En-3

10 °C HEAT OPERATION

The room temperature can be maintained at 10°C so as to 
prevent the room temperature from falling too far.

 

Convenient function

PROGRAM TIMER

The program timer allows you to integrate OFF timer and ON 
timer operations in a single sequence. The sequence can in-
volve 1 transition from OFF timer to ON timer, or from ON 
timer to OFF timer, within a 24 hour period.

SLEEP TIMER

When the SLEEP timer button is pressed during heating mode, 
the air conditioner’s thermostat setting is gradually lowered 
during the period of operation; during cooling or dry mode, 
the thermostat setting is gradually raised during the period of 
operation. When the set time is reached, the unit automatically 
turns off.

 

Clean function

REMOVABLE AIR FILTER

The indoor unit’s air 

fi

 lter can be removed for easy cleaning 

and maintenance.

FEATURES AND FUNCTIONS

 

Energy saving and Comfortable function

INVERTER

At the start of operation, large amount of power is used to 
bring the room quickly to the desired temperature. Afterwards, 
the unit automatically switches to a low power setting for 
economic and comfortable operation.

ECONOMY OPERATION

When ECONOMY operation mode is operated, the room 
temperature will be little higher than the set-temp under 
cooling mode and lower than set-temp under heating mode. 
Therefore, the ECONOMY mode is able to save more energy 
than other normal mode.

OMNI-DIRECTIONAL AIR FLOW 
(SWING OPERATION)

3-dimensional control over air direction swing is possible 
through dual use of both an up/down air direction swing and 
right/left air direction swing. Since up/down air direction 

fl

 aps 

operate automatically according to the operating mode of the 
unit, it is possible to set air direction based on the operating 
mode.

SUPER QUIET OPERATION

When the FAN button is used to select QUIET, the indoor 
unit begins super quiet operation; the indoor unit’s air

fl

 ow  is 

reduced to produce quieter operation.

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched auto-
matically to maintain the set temperature, and the temperature 
is kept constant at all times.

OM 01_9374379736-02_en.indd   3

OM 01_9374379736-02_en.indd   3

2/24/2559 BE   20:16

2/24/2559 BE   20:16

Содержание General ABG30UIA-LR

Страница 1: ...GEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA ХРАНИТЕ РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU İLERİDE BAŞVURMAK ÜZERE SAKLAYIN Português EλληvIkά Italiano Español Français Deutsch English Русский Tür...

Страница 2: ...k of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable ga...

Страница 3: ...he desired temperature Afterwards the unit automatically switches to a low power setting for economic and comfortable operation ECONOMY OPERATION When ECONOMY operation mode is operated the room temperature will be little higher than the set temp under cooling mode and lower than set temp under heating mode Therefore the ECONOMY mode is able to save more energy than other normal mode OMNI DIRECTIO...

Страница 4: ...button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling operation starts by any chance press the START STOP button to stop the operation Please press the button at Filter Reset 3 Remote control signal receiver...

Страница 5: ...ly If this button is pressed during normal operation the unit will switch to test run mode and the indoor unit s OPERATION indicator lamp and TIMER indicator lamp will begin to flash simultaneously To stop the test run press the START STOP button to stop the air conditioner F Signal transmitter G Temperature SET indicator H Operating mode indicator I SLEEP indicator J Transmit indicator K Fan spee...

Страница 6: ...hildren from accidentally swallowing the batteries CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Exhausted batteries must be removed immediately and be disposed according to the local laws and regulations of you...

Страница 7: ...peed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the fan speed becom...

Страница 8: ...ooling to adjust the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation HEAT COOL DRY FAN Cooling or Dry mode Defined temperature in temperature setting Heating mode Determined by outdoor temperature Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle During heating mo...

Страница 9: ... is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light 2 Set the desired times for OFF timer and ON timer Se...

Страница 10: ... minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During heating operation When the SLEEP timer is s...

Страница 11: ...remote controller Use the SET buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types of Airflow Direction Setting 1 2 3 During cooling dry modes 1 2 3 4 5 During heating mode The remote cont...

Страница 12: ...eeds To select up down swing operation ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green will go out Normal operation begins About ECONOMY Operation A...

Страница 13: ...us tom code other than custom code A reset the custom code after replacing the batteries If you do not know the air conditioner custom code setting try each of the custom codes until you find the code which operates the air conditioner Use the following steps to select the custom code of the remote controller Note that the air conditioner cannot receive a signal if the air conditioner has not been...

Страница 14: ...ights on when it is time to clean the air filters After turning the power on press the MANUAL AUTO button for 2 seconds or less on the indoor unit CLEANING AND CARE CAUTION When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized ser...

Страница 15: ... tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emit ted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner result ing in condensation and misting During heating operation the outdoor unit s fan may stop and steam may be seen rising from the u...

Страница 16: ...his air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recircu lating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of the heating ...

Страница 17: ...r can be added up to the maximum of 2 remote controllers Either remote controller can control the air conditioner However the timer functions cannot be used at the secondary unit Group Control 1 remote controller can control up to 16 air conditioners All of the air conditioners will be operated with the same settings The wired remote controller option is required to use the following function Duri...

Отзывы: