Chapter 2 Installation and Connection
IP-920E/DC
11
2.1
Installation Conditions
This section describes the installation environment, space and air supply and exhaust of the
equipment.
2.1.1 Environment conditions
Please use this equipment in the air supply and ambient temperature which is not exceeded 55
degrees C. If the condition above is observed, you may install plural equipment as piling on a shelf.
In case of using this equipment under unsupported conditions, the equipment cannot be supported
by Fujitsu and it might be the cause of failure and shortening the product life remarkably.
Use this Equipment in the environment which airborne dust is under 0.15mg/m3. (In case of being
over 0.15mg/m3, use dust-proofing rack.) In addition, clean up around this equipment because
remarkably amount of dust is the cause of equipment errors and failures if it is attached to the
equipment.
Use this Equipment in the environment which gaseous contamination is under “IEC 60721-3-3
Class 3C1”.(Refer to “Appendix 2.2 Environment Specifications - Gaseous contamination”).
2.1.2 Installation environment
1. 19” rack mounting
Mount this equipment to 19
”
rack of EIA standard using the 19
”
rack mounting kit. We have 2
types of mounting kits; 1 unit per 1 U and 2 units per 1U.
(19
”
rack mounting kit is an optional product.)
If you would like to mount different way from the descriptions in this document, please
consult Fujitsu Service Center or your system administrator.
5 types of rack mounting kit are available. (Type A1, A2, B1, B2 and C2)
Use attached mounting kit and screws for installing equipment. Fix the
equipment tightly with the attached rack using attached screws. In case of
loosening the screws or not being fixed tightly with the equipment, it may be
a cause of serious accident.
2.1
Содержание IP-920 E/DC
Страница 1: ...IP 920E DC Hardware User s Guide ...
Страница 2: ... This page is intentionally left blank ...
Страница 16: ... This page is intentionally left blank ...
Страница 22: ... This page is intentionally left blank ...
Страница 35: ...Chapter 2 Installation and Connection IP 920E DC 21 6 Install IP 920 on 19 rack using two pan head screws M5 ...
Страница 54: ......
Страница 56: ... This page is intentionally left blank ...
Страница 62: ... This page is intentionally left blank ...
Страница 66: ...Chapter 4 Cable specifications IP 920E DC 52 4 AUDIO Adapter cable 1 3 ...
Страница 72: ... This page is intentionally left blank ...
Страница 74: ... This page is intentionally left blank ...
Страница 84: ... This page is intentionally left blank ...
Страница 85: ...Appendix IP 920E DC 71 A 1 Appearance The appearance of IP 920E DC is shown below A 1 ...
Страница 97: ...Glossary and Index Glossary 85 Index 88 CE Conformity Information 90 Glossary and Index ...
Страница 98: ... This page is intentionally left blank ...
Страница 106: ......