ADJUSTING THE DIRECTION OF AIR CIRCULATION

SWING OPERATION

Begin air conditioner operation before performing this procedure.

To select SWING Operation

Press the SWING button

The SWING indicator will light.
In this mode, the air

fl

 ow direction louvers will swing automatically to direct the air 

fl

 ow 

both up and down.

To stop SWING Operation

Press the SWING button once again.

The SWING indicator will go out.
Air

fl

 ow direction will return to the setting before swing was begun.

  Attempting to move up/down air direc-

tion flaps manually could result in im-
proper operation; in this case, stop op-
eration and restart. The louvers should 
begin to operate properly again.

  When used in a room with infants, chil-

dren, elderly or sick persons, the air 
direction and room temperature should 
be considered carefully when making 
settings.

Vertical Air Direction Adjustment

Press the SET button (Vertical).

Each time the button is pressed, the air direction range will change as follows:

1

 

 

2

 

 

3

 

 

4

The remote controller’s display 
does not change.

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Begin air conditioner operation before performing this procedure.

Air

fl

 ow direction setting:

1

2

3

4

: During cooling/heating/dry mode

  The vertical air

fl

 ow direction is set automatically as shown, in accordance with the 

type of operation selected.
  During cooling/dry mode 

:  Horizontal 

fl

 ow 

1

  During heating mode * 

:  Downward 

fl

 ow 

4

  During AUTO mode operation, for the 

fi

 rst minute after beginning operation, air

fl

 ow 

will be horizontal 

1

; the air direction cannot be adjusted during this period.

Horizontal Air Direction Adjustment

The function cannot be used.

About SWING Operation

The type of operation

Range of swing

Cooling/Heating/Dry/Fan

1

 to 

4

The SWING operation may stop temporarily when the air conditioner’s 
fan is not operating, or when operating at very low speeds

OM 01_9374379712-02 EN.indd   11

OM 01_9374379712-02 EN.indd   11

1/22/2559 BE   21:37

1/22/2559 BE   21:37

Содержание AUY35UIA-LV

Страница 1: ... REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA ХРАНИТЕ РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU İLERİDE BAŞVURMAK ÜZERE SAKLAYIN PART No 93...

Страница 2: ...ing children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not start or stop the operation of this product by inserting or pulling out the power ...

Страница 3: ...it will flash The restricted functions for wireless ones SLEEP timer TIMER 10 C HEAT operation Energy saving and Comfortable function INVERTER At the start of operation large amount of power is used to bring the room quickly to the desired temperature Afterwards the unit automatically switches to a low power setting for eco nomic and comfortable operation ECONOMY OPERATION When ECONOMY operation m...

Страница 4: ...sonnel s use When the forced cooling operation starts by any chance press the START STOP button to stop the operation Please press the button at Filter Reset 7 OPERATION indicator lamp green 8 TIMER indicator lamp orange TIMER indicator lamp lights when the timer is set from wireless remote control 9 ECONOMY indicator lamp green ECONOMY indicator lamp lights in following operations ECONOMY operati...

Страница 5: ...y To stop the test operation mode press the START STOP button to stop the air condi tioner Signal transmitter Temperature SET indicator Operating mode indicator SLEEP indicator Transmit indicator Fan speed indicator SWING indicator Timer mode indicator Clock indicator Some indoor units may not be equipped with the functions corresponding to all of the buttons on this remote control ler The indoor ...

Страница 6: ...ove the Remote con troller when use at hand Slide up Pull out PREPARATION WARNING Take care to prevent infants and young children from accidentally swallowing the batteries CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended...

Страница 7: ...anges in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the fan speed becomes slow...

Страница 8: ... the indoor unit detects the room conditions and selects the proper mode Room temperature is higher than the defined temperature in temperature setting Cooling mode or dry mode Room temperature is close to or lower than the defined temperature in temperature setting Monitor operation When the indoor unit has adjusted your room s temperature to near the temperature setting it will begin monitor ope...

Страница 9: ... will be the 1 set nearest to the current time The order of operation is indicated by the arrow in the Remote Controller s Display OFF ON or OFF ON An example of program timer use might be to have the air conditioner automatically stop OFF timer after you go to sleep then start ON timer automatically in the morning before you arise TIMER OPERATION To Cancel the Timer Use the TIMER button to select...

Страница 10: ...tting is automati cally raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is main tained until the set time has elapsed at which time the air condi tioner automatically turns off SLEEP timer setting Set time 1 hour 1 C 2 C During heating operation When the SLEEP timer is set the thermostat setting is automatically lowered 1 C every 30 mi...

Страница 11: ...al Each time the button is pressed the air direction range will change as follows 1 2 3 4 The remote controller s display does not change Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Begin air conditioner operation before performing this procedure Airflow direction setting 1 2 3 4 During cooling heating dry mode The vertical airflow direction is set automat...

Страница 12: ... conditioner the ECONOMY operation mode is only available for the set indoor unit 10 C HEAT OPERATION To use 10 C HEAT Operation Press the 10 C HEAT button The OPERATION indicator lamp green will go out and the ECONOMY indicator lamp green will light To stop 10 C HEAT Operation Press the START STOP button Then the operation stops and the ECONOMY indicator lamp green will go out About the 10 C HEAT...

Страница 13: ...code A when the batteries in the Remote Controller are replaced If you use a custom code other than custom code A reset the custom code after replacing the batteries If you do not know the air conditioner custom code setting try each of the custom codes until you find the code which operates the air conditioner Use the following steps to select the custom code of the remote controller Note that th...

Страница 14: ...4 Re attach the air filters to the intake grille 1 Replace the air filter into its holder 2 Make sure that the air filter makes contact with the filter stopper when it is replaced into its holder Intake Grille Air Filter Filter Hook 5 Close the intake grille and push the in take grille s hooks outward Grille Hook Dust can be cleaned from the air filter either with a vacuum cleaner or by washing th...

Страница 15: ...on circuit will operate for about 3 minutes prevent ing unit operation during that period Noise is heard During operation and immediately after stopping the unit the sound of water flowing in the air conditioner s piping may be heard Also noise may be par ticularly noticeable for about 2 to 3 minutes after starting operation sound of coolant flowing During operation a slight squeaking sound may be...

Страница 16: ...it due to the automatic defrosting operation 17 The ECONOMY indi cator lamp flashing Clean the filter Afterwards turn the ECONOMY lamp off 15 CHECK ONCE MORE Does not operate at all Has the circuit breaker been turned off Has there been a power failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating 9 to 10 Poor Cooling or Heating performance Is the air filter dirty A...

Страница 17: ...t will automatically stop after operating for a few minutes However some type of multi type air conditioner doesn t provide this function Low Ambient Cooling When the outdoor temperature drops the outdoor unit s fans may switch to low speed or one of the fans may stop intermit tently This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat...

Страница 18: ...be used in conjunction with other auxiliary space heaters as required Seasonal and outdoor temperature conditions the struc ture of the rooms and the number of persons present may also result in differences of operating efficiency We rec ommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in the way tha...

Отзывы: