CAUTION

Read carefully all security information before use or install the air conditioner.

Do not attempt to install the air conditioner or a part of the air conditioner by yourself.

This unit must be installed by qualified personnel with a capacity certificate for handling 

refrigerant fluids. Refer to regulation and laws in use on installation place.

The installation must be carried out in compliance with regulations in force in the place 

of installation and the installation instructions of the manufacturer.

This unit is part of a set constituting an air conditioner. It must not be installed alone or 

with non-authorized by the manufacturer.

Always use a separate power supply line protected by a circuit breaker operating on all 

wires with a distance between contact of 3mm for this unit.

The unit must be correctly grounded and the supply line must be equipped with a 

differential breaker in order to protect the persons.

The units are not explosion proof and therefore should not be installed in explosive 

atmosphere.

Never touch electrical components immediately after the power supply has been turned 

off. Electric shock may occur. After turning off the power, always wait 5 minutes before 

touching electrical components.

This unit contains no user-serviceable parts. Always consult authorized service 

personnel to repairs.

When moving, consult authorized service personnel for disconnection and installation of 

the unit.

This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety. Children should be supervised to ensure that they do 

not play with the appliance.

2.  ABOUT THE UNIT

2.1. Precautions for using the R410A refrigerant

 

WARNING

Do not introduce any substance other than the prescribed refrigerant into the 

refrigeration cycle. 

If air enters the refrigeration cycle, the pressure in the refrigeration cycle will become 

abnormally high and cause the piping to rupture.

If there is a refrigerant leakage, make sure that it does not exceed the concentration 

limit. 

If a refrigerant leakage exceeds the concentration limit, it can lead to accidents such as 

oxygen starvation.

Do not touch refrigerant that has leaked from the refrigerant pipe connections or other 

area. Touching the refrigerant directly can cause frostbite.

If a refrigerant leakage occurs during operation, immediately vacate the premises and 

thoroughly ventilate the area.

If the refrigerant comes in contact with a 

fl

 ame, it produces a toxic gas.

2.2. Special tool for R410A

 

WARNING

To install a unit that uses the R410A refrigerant, use dedicated tools and piping 

materials that have been manufactured speci

fi

 cally for R410A use. 

Because the pressure of the R410A refrigerant is approximately 1.6 times higher than 

the R22, failure to use dedicated piping material or improper installation can cause 

rupture or injury. 

Furthermore, it can cause serious accidents such as water leakage, electric shock, or 

fi

 re.

Tool name

Contents of change

Gauge manifold

 Pressure is huge and cannot be measured with a conventional 
gauge. To prevent erroneous mixing of other refrigerants, the 
diameter of each port has been changed.
It is recommended to use a gauge manifold with a high pressure 
display range –0.1 to 5.3 MPa and a low pressure display range 
–0.1 to 3.8 MPa.

Charging hose

To increase pressure resistance, the hose material and base 
size were changed.

Vacuum pump

A conventional vacuum pump can be used by installing a 
vacuum pump adapter.

Gas leakage 

detector

Special gas leakage detector for HFC refrigerant R410A.

1. SAFETY PRECAUTIONS

•  Be sure to read this Manual thoroughly before installation.
•  The warnings and precautions indicated in this Manual contain important information 

pertaining to your safety. Be sure to observe them.

•  Hand this Manual, together with the Operating Manual to the customer. 

  Request the customer to keep them on hand for future use, such as for relocating or 

repairing the unit.

WARNING

This mark indicates procedures which, if improperly performed, 
might lead to the death or serious injury of the user.

CAUTION

This mark indicates procedures which, if improperly performed, 
might possibly result in personal harm to the user, or damage to 
property.

 

WARNING

Request your dealer or a professional installer to install the indoor unit in accordance 
with this Installation Manual. An improperly installed unit can cause serious accidents 
such as water leakage, electric shock, or 

fi

 re. If the indoor unit is installed in disregard 

of the instructions in the Installation Manual, it will void the manufacturer’s warranty.

Do not turn ON the power until all work has been completed. Turning ON the power 
before the work is completed can cause serious accidents such as electric shock or 

fi

 re.

If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant 
comes in contact with a 

fl

 ame, it produces a toxic gas.

Installation work must be performed in accordance with national wiring standards by 
authorized personnel only.

Except for EMERGENCY, never turn off main as well as sub breaker of the indoor units 

during operation. It will cause compressor failure as well as water leakage. 

First, stop the indoor unit by operating the control unit, converter or external input 

device and then cut the breaker.

Make sure to operate through the control unit, converter or external input device.

When the breaker is designed, locate it at a place where the users cannot start and 

stop in the daily work.

Contents

1. SAFETY 

PRECAUTIONS 

..........................................................................................1

2. ABOUT 

THE 

UNIT 

.....................................................................................................1

2.1. Precautions for using the R410A refrigerant .......................................................1
2.2. Special tool for R410A ........................................................................................1
2.3. Accessories ........................................................................................................2
2.4. Optional parts .....................................................................................................2

3. INSTALLATION 

WORK 

.............................................................................................2

3.1. Selecting an installation location ........................................................................2
3.2. Installation dimension .........................................................................................3
3.3. Installation the unit ..............................................................................................3

4.

 

PIPE INSTALLATION ................................................................................................4
4.1. Selecting the pipe material .................................................................................4
4.2. Pipe requirement ................................................................................................5
4.3. Flare connection (Pipe connection) ....................................................................5
4.4. Installing heat insulation .....................................................................................6

5.  INSTALLING DRAIN HOSE .......................................................................................6

6. ELECTRICAL 

WIRING 

..............................................................................................7

6.1. Wiring system diagram .......................................................................................7
6.2. Connection cable preparation .............................................................................8
6.3. Connection of wiring ...........................................................................................8

7.  REMOTE CONTROLLER SETTING .........................................................................9

7.1. Installing the remote controller ...........................................................................9
7.2. Setting the DIP switches .....................................................................................9

8. FUNCTION 

SETTING..............................................................................................10

8.1. Turning on the power ........................................................................................10
8.2. Function setting ................................................................................................10
8.3. Static pressure characteristic ...........................................................................12
8.4. Special installation methods .............................................................................12

9. FRESH 

AIR 

INTAKE 

................................................................................................13

10. TEST RUN 

...............................................................................................................14

11. CHECK 

LIST 

............................................................................................................14

12.  OPTIONAL KIT INSTALLATION (OPTION) .............................................................14

13. CUSTOMER GUIDANCE 

........................................................................................15

14. ERROR CODES 

......................................................................................................15

INSTALLATION MANUAL

PART NO. 9379127035
INDOOR UNIT (Duct Type)

9379127035-02_IM.indb   Sec1:1

9379127035-02_IM.indb   Sec1:1

23/01/2013   16:25:40

23/01/2013   16:25:40

Содержание INDOOR UNIT (Duct Type) AIR CONDITIONER

Страница 1: ... Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir PART NO 9379127035 02 AIR...

Страница 2: ... prevent erroneous mixing of other refrigerants the diameter of each port has been changed It is recommended to use a gauge manifold with a high pressure display range 0 1 to 5 3 MPa and a low pressure display range 0 1 to 3 8 MPa Charging hose To increase pressure resistance the hose material and base size were changed Vacuum pump A conventional vacuum pump can be used by installing a vacuum pump...

Страница 3: ...portant for the split type air conditioner be cause it is very difficult to move from place to place after the first installation WARNING Select installation locations that can properly support the weight of the indoor Install the units securely so that they do not topple or fall CAUTION Do not install the unit in the following areas Area with high salt content such as at the seaside It will deter...

Страница 4: ... units and filter Maintenance hole Intake panel Control box Unit mm 3 3 Installation the unit WARNING Install the air conditioner in a location which can withstand a load do at least 5 times the weight of the main unit and which will not amplify sound or vibration If the installation location is not strong enough the indoor unit may fall and cause injuries If the job is done with the panel frame o...

Страница 5: ... the round flange and square flange when con necting the duct CAUTION Check that duct work does not exceed the range of external static pressure of equipment Make sure to insulate ducts to avoid the dew condensation Make sure to insulate between ducts and walls if metal ducts are used Please explain handling and washing methods of locally purchased materials to the customer To prevent people from ...

Страница 6: ...o 42 320 to 420 12 70 1 2 dia 49 to 61 490 to 610 15 88 5 8 dia 63 to 75 630 to 750 19 05 3 4 dia 90 to 110 900 to 1 100 Thicknesses of Annealed Copper Pipes R410A Pipe outside diameter mm in Thickness mm 6 35 1 4 0 80 9 52 3 8 0 80 12 70 1 2 0 80 15 88 5 8 1 00 19 05 3 4 1 20 4 2 Pipe requirement CAUTION Refer to the Installation Manual of the outdoor unit for description of the length of connect...

Страница 7: ...nd so there are no rises or traps in the hose Use general hard polyvinyl chloride pipe VP25 outside diameter 38 mm and connect it with adhesive polyvinyl chloride so that there is no leakage When the hose is long install supporters Do not perform air bleeding Always heat insulate the indoor side of the drain hose Outlet air flow Drain hose Trap Arrange the drain hose lower than this portion Rise A...

Страница 8: ...a earth leakage breaker In addition install the earth leakage breaker so that the entire AC main power supply is cut off at the same time Otherwise electric shock or fire could result Always connect the earth cable Improper grounding work can cause electric shocks Install the remote controller cables so as not to be direct touched with your hand Perform wiring work in accordance with standards so ...

Страница 9: ...t Check local electrical rules and also any specific wiring instructions or limitation 6 2 Connection cable preparation Keep the earth ground wire longer than the other wires Power supply cable or connection cable 20 mm 50mm or more Earth ground wire Use a 4 core wire cable 6 3 Connection of wiring CAUTION Use care not to mistake the power supply cable and connection wires when installing Remove t...

Страница 10: ...en installing the front case connect the connector to the front case Screws SET BACK Front case back side Rear case Connector When remote controller cable is concealed 1 Conceal the remote controller cable 2 Pass the remote controller cable through the hole in the rear case and connect the remote controller cable to the remote controller terminal board specified in figure 3 Clamp the remote contro...

Страница 11: ... SET button to confirm the setting Press the TIMER SET button for a few seconds until the setting value stops flashing If the setting value display changes or if is displayed when the flashing stops the setting value has not been set correctly An invalid setting value may have been selected for the indoor unit 6 Repeat steps 2 to 5 to perform additional settings Press the SET TEMP buttons and FAN ...

Страница 12: ...s remote controllers Factory setting Setting description Function number Setting value A 44 00 B 01 C 02 D 03 8 External input control Operation Stop mode or Forced stop mode can be selected Factory setting Setting description Function number Setting value Operation Stop mode 46 00 Setting forbidden 01 Forced stop mode 02 Setting record Record any changes to the settings in the following table Set...

Страница 13: ...main power 8 4 1 Group control system A number of indoor units can be operated at the same time using a single remote controller 1 Wiring method indoor unit to remote controller 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Indoor unit 1 Bus wire Remote controller cable Remote controller When ground wire is necessary Indoor unit 2 Indoor unit 3 Indoor unit 4 2 DIP switch setting Indoor unit Set the unit number of...

Страница 14: ...nnected the outdoor unit using a transmission cable is primary Connect the remote controller wire to the primary unit Twin type Outdoor unit Indoor unit Indoor unit Remote controller primary secondary DIP switch setting Indoor unit 2 Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board See the following table and figure The DIP switches are normally set t...

Страница 15: ...controller while the air conditioner is running Point the transmitter section of the wireless remote controller toward the air conditioner and press the TEST RUN button with the tip of a ball point pen etc Transmitter section TEST RUN button To end test operation press the wireless remote controller START STOP button When the air conditioner is run by pressing the TEST RUN button the OPERATION ind...

Страница 16: ...CB model information error 3 5 Manual auto switch error 4 1 Room temp sensor error 4 2 Indoor unit Heat Ex Middle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PC...

Отзывы: