En-2

  

Ensure that any electronic equipment is at least 3.3 ft (1m) away from either the indoor or outdoor units.

 

Avoid installing the air conditioner near a fi replace or other heating apparatus.

 

When installing the indoor and outdoor unit, take precautions to prevent access to infants.

 

Do not use infl ammable gases near the air conditioner.

  This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not play with the appliance.

CAUTION!

FEATURES AND FUNCTIONS

FEATURES AND FUNCTIONS

INVERTER

At the start of operation, large amount of power is used to 
bring the room quickly to the desired temperature. Afterwards, 
the unit automatically switches to a low power setting for eco-
nomic and comfortable operation.

WIRELESS REMOTE CONTROLLER

The Wireless Remote Controller allows convenient control of 
air conditioner operation.

ECONOMY OPERATION

When ECONOMY operation mode is operated, the room tem-
perature will be little higher than the set-temp under cooling 
mode and lower than set-temp under heating mode. Therefore, 
the ECONOMY mode is able to save more energy than other 
normal mode.

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched auto-
matically to maintain the set temperature, and the temperature 
is kept constant at all times.

MINIMUM HEAT OPERATION

The room temperature can be maintained at 50°F so as to pre-
vent the room temperature from falling too far.

PROGRAM TIMER

The program timer allows you to integrate OFF timer and ON 
timer operations in a single sequence. The sequence can in-
volve 1 transition from OFF timer to ON timer, or from ON timer 
to OFF timer, within a 24 hour period.

SLEEP TIMER

When the SLEEP button is pressed during Heating mode, the 
air conditioner’s thermostat setting is gradually lowered during 
the period of operation; during cooling mode, the thermostat 
setting is gradually raised during the period of operation. When 
the set time is reached, the unit automatically turns off.

HORIZONTAL AIRFLOW: COOLING/
DOWNWARD AIRFLOW: HEATING

For cooling, use horizontal airfl ow so the cool air does not blow 
directly on the occupants in the room. For heating, use down-
ward airfl ow to send powerful, warm air to the fl oor and create 
a comfortable environment.

OMNI-DIRECTIONAL AIRFLOW
(SWING OPERATION)

3-dimensional control over air direction swing is possible through 
dual use of both an UP/DOWN air direction swing and RIGHT/LEFT 
air direction swing. Since UP/DOWN air direction fl aps operate au-
tomatically according to the operating mode of the unit, it is possible 
to set air direction based on the operating mode.

REMOVABLE INTAKE GRILLE

The indoor unit’s INTAKE GRILLE can be removed for easy 
cleaning and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth, 
thus allowing cleaner use and easier care.

SUPER QUIET OPERATION

When the FAN button is used to select QUIET, the unit begins 
super-quiet operation; the indoor unit’s airflow is reduced to 
produce quieter operation.

POLYPHENOL CATECHIN AIR CLEANING FILTER

The polyphenol catechin air cleaning fi lter uses static electric-
ity to clean fi ne particles and dust in the air such as tobacco 
smoke and plant pollen that are too small to see.
The fi lter contains catechin, which is highly effective against 
various bacteria by suppressing the growth of the bacteria ad-
sorbed to the fi lter.
Note that when the air cleaning fi lter is installed, the amount 
of air produced decreases, causing a slight decrease in the 
indoor unit’s performance.

NEGATIVE AIR IONS DEODORIZING FILTER

It comprises pottery super micro particles which can produce 
negative air ions having the effect of deodorizing and can ab-
sorb and remit the peculiar smell at home. 

9315345295-03_OM_EN.indd   2

9315345295-03_OM_EN.indd   2

2010-9-3   15:09:48

2010-9-3   15:09:48

Содержание Inverter Halcyon

Страница 1: ...PART NO 9315345295 03 Wall Mounted Type ...

Страница 2: ...se Do not direct airflow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power supply when not using the...

Страница 3: ...a 24 hour period SLEEP TIMER When the SLEEP button is pressed during Heating mode the air conditioner s thermostat setting is gradually lowered during the period of operation during cooling mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off HORIZONTAL AIRFLOW COOLING DOWNWARD AIRFLOW HEATING For cooling use h...

Страница 4: ... facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 2 Fig 3 Fig 4 ...

Страница 5: ...IMER Display Z Transmit Indicator Fan Speed Display SWING Display Timer Mode Display Clock Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the force...

Страница 6: ...arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 S Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 R to adjust the clock to the current time button Press to advance the time button Press to rever...

Страница 7: ... FAN button Fig 5 L Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature ...

Страница 8: ...hich it will switch to the se lected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERA...

Страница 9: ...timer and ON timer See the section To Use the ON timer or OFF timer to set the desired mode and times About 3 seconds later the entire display will reappear The indoor unit s TIMER Indicator Lamp orange Fig 3 6 will light 3 Press the TIMER MODE button Fig 5 K to select the PROGRAM timer operation OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to ...

Страница 10: ... Operation Press the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in ac cordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automati cally raised 2 ...

Страница 11: ...aking settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 5 N Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 4 5 6 During Heating Cooling Dry modes The Remote Controller s display does not change Use the air direction adjustments within the ranges shown above The vertical airflow directio...

Страница 12: ...under heating mode Therefore the ECONOMY mode is able to save more energy than other normal mode In case of multi type air conditioner the ECONOMY operation mode is only available for the set indoor unit Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation U...

Страница 13: ...far While MINIMUM HEAT OPERATION is in progress only the following operation can be used SWING SWING SLEEP How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 more than 3 seconds and less than 10 seconds on the main unit control panel To stop operation press the MANUAL AUTO button Fig 2 2 once again Controls are located inside the intake grille MANUAL AUTO OPERATION Use the MANU...

Страница 14: ...of the air filter with the panel and push in fully making sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit with out Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild deter gent and warm water If you wash ...

Страница 15: ...e disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy designed air cleaning filters UTR FA13 1 Sold separately to exchange the used d...

Страница 16: ... authorized serviceman when using this function It lights on when it is time to clean the air filters Clean the filter referring to CLEANING AND CARE After cleaning press the MANUAL AUTO button Fig 2 2 for 2 seconds or less on the indoor unit OPERATION Indicator Lamp Flashing OFF TIMER ECONOMY CLEANING AND CARE ...

Страница 17: ...emitted During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation 17 Airflow is weak or stops W...

Страница 18: ...ce personnel Operation and Performance Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat to indoor unit As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction wit...

Страница 19: ...that they be used in conjunction with other auxiliary space heaters as required Seasonal and outdoor temperature conditions the struc ture of the rooms and the number of persons present may also result in differences of operating efficiency We rec ommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in t...

Страница 20: ......

Отзывы: