrun/Underrun Page
Disable
02
Write Error Counter Page
Enable
03
Read Error Counter Page
Enable
05
Verify Error Counter Page
Enable
06
Non-medium Error Page
Enable
0D Temperature
Page
Disable
0E
Start-stop Cycle Counter Page
Enable only 0002
0F
Application Client Log Page
Enable
10
Self-Test Result Log Page
Disable
b. Page
length
This field specifies the length in bytes of the following log parameters. If the
application client sends a page length that results in the truncation of any
parameter, the device server terminates the command with CHECK CONDITION
status (ILLEGAL REQUEST [=5] / Invalid field in parameter list [=26-00]).
The log pages contain one or more special data structures called log parameters as
shown below. Each log parameter begins with a 4-byte parameter header followed
by one or more bytes of "Parameter Value" data.
Table 4.42 Page descriptor
Bit
Byte
7 6 5 4 3 2 1 0
0
Parameter Code (MSB)
1
Parameter Code (LSB)
2 DU DS
TSD
ETC TMC LBIN
LP
3 Parameter
Length
4
n
Parameter Value
~
~
~
Содержание MAU3036RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 370: ...This page is intentionally left blank ...
Страница 372: ...This page is intentionally left blank ...
Страница 384: ...This page is intentionally left blank ...
Страница 386: ...This page is intentionally left blank ...
Страница 388: ...This page is intentionally left blank ...
Страница 390: ...This page is intentionally left blank ...
Страница 391: ......
Страница 392: ......