4.1 Control/Sense Commands
C141-C009
4-35
(2) Disconnect/reconnect parameters (page code = 2)
The format of the page descriptor in this MODE SELECT parameter is shown in
Table 4.17.
Table 4.17 MODE SELECT parameters: disconnect/reconnect parameters
Bit
Byte
7 6 5 4 3 2 1 0
0 0 0 0 0 0 0 1 0
1
X ' 0E ' (Page Length)
2
X ' 00 '
3
X ' 00 '
4-5
Bus Inactivity Ratio
Default
X ' 0000 '
Variable
X ' 0000 '
6-7
X ' 0000 '
8-9
Connect Time Limit
Default
X ' 0000 '
Variable
X ' 0000 '
10-11
Maximum Burst Size
Default
X ' 0000 '
Variable
X ' 0000 '
12
X ' 00 '
13
X ' 00 '
14-15
(Burst Size During the Initialize Connection)
Default
X ' 0000 '
Variable
X ' 0000 '
a. Bus inactivity ratio
This parameter specifies the maximum period of time from the time of OPEN
processing for the address frame during which the TARG executes no
operations as a multiple of 100
µ
s.
The IDD ignores the value specified by this parameter and operates according
to the default value of '000A.'
Содержание MAU3036RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 370: ...This page is intentionally left blank ...
Страница 372: ...This page is intentionally left blank ...
Страница 384: ...This page is intentionally left blank ...
Страница 386: ...This page is intentionally left blank ...
Страница 388: ...This page is intentionally left blank ...
Страница 390: ...This page is intentionally left blank ...
Страница 391: ......
Страница 392: ......