Call the SE Manager, e.g. after logging in on the local console via the browser of the Linux desktop (in the
“Computer” menu in the task bar) or via an administration PC (default), see the “Operation and
Administration” manual [ ].
Redundant MUs are switched on in the same way.
3. Switch on the Server Unit SU /390
>
As the administrator, BS2000 administrator or a privileged operator, switch on the Server Unit using the SE
Manager (menu
,
tab,
symbol), see the “Operation and Administration”
Hardware
->
Units Units
Switch on
Alternatively you can switch the Server Unit on by pressing the POWER ON button on the server's control panel
). The system is ready when the status indicator on the server's control panel
"Control panel (on the SE /390)"
displays no further error codes.
Then you can call an SVP console window in the SE Manager and start the BS2000 system using PROGRAM
LOAD FRAME: DETAIL-1.
When a POWER ON IPL is configured, the BS2000 system is loaded automatically (using AUXILIARY FRAME:
LOAD PRESET1).
Alternatively the IPL can also be initiated in the SE Manager (see the menu
[
Systems
->
<se server> (SE<model>)
]
, “Operation and Administration” manual [ ]).
->
<unit> (SU</390>)
->
BS2000 operation mode
4. Switch on the optional Server Units x86 (SE700/SE500 only)
Before the Server Unit is switched on, the status indicator lights up orange.
>
Switch on the Server Unit by pressing the On/Off switch.
The power-on indicator lights up green. The Server Unit switches on, conducts a system test and starts
X2000.
If automatic IPL is configured for BS2000, the BS2000 system (Native or as a VM2000 monitor system) is
also started with the configured settings.
If automatic startup is configured for XenVMs, these systems are also started.
Further Server Units x86 are switched on in the same way.
The control panel and SVP frames of the Server Unit are described in the "Server Unit /390" Operating
Manual [ ].
i
The controls and indicators of the Server Unit are described in the "Server Unit x86" Operating Manual [ ].
i
Содержание BS2000 SE Series
Страница 5: ...5 Basic Operating Manual ...
Страница 7: ...7 Figure 1 SE Server SE700 and SE700B ...
Страница 8: ...8 Figure 2 SE Server SE710 ...
Страница 29: ...29 Figure 6 System components SE710 basic configuration on the left with optional components on the right ...
Страница 31: ...31 4 Racks The description is divided into the following sections Basic rack Extension rack Power supply ...
Страница 33: ...33 Figure 8 Basic rack SE710 SE310 ...
Страница 35: ...35 Figure 10 SE710 with two extension racks In all an SE server can comprise at most four extension racks ...