Fujitsu General ABG30UIA-LR Скачать руководство пользователя страница 13

En-13

To use 10 °C HEAT Operation

Press the 10 °C HEAT button.

The OPERATION indicator lamp (green) will go out, and the ECONOMY indicator lamp 
(green) will light.

While 10 °C HEAT operation is in 
progress, only the following 
operation can be used.
• 

 SWING

SELECTING THE REMOTE CONTROLLER CUSTOM CODE

When two or more air conditioners are installed in a room and the remote controller is operating an air conditioner other than the 
one you wish to set, change the custom code of the remote controller to operate only the air conditioner you wish to set (4 selections 
possible).
When two or more air conditioners are installed in a room, please contact your retailer to set the individual air conditioner custom 
codes.

Selecting the Remote Controller Custom Code

  If no buttons are pressed within 30 seconds after the custom code is displayed, the system returns to the original clock dis-

play. In this case, start again from step 1.

  The air conditioner custom code is set to “A” prior to shipment. Contact your retailer to change the custom code.

  The remote controller resets to custom code “A” when the batteries in the remote controller are replaced. If you use a cus-

tom code other than custom code “A”, reset the custom code after replacing the batteries.

 

If you do not know the air conditioner custom code setting, try each of the custom codes (

) until you 

fi

 nd the 

code which operates the air conditioner.

Use the following steps to select the custom code of the remote controller. (Note that 
the air conditioner cannot receive a signal if the air conditioner has not been set for the 
matching custom code.)

1

  Press the START/STOP button until only the clock is 

displayed on the remote controller display.

2

  Press the MODE button for at least 

fi

 ve seconds to 

display the current custom code (initially set to  ).

3

 Press 

the 

 

 

)

 buttons to change the custom code 

between 

. Match the code on the display to 

the air conditioner custom code.

4

  Press the MODE button again to return to the clock 

display. The custom code will be changed.

10 °C HEAT OPERATION

About the 10 °C HEAT Operation

• The heating mode will not operate if the room temperature is high enough.
• The room temperature can be maintained at 10 °C by pressing the 10 °C HEAT button  so as to prevent the room temperature from 

falling too far.

To stop 10 °C HEAT Operation

Press the START/STOP button.

Then the OPERATION stops and the ECONOMY indicator lamp (green) will go out.

OM 01_9374379736-02_en.indd   13

OM 01_9374379736-02_en.indd   13

2/24/2559 BE   20:16

2/24/2559 BE   20:16

Содержание General ABG30UIA-LR

Страница 1: ...GEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA ХРАНИТЕ РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU İLERİDE BAŞVURMAK ÜZERE SAKLAYIN Português EλληvIkά Italiano Español Français Deutsch English Русский Tür...

Страница 2: ...k of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable ga...

Страница 3: ...he desired temperature Afterwards the unit automatically switches to a low power setting for economic and comfortable operation ECONOMY OPERATION When ECONOMY operation mode is operated the room temperature will be little higher than the set temp under cooling mode and lower than set temp under heating mode Therefore the ECONOMY mode is able to save more energy than other normal mode OMNI DIRECTIO...

Страница 4: ...button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling operation starts by any chance press the START STOP button to stop the operation Please press the button at Filter Reset 3 Remote control signal receiver...

Страница 5: ...ly If this button is pressed during normal operation the unit will switch to test run mode and the indoor unit s OPERATION indicator lamp and TIMER indicator lamp will begin to flash simultaneously To stop the test run press the START STOP button to stop the air conditioner F Signal transmitter G Temperature SET indicator H Operating mode indicator I SLEEP indicator J Transmit indicator K Fan spee...

Страница 6: ...hildren from accidentally swallowing the batteries CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Exhausted batteries must be removed immediately and be disposed according to the local laws and regulations of you...

Страница 7: ...peed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the fan speed becom...

Страница 8: ...ooling to adjust the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation HEAT COOL DRY FAN Cooling or Dry mode Defined temperature in temperature setting Heating mode Determined by outdoor temperature Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle During heating mo...

Страница 9: ... is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light 2 Set the desired times for OFF timer and ON timer Se...

Страница 10: ... minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During heating operation When the SLEEP timer is s...

Страница 11: ...remote controller Use the SET buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types of Airflow Direction Setting 1 2 3 During cooling dry modes 1 2 3 4 5 During heating mode The remote cont...

Страница 12: ...eeds To select up down swing operation ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green will go out Normal operation begins About ECONOMY Operation A...

Страница 13: ...us tom code other than custom code A reset the custom code after replacing the batteries If you do not know the air conditioner custom code setting try each of the custom codes until you find the code which operates the air conditioner Use the following steps to select the custom code of the remote controller Note that the air conditioner cannot receive a signal if the air conditioner has not been...

Страница 14: ...ights on when it is time to clean the air filters After turning the power on press the MANUAL AUTO button for 2 seconds or less on the indoor unit CLEANING AND CARE CAUTION When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized ser...

Страница 15: ... tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emit ted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner result ing in condensation and misting During heating operation the outdoor unit s fan may stop and steam may be seen rising from the u...

Страница 16: ...his air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recircu lating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of the heating ...

Страница 17: ...r can be added up to the maximum of 2 remote controllers Either remote controller can control the air conditioner However the timer functions cannot be used at the secondary unit Group Control 1 remote controller can control up to 16 air conditioners All of the air conditioners will be operated with the same settings The wired remote controller option is required to use the following function Duri...

Отзывы: