The following table provides the function specifications for the Deduplication/Compression.
Table 56
Deduplication/Compression Function Specifications (ETERNUS DX200 S5, ETERNUS DX500 S5/
DX600 S5)
Model
ETERNUS DX200 S5
ETERNUS DX500 S5
ETERNUS DX600 S5
Number of TPPs available for Deduplication/
Compression settings
4
4
8
Maximum logical capacity that can be a
deduplication/compression target
Up to ten times the DATA_CNTNR Volume (*1)
Maximum logical
capacity of the
DATA_CNTNR Volume
(*2)
If the chunk size is 21MB 384TB
1,024TB
1,536TB
If the chunk size is
336MB
6,144TB
16,384TB
24,576TB
Volume type
TPV
¡
(*3)
Standard / FTV / WSV /
SDV / SDPV / VVOL / ODX
´
System memory capacity (per CE)
128GB (recommended)
128GB or more
192GB or more
*1:
If a Deduplication/Compression Volume is created or expanded, expand the DATA_CNTNR Volume according to the total capacity of
the Deduplication/Compression Volumes. If the efficiency of the Deduplication/Compression function cannot be estimated, the
recommended total capacity of Deduplication/Compression Volumes is a capacity smaller than the logical capacity of the
DATA_CNTNR Volume.
*2:
When the Deduplication/Compression function is used, the total capacity of the Deduplication/Compression Volumes can be greater
than or equal to the capacity of the DATA_CNTNR Volume. If deduplication/compression is not effective for this case, a write
operation to a Deduplication/Compression Volume may fail due to a capacity shortage of the DATA_CNTNR Volume. The default
logical capacity of the DATA_CNTNR Volume is 32TB.
In addition, if the DATA_CNTNR Volume capacity runs out or is close to running out, an SNMP Trap is sent.
*3:
NAS user volumes are not supported.
Table 57
Compression Function Specifications (ETERNUS DX900 S5)
Model
ETERNUS DX900 S5
Number of TPPs available for Compression settings
8
Maximum logical capacity that can be a compression target
Up to ten times the DATA_CNTNR Volume (*1)
Maximum logical
capacity of the
DATA_CNTNR Volume
(*2)
If the chunk size is 21MB
8PB
If the chunk size is 336MB
48PB
Volume type
TPV
¡
Standard / FTV / WSV / SDV / SDPV / VVOL / ODX
´
System memory capacity (per CE)
768GB or more
*1:
If a Compression Volume is created or expanded, expand the DATA_CNTNR Volume according to the total capacity of the
Compression Volumes. If the efficiency of the Compression function cannot be estimated, the recommended total capacity of
Compression Volumes is a capacity smaller than the logical capacity of the DATA_CNTNR Volume.
*2:
The Compression function can create Compression Volumes whose capacity is equal to or larger than a DATA_CNTNR Volume. In
environments where compression is not effective, a write operation to the Compression Volume may fail due to a capacity shortage
of the DATA_CNTNR Volume. The default logical capacity of the DATA_CNTNR Volume is 32TB.
In addition, if the DATA_CNTNR Volume capacity runs out or is close to running out, an SNMP Trap is sent.