SAFETY PRECAUTIONS 

 

List of important warnings 

The table below contains a list of important warning indications. 

 

Work type 

Warning 

Normal use

 

Possibility of electric shock and fire 

If an excessive heat, smoke, an abnormal odor or an unusual noise is coming from this 

equipment, immediately set its power switch to OFF and remove the power cord plug 

from the power receptacle.    Then, contact a Fujitsu Service Center. 

This indicates a hazardous situation that could lead to fire and electric shock. 

 

Possibility of electric shock and fire 

If foreign matter (e.g., water, bits of metal, fluid) gets inside this equipment, immediately 

set its power switch to OFF and remove the power cord plug from the power receptacle.  

Then, contact a Fujitsu Service Center. 

This indicates a hazardous situation that could lead to fire and electric shock. 

 

Possibility of electric shock and fire 

If  this equipment  has been dropped or otherwise damaged, immediately set its power 

switch to OFF and remove the power cord plug from the power receptacle.  Then, 

contact a  Fujitsu Service Center. 

This indicates a hazardous situation that could lead to electric shock. 

 

Possibility of electric shock and fire 

To keep foreign matter out, ensure that drink containers and metal objects are not placed 

on or near this equipment. 

The presence of foreign matter such as water inside this equipment creates a hazardous     

situation that could lead to electric shock. 

 

Possibility of electric shock and fire 

Ensure that no liquid is splashed on this equipment, making it wet. 

The presence of foreign matter such as water inside this equipment creates a hazardous     

situation that could lead to fire and electric shock. 

 

Possibility of electric shock and fire 

Ensure that the power cord does not become damaged, and avoid tampering with it. 

If the power cord has a heavy object is placed on it, pulled at, bent, or becomes entangled, it 

could be damaged as a result.    Also, the power cord could be damaged if subjected to heat, 

creating a hazardous situation that could lead to fire and electric shock. 

 

 

Indicates a situation that could lead to serious injury or loss of life if procedures 

are not followed correctly. 

 

Содержание IP-920 E/DC

Страница 1: ...IP 920E DC Hardware User s Guide ...

Страница 2: ... This page is intentionally left blank ...

Страница 3: ...Canada users only This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations The following notice is for EU European Union users only This is Class A product of Electromagnetic Interference EMI standard In a domestic environment this product may cause radio interference in which case the user may be required to make adequate measures This manua...

Страница 4: ...U assumes no liability to any party for any damage caused by any error or omission contained in this manual its updates or supplements whether such errors or omissions result from negligence accident or any other cause In addition FUJITSU assumes no liability with respect to the application or use of any product or system in accordance with descriptions or instructions contained herein including a...

Страница 5: ...ar device and distributes it across the network in real time This manual is intended for system designers and system managers who use IP 920E DC Readers are assumed to have a basic knowledge of networks and video distribution 1 IP 920E DC supports only SD video By adding optional software IP 920E DC will be upgraded to support HD video Product operating environment Designed for use in real time au...

Страница 6: ...ents Chapter 3 Operating Instructions This chapter explains how to power on off set up and operate this equipment Chapter 4 Connection Cable Specifications This chapter contains a classification of how work is implemented cable connection system diagrams and cable connector details Chapter 5 Troubleshooting This chapter describes actions to be taken if this equipment does not operate normally or i...

Страница 7: ... a line Left and right indents are set for warning messages to differentiate them from ordinary text Furthermore the lines immediately before and after warning indications are left blank Example Possibility of electric shock fire and damage to this equipment Always observe the precautions given below This indicates a hazardous situation that could lead to electric shock fire or damage to this equi...

Страница 8: ...move the power cord plug from the power receptacle Then contact a Fujitsu Service Center This indicates a hazardous situation that could lead to electric shock Possibility of electric shock and fire To keep foreign matter out ensure that drink containers and metal objects are not placed on or near this equipment The presence of foreign matter such as water inside this equipment creates a hazardous...

Страница 9: ... field Location where the temperature is too hot or cold In an environment with sharp temperature fluctuations Area with poor ventilation Near a fire Possibility of electric shock fire and damage to this equipment Always observe the precautions given below This indicates a hazardous situation that could lead to fire and damage to this equipment Choose a power supply that meets the nominal voltage ...

Страница 10: ...isconnect all connected cables Take care to avoid getting your feet entangled in the cables To prevent serious personal injury when moving this equipment take special care to pay attention to your surroundings Clean Possibility of fire serious injury and damage to this equipment When cleaning this equipment observe the following precautions to protect against fire serious injury and damage to this...

Страница 11: ...ul interference and 2 this device must accept any interference received including interference that may cause undesired operation MADE IN JAPAN 3 2A 1 6A 12V 24V 2 3kg FUJITSU LIMITED T 認証番号 01A 11 03 00001 D08 0454001 00001 I T E ACCESSORY LISTED R C US 1K91 E136004 MODEL PART NO IP 920E DC TA23742 B72X This device complies with Part 15 of the FCC Rules operation is subject to the following two c...

Страница 12: ...le devices are connected the result may be personal injury and property damage CF card consideration Please note that you need to remove the CF card or take the backup of its recorded data in case of requesting the repair of the main unit that the CF card is installed since Fujitsu does not guarantee the recorded content during the repair work Please also note that the recorded content might be de...

Страница 13: ... Connection to power source 33 2 3 AudioandVideoDeviceConnections 35 2 4 Connection to Network 36 2 5 Connection to RS 232C Device 37 2 6 CF Card Insertion and Removal 38 Chapter 3 Operation Instructions 41 3 1 Turn ON OFF IP 920E DC 43 3 1 1 Turn on IP 920E DC 43 3 1 2 Turn off IP 920E DC 43 3 2 Device Settings and Operation 44 3 2 1 Reboot 45 3 3 Special Use of MNT Button 46 Chapter 4 Cable Spec...

Страница 14: ...ions 73 A 2 3 Function specifications 74 A 3 Preparations for Installation Work 79 A 3 1 Scope of installation work 79 A 3 2 Unpacking and device check 79 A 3 3 Installation conditions 79 A 3 4 Connecting external cables 79 A 4 Preparations for On site Turn up 80 Glossary and Index 83 Glossary 85 Index 88 CE Conformity Information 90 ...

Страница 15: ...eparations This chapter describes the checks that are required before the start of IP 920E DC operation 1 1 Main Features 3 1 2 Components 4 1 3 Basic Application Examples 5 1 4 Part Names 6 CHAPTER 1 PREPARATIONS ...

Страница 16: ... This page is intentionally left blank ...

Страница 17: ...dded 2ch BNC 1 stereo pairs HDMI 1 2a 2 2ch HDMI Analog balanced 2ch D sub9 pin female connector 1 stereo pair Network LAN 1ch RJ45 10BASE T 100BASE TX Data input output RS 232C 1ch D sub9 pin male connector CF CARD slot CF CARD 1 Data storage application Installation conditions Indoor On a desk mounted in a rack Dimensions W 210 H 42 D 300 mm Note Excluding protrusions i e not including feet Cool...

Страница 18: ...ists of the following components Attachments for all series consist of same contents IP 920E DC 1 pc cables separate order Safety manual 1pc User s Guide 1pc Feet 4 pcs DC Power cable 1 pc Audio adapter cable type 1 1 pc CF CARD ACT RDY PWR ALM IN DWN OPT 100M LINK E 1 2 A IN L A IN L A IN R ...

Страница 19: ...T RDY PWR ALM IN DWN OPT 100M LINK E RDY PWR ALM DEC MNT FG ACT 100M LINK 10 100BASE RS 232C ANALOG VIDEO OUT 100 240V SDI D ANALOG AUDIO OUT IP Network FTTB FTTH Dart Fiber AP AP HD VTR HD Camera AP Encoder Site Live Coverage IP 920E DC Monitoring Control HD Archive Server Strage NR AP Dual Encoding SD File Transfer by Flow Control HD VTR Video Editing Equipment On demand file transfer From affil...

Страница 20: ...atus LED RDY Turn on when IP 920E power is on For more information see Table 5 3 Details of LED Indications in Section 5 2 5 Alarm LED ALM Turns on when IP 920E operation is abnormal For more information see Table 5 3 Details of LED Indications in Section 5 2 6 AV input status LED INDWN Audio Video input setting status indicator and LED that indicates the input off status during input setting For ...

Страница 21: ...G Use for an FG connection to this equipment See Section 2 2 1 Connection to ground for an explanation on using this terminal 14 Maintenance mode switch MNT IP 920E start mode selector switch when the IP 920E is powered on with this switch held down it starts in initial start mode See section 3 3 Special Use of MNT Button for an explanation on using this switch 15 HDMI input HDMI Digital HDMI vide...

Страница 22: ... This page is intentionally left blank ...

Страница 23: ... and explains how to connect it to peripheral devices 2 1 Installation Conditions 11 2 2 Power Supply System Connections 32 2 3 AudioandVideoDeviceConnections 35 2 4 Connection to Network 36 2 5 Connection to RS 232C Device 37 2 6 CF Card Insertion and Removal 38 CHAPTER 2 INSTALLATION AND CONNECTION ...

Страница 24: ...erious injury The power cord and other cables connected to IP 920E DC may become entangled with someone walking close to them possibly leading to serious injury and property damage Clamp the cables to the rack or floor ...

Страница 25: ...kably amount of dust is the cause of equipment errors and failures if it is attached to the equipment Use this Equipment in the environment which gaseous contamination is under IEC 60721 3 3 Class 3C1 Refer to Appendix 2 2 Environment Specifications Gaseous contamination 2 1 2 Installation environment 1 19 rack mounting Mount this equipment to 19 rack of EIA standard using the 19 rack mounting kit...

Страница 26: ...Connection IP 920E DC 12 Two IP 920 per 1U Type C2 1 Check contents of the rack mounting kit 2 Check all cables disconnected 3 Connect the first device with the rack mounting kit A and B on IP 920 using six same screws M4 C B A D ...

Страница 27: ...Chapter 2 Installation and Connection IP 920E DC 13 4 Connect the second device with the rack mounting kit A and B on IP 920 using six same screws M4 ...

Страница 28: ...Chapter 2 Installation and Connection IP 920E DC 14 5 Install the mounting kit C on IP 920 using two pan head screws M5 ...

Страница 29: ...he desired height on the 19 rack and firmly secure the unit in position with the screws supplied with this product Use four pan head screws M5 to fix the product in position To secure the unit to a server rack use the cage nuts D and bind head screws M6 supplied with this product ...

Страница 30: ...the device 1 When removing two devices at the same time Remove them by reversing the installation procedure for two devices 2 When removing only one device Remove the four screws shown in the figure below Remove the mounting brackets C and then remove the device ...

Страница 31: ...tallation and Connection IP 920E DC 17 1 unit per 1U Type A1 1 Check components of the rack mounting kit 2 Check all cables are disconnected 3 Install the rack mounting kit A on IP 920 using three same screws M4 B A ...

Страница 32: ...ction IP 920E DC 18 4 Install the rack mounting kit B on IP 920 series using three same screws M4 5 Install IP 920 on 19 rack using four pan head screws M5 Removing the device Remove the device by reversing the installation procedure ...

Страница 33: ...onnection IP 920E DC 19 2 units per 1U Type A2 1 Check components of the rack mounting kit 2 Check all cables are disconnected 3 Connect the first device with the rack mounting kit A and B on IP 920 using six same screws M4 C B A ...

Страница 34: ...apter 2 Installation and Connection IP 920E DC 20 4 Install IP 920 on 19 rack using two pan head screws M5 5 Connect the second device with the rack mounting kit A and B on IP 920 using six same screws M4 ...

Страница 35: ...Chapter 2 Installation and Connection IP 920E DC 21 6 Install IP 920 on 19 rack using two pan head screws M5 ...

Страница 36: ...Chapter 2 Installation and Connection IP 920E DC 22 7 Install the mounting kit C on IP 920 using two pan head screws M5 Removing the device Remove the device by reversing the installation procedure ...

Страница 37: ...stallation and Connection IP 920E DC 23 1 unit per 1U Type B1 1 Check components of the rack mounting kit 2 Check all cables disconnected 3 Install the rack mounting kit A on IP 920 using three same screws M4 B A C ...

Страница 38: ...er 2 Installation and Connection IP 920E DC 24 4 Install the rack mounting kit B on IP 920 using three same screws M4 5 Install the rack mounting kit C on IP 920 and rack mounting kit B using four screws M4 ...

Страница 39: ...Chapter 2 Installation and Connection IP 920E DC 25 6 Install IP 920 on 19 rack using four pan head screws M5 Removing the device Remove the device by reversing the installation procedure ...

Страница 40: ...ype B2 1 Check contents of the rack mounting kit 2 Check all cables disconnected 3 Connect the first device with the connecting kit using six same screws M4 4 Connect the second device with the connecting kit using six same screws M4 Coupling fittings Mounting fittings ...

Страница 41: ...Chapter 2 Installation and Connection IP 920E DC 27 5 Rotate the connecting kit and fix with twelve screws M4 Bottom view Top view ...

Страница 42: ...d Connection IP 920E DC 28 6 Install the mounting kit on 2 units using six same screws M4 7 Install 2 units on 19 rack using four pan head screws M5 Removing the device Remove the device by reversing the installation procedure ...

Страница 43: ...2 2 Environment Specifications The consideration for adjustment of the air condition like air circulation should be given to prevent the internal rack ambient from exceeding the maximum operating ambient temperature of IP 920E DC The maximum operating ambient temperature for IP 920E DC 55 C MODEL PART NO IP 920E DC TA23742 B72X This device complies with Part 15 of the FCC Rules operation is subjec...

Страница 44: ...IP 920E DC into rack Do not install IP 920E DC into your rack where IP 920E DC may make the entire rack unstable The weight of IP 920E DC with the maximum configuration 2 3 kg d When using a bracket for mounting two products and you remove one product do not leave the remaining one that is fixed at one end only unattended If you apply pressure to a product that is supported at one end only it may ...

Страница 45: ...0E DC 31 2 1 4 Open space required around this equipment Provide the indicated parts with hatched area below cable forming space operation space and air intake exhaust For the information of maintenance space see Section 5 3 1 Maintenance space ...

Страница 46: ... ground and power source connections 2 2 1 Connection to ground When the exogenous noise influences IP 920E DC connect the FG terminal to an external ground FG terminal M4 Figure Connection to ground RDY PWR ALM IN DWN OPT MNT FG ACT 100M LINK 10 100BASE RS 232C ANALOG VIDEO IN SDI ANALOG AUDIO IN 12 24V E 2 2 ...

Страница 47: ...C power cable In case of using non attached power cable select a power cable referring to 9 in 4 2 Cable Connector Details Also power cable can be ordered separately with your suitable length Reference DC power cable 3m TA77057 3000 normally attached DC power cable length specification TA77057 xxxx Maximum length 3m TA77057 0500 is 0 5m TA77057 2000 is 2m Figure Power cord connection RDY PWR ALM I...

Страница 48: ...n below This indicates a hazardous situation that could lead to electric shock fire or damage to this equipment Use a DC power cable attached to IP 920E DC If the attached power cable is unusable select a power cable referring to 9 in 4 2 Cable and Connector Details Use a power supply unit outputting DC12 24V with a power consumption of more than 40W ...

Страница 49: ...NC cable with NTSC or PAL signal 2 Digital and 1analog audio input connectors are equipped for connecting with audio output equipment Digital Audio Input SDI Embedded Audio and HDMI audio are supported Analog Audio Input Connect to ANALOG AUDIO IN connector of IP 920E using the audio adaptor cable The figure of cable connections are shown below For details about connectors and cables see Section 4...

Страница 50: ...onnectors and cables see Section 4 2 Cable and Connector Details For electrical specifications see Appendix 2 3 Function Specifications Figure Connection to a network Please do not provision the IP address below IP address commonly unused 0 0 0 0 255 255 255 255 etc Loop back address 127 xxx xxx xxx Class D and Class E addresses IP address already used For more information see IP 920E DC Software ...

Страница 51: ...esponding to the connected device See Section 4 2 Cable and Connector Details The figure below shows the connection method For details about connectors and cables see Section 4 2 Cable and Connector Details For electrical specifications see Appendix 2 3 Function Specifications Figure Connection to RS 232C input output device RDY PWR ALM IN DWN OPT MNT FG ACT 100M LINK 10 100BASE RS 232C ANALOG VID...

Страница 52: ... can be procured separately depending on the system The CF card removal procedure is shown below Please turn off the power to insert or remove the CF card Please contact Fujitsu office what type of CF card is available to use 1 Check if the power is OFF 2 Screw out Eject button CF card 4 Press the eject button and remove the CF card CF card is unequipped initially Separate order 5 Replace CF card ...

Страница 53: ...on Please note that you need to remove the CF card or take the backup of its recorded data in case of requesting the repair of the main unit that the CF card is installed since Fujitsu does not guarantee the recorded content during the repair work Please also note that the recorded content might be deleted by the process of the diagnostic and the repair work after Fujitsu starts the work even if y...

Страница 54: ......

Страница 55: ... Instructions This section explains how to power on off setup and operate this equipment 3 1 Turn ON OFF IP 920E DC 43 3 2 Device Settings and Operation 44 3 3 Special Use of MNT Button 46 CHAPTER 3 OPERATION INSTRUCTIONS ...

Страница 56: ... This page is intentionally left blank ...

Страница 57: ...When the power button on the front panel is set to the O position this equipment is turned off and the PWR LED turns off This indicates the on switch which is used to supply power to the IP 920E DC This indicates the off switch which is used to disconnect power from the IP 920E DC RDY PWR ALM IN DWN OPT MNT FG ACT 100M LINK 10 100BASE RS 232C ANALOG VIDEO IN SDI ANALOG AUDIO IN 12 24V E RDY PWR AL...

Страница 58: ...20E DC is disconnected to user s network Connect using UTP cable When connect through LAN port the default IP address and subnet mask are 10 0 0 1 and 255 0 0 0 respectively Assign 10 xxx xxx xxx for PC ex IP address 10 0 0 2 Subnet mask 255 0 0 0 for PC For details please refer to the Software User s Guide Turn ON IP 920E DC Execute the Network setting from WEB GUI after the device starts For det...

Страница 59: ...briefly explains the basic functions of the setup pages 3 2 1 Reboot Clicking the button displayed in the left frame of the browser reboots this equipment When you click the button the following dialog box shown below appears for confirmation Click OK to reboot ...

Страница 60: ...ace 1 1 When you operate the IP 920E DC with the default IP address connect this equipment to a control terminal and make setting from the terminal with this equipment disconnected from your network After making settings according to the requirements for your network connect this equipment to the network If this equipment with the default settings made at the factory is connected to the network an...

Страница 61: ...ications This chapter contains a type of how work is implemented cable connection system diagrams and cable connector details 4 1 Installation Preparations 49 4 2 Cable and Connector Details 50 CHAPTER 4 CABLE SPECIFICATIONS ...

Страница 62: ... This page is intentionally left blank ...

Страница 63: ... 4 1 8 DC Power cable IP 920E DC External device D sub9 1 XLR cable 2 XLR cable 232C INPUT DC 12 24V 5 RS 232C cable SDI ANALOG AUDIO Analog audio output device mic etc IN 3 Coaxial cable BNC IN IN ANALOG VIDEO 4 Coaxial cable BNC IN HDMI 6 HDMI cable HDMI RJ45 7 LAN cable LAN 10 100BASE Power source DC 12 24V SELV Output Device with RS 232C interface Digital video HD SD SDI output device incld em...

Страница 64: ... DC External device Front view NTSC Connector Order Pin assignment Maximum length 200m Coaxial cable 75Ω 3C 2T 30m Coaxial cable 75Ω 3C 2T Color Mono Coaxial cable 75Ω 5C FB or more BNC BNC SIGNAL SG SIGNAL SG HD SDI 100m Coaxial cable 75Ω 5C FB or more 1 2 Front view Connector Order Pin assignment Maximum length Coaxial cable with BNC connector Product code TBD IP 920E DC External device SD SDI 1...

Страница 65: ...cable Front view Audio cable 1 2 XLR Male 20m Front view Connector Order Pin assignment Maximum length OR 3 IP 920E DC External device XLR Male XLR Female XLR Male XLR Female XLR Female XLR Female XLR Male OR Audio cable with XLR male connector Product code TBD ...

Страница 66: ...Chapter 4 Cable specifications IP 920E DC 52 4 AUDIO Adapter cable 1 3 ...

Страница 67: ... CLOCK TMDS CLOCK SHIELD TMDS CLOCK CEC RESERVE N C SCL SDA DDC CEC GROUND 5V POWER HOT PLUG DETECT TMDS DATA2 TMDS DATA2 SHIELD TMDS DATA2 TMDS DATA1 TMDS DATA1 SHIELD TMDS DATA1 TMDS DATA0 TMDS DATA0 SHIELD TMDS DATA0 TMDS CLOCK TMDS CLOCK SHIELD TMDS CLOCK CEC RESERVE N C SCL SDA DDC CEC GROUND 5V POWER HOT PLUG DETECT Length of the attested HDMI cable is pretermission The unattested cable can ...

Страница 68: ...D sub9 Female 4 40 retainer screw SG DSR DR RTS RS CTS CS CD RD SD DTR ER RI SG DSR DR RTS RS CTS CS CD RD SD DTR ER RI IP 920E DC DTE RS 232C DCE External device DCE D sub 9 pin female 01 02 03 04 05 06 07 08 09 SG DSR DR RTS RS CTS CS CD RD SD DTR ER RI SG DSR DR RTS RS CTS CS CD RD SD DTR ER RI 15 m Twisted pair cable with shield 24AWG Connector Pin assignment Maximum length Pin assignment IP 9...

Страница 69: ...ore 10 100BASE order Connector Pin assignment Max length Front view IP 920E DC External device RJ45 RJ45 IP 920E DC External device 5m TPCBL B005 10m TPCBL B010 50m TPCBL B050 100m TPCBL B100 IP 920E DC External device TD TD RD RD TD TD RD RD TD TD RD RD TD TD RD RD 10 100BASE Straight connection ...

Страница 70: ...h it depends on the opposite device select a plug of more than 5A allowable current and more than 60V nominal voltage If you need a specialized tool when making a cable ensure to use the matching item from the same maker as the plug s maker Please refer to the next page for the method of wire connection with IP 920E DC connector Order Connector Pin assignment Front view XLR Male IP 920E DC Externa...

Страница 71: ...216P 4S 72 5 6mm 1 Remove the insulation about 5 6 mm 2 Put the shell and the bushing together 3 Pass the cable through the hole 4 Solder the pin Pin 1 Pin 2 N C Pin 3 N C Pin 4 5 Build it into the shell 6 Screw down the barrel 7 Screw down the clamp The bigger bore is for IP 920 side Screw clamp x 2 IP 920E DC side Cable side ...

Страница 72: ... This page is intentionally left blank ...

Страница 73: ...power on off setup and operate this equipment This chapter describes actions to be taken if this equipment does not operate normally or if an alarm LED turns on 5 1 Help Information 61 5 2 Alarm LED Lamp Is On 65 5 3 Maintenance 67 CHAPTER 5 TROUBLESHOOTING ...

Страница 74: ... This page is intentionally left blank ...

Страница 75: ...shown Check alarm code using log information screen of Web GUI The countermeasures are shown E013 Temperature warning Check whether the condition is satisfied with 2 1 Installation Conditions or not Do you secure certain space for air supply and exhaust opening Is ambient temperature within the condition In case of having problems in the conditions above reboot the equipment after excluding the al...

Страница 76: ...t matched with video output device such as camera this device correctly connected to the video audio output device e g Although this equipment is set as 59 94Hz the output device was set as 50Hz by mistake Check whether the format is set to the using video audio format for this equipment and output device or not 12 No images can be output on the receiving device black screen Is the monitor which c...

Страница 77: ... output signal is bigger or smaller than the normal range Check this equipment connected 28 When AGC setting of encoder change ON or OFF the video contents does not improve normal Encoder is working normal The iris adjustment of the camera is possibly necessary 29 The video contents look dark When AGC setting of encoder change ON or OFF the video contents improve normal Encoder is working normal I...

Страница 78: ...on the control terminal 41 Are the network settings IP address subnet mask etc on the control terminal PC correct Make correct settings by referring to the PC user s guide and OS handbook If this device is started with the default settings made before shipment from the factory refer to Section 3 2 Device Settings and Operation for the network settings for the control terminal PC 42 Is a reply rece...

Страница 79: ...nfiguration Check IPV6 router and the related settings of this equipment and whether the router works correctly or not Ixxx This alarm is related with input status Each INDWN LED IP 920E and DEC LED IP 920D is turned on or blinked Each code s description and the countermeasures are shown below If an error cannot be identified or recovered contact your system administrator or Fujitsu CE I001 No SDI...

Страница 80: ...or decoder ALM Alarm LED Blinks or lights in orange when a device alarm occurs For more details of the alarm log refer to Section 3 2 7 Log of IP 920E IP 920D Software User s Guide OPT Lights in green when the HD upgrade option is installed 100M Turns on in green if the connected LAN is 100BASE TX Turns off if the connected LAN is 10BASE T LINK ACT Indicates the LAN connection status and data send...

Страница 81: ...d around this equipment Desk top installation Please allocate the space more than 1 m in front or rear for maintenance Rack installation Please allocate the space more than 1 m in front and rear for maintenance Front access case Rear access case Rear space for maintenance 700mm 1000mm Front space for maintenance 700mm 1000mm 5 3 Front space for maintenance 700mm 1000mm Rear space for maintenance 7...

Страница 82: ...re might be failure Change hardware as below The equipment itself is regarded as repair unit When you regarded it as failure please change the equipment In case that the optional CF card is installed in the main unit please do not forget to remove it and re install in the replaced unit Please refer to Section 2 6 CF card insertion and removal for the respective maintenance CF CARD ACT RDY PWR ALM ...

Страница 83: ...its main specifications Notes on installation work and preparations for on site turn up are also contained in this section A 1 Appearance 71 A 2 Basic Specifications 73 A 3 Preparations for Installation Work 79 A 4 Preparations for On site Turn up 80 Appendix ...

Страница 84: ... This page is intentionally left blank ...

Страница 85: ...Appendix IP 920E DC 71 A 1 Appearance The appearance of IP 920E DC is shown below A 1 ...

Страница 86: ...n MADE IN JAPAN 3 2A 1 6A 12V 24V 2 3kg FUJITSU LIMITED T 認証番号 01A 11 03 00001 D08 0454001 00001 I T E ACCESSORY LISTED R C US 1K91 E136004 MODEL PART NO IP 920E DC TA23742 B72X This device complies with Part 15 of the FCC Rules operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including int...

Страница 87: ...ifications Item Specifications Power conditions DC 12 24V 10 Temperature and humidity conditions Temperature 10 to 55 C No low temperature startup 10 to 1 C Humidity 20 to 90 without condensation Conditions for guaranteed operation and characteristics Dust Communication equipment room or office environment 0 15 mg m3 or less Gaseous contamination In accordance to IEC 60721 3 3 Class 3C1 Sulphur di...

Страница 88: ...arks Analog VIDEO input Signal format NTSC Analog composite 29 97frames s PAL Analog composite 25frames s Input impedance 75Ω Unbalanced Signal amplitude 1 0 Vp p Maximum amplitude level 0 5dB 0dB 100IRE Permissible cable length 30m 3C 2T or equivalent Connector name ANALOG VIDEO IN BNC Pin number Signal name Remarks 2 1 1 2 SIGNAL SG Name Specifications Remarks Analog AUDIO input Signal format An...

Страница 89: ...bit s 5000ppm 0 005 Load impedance 100Ω Transmission coding 4B5B Connector name 10 100 BASE RJ 45 Pin number Signal name Remarks 1 2 3 4 5 6 7 8 TD TD RD N C N C RD N C N C Transmission data Transmission data Receive data Receive data Cable Standard ANSI TIA EIA568A CAT5 Pin assignment Comply with one of two below Pin No 1 2 3 4 5 6 7 8 T568A W G G W O Bl W Bl O W Br Br T568B W O O W G Bl W Bl G W...

Страница 90: ...le Pin number Signal name Remarks 1 2 3 4 5 6 7 8 9 CD RD SD DTR ER SG DSR DR RTR RS CTS CS RI Carrier Detect Receive Data Send Data Data Terminal Ready Signal Ground Data set Ready Request to Send Clear to Send Ring Indicator Name Specifications Remarks POWER Input voltage Connector Button Input protection Withstand voltage 12 24V DC 10 4Pin XLR Connector Locker button Built in fuse DC500 V Conne...

Страница 91: ...nattested cable can t be used DVI isn t supported Connector name HDMI IN HDMI 19 pin Type A Pin number Signal name Remarks 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 TMDS DATA2 TMDS DATA2 SHIELD TMDS DATA2 TMDS DATA1 TMDS DATA1 SHIELD TMDS DATA1 TMDS DATA0 TMDS DATA0 SHIELD TMDS DATA0 TMDS CLOCK TMDS CLOCK SHIELD TMDS CLOCK CEC RESERVE N C SCL SDA DDC CEC GROUND 5V POWER HOT PLUG DETECT No 18...

Страница 92: ...arm Temperature alarm CF card access error IP address acquisition failure Normal operation IN DWN O Video input down fault Reference clock slipping Reference clock input down fault Normal operation HD SDI video input or reference clock input monitoring LINK ACT LAN G LINK established LAN packets detection Cable disconnection or software inactive 100M G 100BASE operation 10BASE operation OPT G HD o...

Страница 93: ... package A 3 3 Installation conditions For the classification of this work see Section 2 1 Installation Conditions The installation method may differ depending on the site where this equipment is installed In principle the installation method conforms to the appropriate method for the site Do not install this equipment at the following locations Place exposed to direct sunlight or near a heater Hu...

Страница 94: ...f this equipment are diverse depending on the applications used this chapter describes the checking process for only a single device A 4 START 準備 環境確認 員数確認 版数確認 外観目視確認 ケーブル接 続 入力電圧確認 電源投入 単体試験 システム試験 EN D Preparations Environment check Visual check of appearance Cable connection check Input voltage check Turn on Unit test System test END START ...

Страница 95: ... power source equipment supports SELV safety status 3 Visual check of appearance 1 Check this equipment surface has no damage such as scratches dirt rust deformation or peeling of its coating 2 Check the patent nameplate and device nameplate are still attached and that buttons are not damaged 3 Check the connectors are not loose 4 Cable connection check Check the individual cables are connected as...

Страница 96: ...all appropriate software following IP 900 Series Software User s Guide 2 Set up check Various devices settings complying with the system specification are made from the control terminal either directly or via the network 3 Input video check Check the video input to this equipment is correctly output to the monitor television 4 Data communication check Check the line used by the system is connected...

Страница 97: ...Glossary and Index Glossary 85 Index 88 CE Conformity Information 90 Glossary and Index ...

Страница 98: ... This page is intentionally left blank ...

Страница 99: ...AES EBU digital audio signals in the auxiliary data area blanking area of the serial digital signal FG Frame Ground Ground for a cabinet Flow Control Procedure for controlling the flow of data between two devices Its purpose is to prevent data loss when this equipment buffer becomes full Gateway Equipment that connects network systems that use different protocols It basically converts one protocol...

Страница 100: ... graphics and text It defines a flexible framework for a scalable object encoding system depending on technological developments It has a transfer speed ranging from several tens of Kbps to several tens of Mbps low bit rate to wide range It is intended for low speed communication by general purpose multimedia encoding systems on mobile terminals PING A command supported by operating systems such a...

Страница 101: ...saction protocol used for specific applications such as remote network management and naming service access Unicast Communication with a station at a single address i e most general one to one communication UTP Cable Abbreviation of unshielded twisted pair It is a unshielded pair of wires twisted together and these wires are used for Ethernet cabling and other purposes 10BASE T LAN that uses unshi...

Страница 102: ...necting external cables 73 Connection to an RS 232C device 32 Connection to ground 27 Connection to network 31 Connection to power source 28 Cooling method 67 Cooling system 3 D Data input output 3 Data interface 70 DC power cord 50 Device settings and operation 38 Dimensions 3 67 Dust 67 E Environment specifications 67 External specifications 67 F FG terminal 7 Function specifications 68 G Glossa...

Страница 103: ...Powering off 37 Powering on 37 Preparation for installation work 73 Preparations 1 Preparations for On site Turn up 74 R RS 232C 7 32 RS 232C cable 48 RS 232C interface 70 RS 232C port 7 S Scope of installation work 73 SDI VIDEO cable 44 SD SDI 30 Setup operations 38 Special Use of Cancel Key 40 Status LED 6 T Temperature 3 67 Troubleshooting 53 U Unpacking and device check 73 UTP cable 31 V Video...

Страница 104: ...and Index IP 920E DC 90 90 CE Conformity Information Following address can be reached at for regarding the CE conformity information Fujitsu Services Limited Address 22 Baker Street London W1U 3BW United Kingdom ...

Страница 105: ...IP 920E DC Hardware User s Guide Edition 8 June 2016 FUJITSU LIMITED If this manual is missing a page or pages are not in the proper order it will be replaced ...

Страница 106: ......

Отзывы: