TROUBLESHOOTING

Instructions relating to heating (*) are applicable to “HEAT PUMP MODEL” and “HEAT RECOVERY MODEL”.

Symptom

Doesn’t operate at all:

Poor Cooling
(or *Heating)
performance:

See Page

CHECK ONCE

MORE

Items to check

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the main power switch set to the OFF position?

Is the timer operating?

Is the air filter dirty?

Are the air conditioner’s intake grille or outlet port blocked?

Did you adjust the room temperature settings (thermostat) cor-
rectly?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)

In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?

If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off the
electrical breaker, and consult with authorized service personnel.

OPERATING TIPS

*Heating Performance

This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.

Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.

Cooling/Heating Priority (HEAT PUMP MODEL only)

If another indoor unit in the same refrigerant system is
already operating in the cooling mode or dry mode, heat-
ing mode settings cannot be performed. (Operation in
the cooling or dry mode will continue.)

If another indoor unit in the same refrigerant system is
already operating in the heating mode, cooling mode or
dry mode settings cannot be performed. (Operation in
the heating mode will continue.)

Operation and Performance

*Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low out-
door air temperature high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.

In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Automatic
Defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate
briefly (for about 2 to 16 minutes).

During Automatic Defrosting operation, the OPERATION in-
dicator lamp (red) will flash.

Oil Recovery Operation

Periodically, the oil recovery operation is performed in or-
der to return compressor oil to the outdoor unit.  Operation
is stopped during this oil recovery operation.  During oil re-
covery operation, the OPERATION indicator lamp will flash.

Low Ambient Cooling

When the outdoor temperature drops, the outdoor unit’s fans
may switch to Low Speed, or one of the fans may stop inter-
mittently.

Instructions relating to heating (*) are applicable to “HEAT PUMP MODEL” and “HEAT RECOVERY MODEL”.

Содержание AW 7TF

Страница 1: ...ERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES Indoor Unit AW 7TF AW 9TF AW 12TF AW 14TF AW 18TF AW 24TF AW 30TF CEILING WALL TYPE English Deutsch Français Español Italiano EλληvIkά Русский Português TM ...

Страница 2: ... conditioner or the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter do Turn the power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditione...

Страница 3: ... 4 Fig 3 Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button 3 Remote Control Signal Receiver 4 Indicator Lamps Fig 3 5 OPERATION Indicator Lamp green COOL DRY FAN red HEAT 6 TIMER Indicator Lamp yellow 7 SWING Indicator Lamp orange VERTICAL SWING 8 SWING Indicator Lamp orange HORIZONTAL SWING Fig 2 Instructions relating to heating are applicable to HEAT PUMP MODEL and HEAT RECO...

Страница 4: ...on once again When the air conditioner is operated with the controls on the Main unit it will operate under the same mode as the AUTO mode selected on the re mote control unit However the Heat pump model will follow the operating mode of the other indoor unit The fan speed selected will be AUTO and the thermostat setting will be 23 C Do not press the MANUAL AUTO button with wet hands or pointed ob...

Страница 5: ...llowed to accumulate on the intake filters air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use the intake filters should be cleaned every five weeks 3 Install the intake filters Hang the edge of the intake filter on the body Using this as a support point push forward to secure as shown in the illustration When using the optional Air Cleaning Fil...

Страница 6: ...front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the ind...

Страница 7: ... throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Cooling Heating Priority HEAT PUMP MODEL only If another indoor unit in the same refrigerant system is already operating in the cooling mode or dry mode heat ing mode settings cannot be performed Operation in the cooling or dry mode will continue If another indoor ...

Страница 8: ... this unit for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings SPECIFICATIONS Temperature and Humidity Range MODEL POWER COOLING CAPACITY kW HEATING CAPACITY kW DIMENSIONS WEIGHT HEIGHT mm WIDTH mm DEPTH mm WEIGHT kg Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for both indoor unit and outdoor unit Acc...

Отзывы: