Symptom

Problem

See page

CHECK ONCE

MORE

Does not operate at all:

  Has the circuit breaker been turned off?

  Has there been a power failure?

  Has a fuse blown out, or a circuit breaker been tripped?

  Is the timer operating?

9 to 10

Poor cooling (or heating*)

performance:

  Is the air 

fi

 lter dirty?

  Are the air conditioner’s intake grille or outlet port blocked?

  Did you adjust the room temperature settings (thermostat) 

correctly?

  Is there a window or door open?

  In the case of cooling operation, is a window allowing bright 

sunlight to enter? (Close the curtains.)

  In the case of cooling operation, are there heating apparatus 

and computers inside the room, or are there too many people 

in the room?

  Is the unit set for QUIET operation?

The unit operates differ-

ently from the remote con-

troller setting:

  Are the remote controller’s batteries dead?

  Are the remote controller’s batteries loaded properly?

6

If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION indicator lamp and the TIMER 
indicator lamp 

fl

 ashes, and ECONOMY indicator lamp 

fl

 ashes fast. Immediately stop operation, turn off the electrical breaker and consult 

authorized service personnel.

TROUBLESHOOTING

OPERATING TIPS

Heating Performance

*

  This air conditioner operates on the heat-pump principle, 

absorbing heat from outdoor air and transferring that heat 
indoors. As a result, the operating performance is reduced 
as outdoor air temperature drops. If you feel that insuf

fi

 cient 

heating performance is being produced, we recommend you 
use this air conditioner in conjunction with another kind of 
heating appliance.

  Heat-pump air conditioners heat your entire room by recircu-

lating air throughout the room, with the result that some time 
may be required after 

fi

 rst starting the air conditioner until the 

room is heated.

When Indoor and Outdoor Temperature are High

*

When both indoor and outdoor temperatures are high during use 
of the heating mode, the outdoor unit’s fan may stop at times.

Microcomputer-controlled Automatic Defrosting

*

  When using the heating mode under conditions of low outdoor 

temperature and high humidity, frost may form on the outdoor 
unit, resulting in reduced operating performance.

  In order to prevent this kind of reduced performance, this unit is 

equipped with a microcomputer-controlled automatic defrost-
ing function. If frost forms, the air conditioner will temporarily 
stop, and the defrosting circuit will operate brie

fl

 y (for about 

4 to 15 minutes).

  During automatic defrosting operation, the OPERATION 

indicator lamp (green) will 

fl

 ash.

  After heating operation stops, if frost forms on the outdoor 

unit, the unit will start automatic defrosting operation. At this 
time, the outdoor unit will automatically stop after operating 
for a few minutes.

Low Ambient Cooling

*

When the outdoor temperature drops, the outdoor unit’s fans 
may switch to low speed.

Hot Start (for heating)

*

The indoor unit prevents cold drafts when heating operation 
begins.
The indoor unit fan will not operate or it will operate at a very low 
speed until the heat exchanger reaches the set temperature. 

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

OM 01_9374379736-02_en.indd   16

OM 01_9374379736-02_en.indd   16

2/24/2559 BE   20:16

2/24/2559 BE   20:16

Содержание General ABG30UIA-LR

Страница 1: ...GEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA ХРАНИТЕ РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU İLERİDE BAŞVURMAK ÜZERE SAKLAYIN Português EλληvIkά Italiano Español Français Deutsch English Русский Tür...

Страница 2: ...k of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable ga...

Страница 3: ...he desired temperature Afterwards the unit automatically switches to a low power setting for economic and comfortable operation ECONOMY OPERATION When ECONOMY operation mode is operated the room temperature will be little higher than the set temp under cooling mode and lower than set temp under heating mode Therefore the ECONOMY mode is able to save more energy than other normal mode OMNI DIRECTIO...

Страница 4: ...button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling operation starts by any chance press the START STOP button to stop the operation Please press the button at Filter Reset 3 Remote control signal receiver...

Страница 5: ...ly If this button is pressed during normal operation the unit will switch to test run mode and the indoor unit s OPERATION indicator lamp and TIMER indicator lamp will begin to flash simultaneously To stop the test run press the START STOP button to stop the air conditioner F Signal transmitter G Temperature SET indicator H Operating mode indicator I SLEEP indicator J Transmit indicator K Fan spee...

Страница 6: ...hildren from accidentally swallowing the batteries CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Exhausted batteries must be removed immediately and be disposed according to the local laws and regulations of you...

Страница 7: ...peed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the fan speed becom...

Страница 8: ...ooling to adjust the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation HEAT COOL DRY FAN Cooling or Dry mode Defined temperature in temperature setting Heating mode Determined by outdoor temperature Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle During heating mo...

Страница 9: ... is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light 2 Set the desired times for OFF timer and ON timer Se...

Страница 10: ... minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During heating operation When the SLEEP timer is s...

Страница 11: ...remote controller Use the SET buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types of Airflow Direction Setting 1 2 3 During cooling dry modes 1 2 3 4 5 During heating mode The remote cont...

Страница 12: ...eeds To select up down swing operation ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green will go out Normal operation begins About ECONOMY Operation A...

Страница 13: ...us tom code other than custom code A reset the custom code after replacing the batteries If you do not know the air conditioner custom code setting try each of the custom codes until you find the code which operates the air conditioner Use the following steps to select the custom code of the remote controller Note that the air conditioner cannot receive a signal if the air conditioner has not been...

Страница 14: ...ights on when it is time to clean the air filters After turning the power on press the MANUAL AUTO button for 2 seconds or less on the indoor unit CLEANING AND CARE CAUTION When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized ser...

Страница 15: ... tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emit ted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner result ing in condensation and misting During heating operation the outdoor unit s fan may stop and steam may be seen rising from the u...

Страница 16: ...his air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recircu lating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of the heating ...

Страница 17: ...r can be added up to the maximum of 2 remote controllers Either remote controller can control the air conditioner However the timer functions cannot be used at the secondary unit Group Control 1 remote controller can control up to 16 air conditioners All of the air conditioners will be operated with the same settings The wired remote controller option is required to use the following function Duri...

Отзывы: