TROUBLESHOOTING

Instructions relating to heating (*) are applicable to “HEAT PUMP MODEL” and “HEAT RECOVERY MODEL”.

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

*

During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

*

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

*

When Heating operation is started, indoor unit’s fan may stop, to
allow internal parts to warm up.

*

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit’s fan will stop. If you wish to warm the room further, set the
thermostat for a higher setting.

*

During Heating operation, the unit will temporarily stop opera-
tion (between 2 and 16 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
indicator lamp will flash.

The fan may operate at low speed during Dry operation or when
the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at low speed.

*

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

6

6

6

6

NORMAL

FUNCTION

WARNING!

Содержание AW 7TF

Страница 1: ...ERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES Indoor Unit AW 7TF AW 9TF AW 12TF AW 14TF AW 18TF AW 24TF AW 30TF CEILING WALL TYPE English Deutsch Français Español Italiano EλληvIkά Русский Português TM ...

Страница 2: ... conditioner or the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter do Turn the power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditione...

Страница 3: ... 4 Fig 3 Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button 3 Remote Control Signal Receiver 4 Indicator Lamps Fig 3 5 OPERATION Indicator Lamp green COOL DRY FAN red HEAT 6 TIMER Indicator Lamp yellow 7 SWING Indicator Lamp orange VERTICAL SWING 8 SWING Indicator Lamp orange HORIZONTAL SWING Fig 2 Instructions relating to heating are applicable to HEAT PUMP MODEL and HEAT RECO...

Страница 4: ...on once again When the air conditioner is operated with the controls on the Main unit it will operate under the same mode as the AUTO mode selected on the re mote control unit However the Heat pump model will follow the operating mode of the other indoor unit The fan speed selected will be AUTO and the thermostat setting will be 23 C Do not press the MANUAL AUTO button with wet hands or pointed ob...

Страница 5: ...llowed to accumulate on the intake filters air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use the intake filters should be cleaned every five weeks 3 Install the intake filters Hang the edge of the intake filter on the body Using this as a support point push forward to secure as shown in the illustration When using the optional Air Cleaning Fil...

Страница 6: ...front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the ind...

Страница 7: ... throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Cooling Heating Priority HEAT PUMP MODEL only If another indoor unit in the same refrigerant system is already operating in the cooling mode or dry mode heat ing mode settings cannot be performed Operation in the cooling or dry mode will continue If another indoor ...

Страница 8: ... this unit for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings SPECIFICATIONS Temperature and Humidity Range MODEL POWER COOLING CAPACITY kW HEATING CAPACITY kW DIMENSIONS WEIGHT HEIGHT mm WIDTH mm DEPTH mm WEIGHT kg Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for both indoor unit and outdoor unit Acc...