Notify your supplier immediately if you discover any transport damage or if the
packaging content does not match the delivery note.
4.3
Installing the Server Blade in the Basic Unit
Depending on the configuration, the PRIMERGY BX630 S2 Scalable Server
Blade occupies one or two of the ten slots in the PRIMERGY BX600 S2 or
BX600 S3 basic unit. This section describes how to install the BX630 S2 dual-
socket server blade in the basic unit.The BX630 S2 quad-socket server blade is
installed in the same way.
V
CAUTION!
●
Make sure you observe the safety notes and the information on
handling electrostatic-sensitive devices in the
section “Notes on
safety” on page 17
.
●
Server blade boots automatically after installation in a switched-
on BX600 S3 basic unit with management blade S3.
If you insert a BX630 S2 server blade into a switched-on BX600 S3
basic unit with management blade S3, the server blade will automat-
ically perform a POST (Power-On Self-Test) and then switch itself off.
You may not switch off the server blade during the automatic boot
process!
If the BX600 S3 basic unit is switched off when the server blade is
installed, the POST will be performed automatically after the basic
unit is switched on.
●
PRIMERGY BX630 S2 server blades are not for use in slots 4 an 10
of the PRIMERGY BX600 S2 basic unit.
Removing the Dummy Module
Any unused slots in the BX600 S2 or BX600 S3 basic unit are fitted with appro-
priate dummy modules to comply with the electromagnetic compatibility (EMC)
regulations and ensure sufficient cooling of the system components.
To add a server blade, you must first remove the dummy module from the corre-
sponding slot.