Table 105
Estimated System Memory Capacity of Each Controller Enclosure (ETERNUS DX900 S5 with
the Compression Function Enabled)
Drive capacity
System memory capacity (with the Compression function enabled)
Up to 112,639GB
768GB
112,640GB or more 1,536GB
To enable the Compression function in the ETERNUS DX900 S5, a system memory capacity of 768GB or
more is required for each CE.
●
Recommended System Memory Capacity
To use the functions described below with the ETERNUS DX200 S5, installing 128GB (64GB per CM) of system
memory in the ETERNUS DX is recommended.
•
Deduplication/Compression function
•
Unified License
■
System Memory Installation Order
●
ETERNUS DX200 S5
Install the same type of system memory for all the slots.
The configuration is the same for Controller 0 (CM#0) and Controller 1 (CM#1).
●
ETERNUS DX500 S5/DX600 S5
Install the same type of system memory for all the slots.
The configuration is the same for Controller 0 (CM#0) and Controller 1 (CM#1).
●
ETERNUS DX900 S5
When multiple controller enclosures are installed, install the same type of system memory using the same
layout for each controller slot.
Extreme Cache
This section describes the installation conditions and installation rules for PCIe Flash Modules (PFMs).
A PFM is a module that is installed to operate the Extreme Cache function.
Note
•
PFMs with different capacities can be installed in a controller enclosure.
•
The PFM capacity of each controller enclosure can be different.
■
Types of PFMs
The following types of options are available for the Extreme Cache.
•
1.6TB (1.6TB
´
1)
•
3.2TB (3.2TB
´
1)
■
Number of Installable PFMs
Up to eight PFMs can be installed in the controller enclosure.
PFMs with different capacity sizes can exist in the same ETERNUS DX.
6. Hardware Configurations
Installation Conditions and Installation Rules
282
Design Guide