Fujitsu AUT12 Скачать руководство пользователя страница 8

7

OPERATION

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

* During Heating mode:

Set the thermostat to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling and Dry modes
will not operate if the thermostat is set
higher than the actual room temperature
(in Cooling mode, the fan alone will oper-
ate).

During Fan mode:

The heat and cool functions of this unit
cannot operate at the same time.

About Mode Operation

AUTO:
COOLING MODEL

When the room temperature is 2 °C
higher than the set temperature, the
mode will switch between Cooling and
Drying.

During the Drying mode operation, the
FAN setting should be switched to LOW
for a gently cooling effect during which
the fan may temporarily stop rotating.

If the mode automatically selected by the
unit is not satisfactory, see page 6 for in-
structions on changing the mode setting
(COOL, DRY, FAN).

AUTO (* AUTO CHANGEOVER):
HEAT & COOL MODEL (Reverse cycle)

When AUTO CHANGEOVER is selected, the air conditioner selects the appropri-
ate operation mode (Cooling or Heating) according to your room’s present tem-
perature.

When AUTO CHANGEOVER is first selected, the fan will operate at very low speed
for about one minute while the unit determines the current conditions of the
room and accordingly selects the proper operation mode.

When the air conditioner has adjusted your room’s temperature to near the ther-
mostat setting, it will begin monitor operation. In the monitor operation mode,
the fan will operate at low speed. If the room temperature subsequently changes,
the air conditioner will once again select the appropriate operation (Heating, Cool-
ing) to adjust the temperature to the value set in the thermostat. (The monitor
operation range is ±2 °C relative to the thermostat setting.)

If the mode automatically selected by the unit is not satisfactory, see page 6 for
instructions on changing the mode setting (HEAT, COOL, DRY, FAN).

*Heating:

Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very low fan
speed for about 3 to 5 minutes, after which it will switch to the selected fan set-
ting. This period of time is provided to allow the indoor unit to warm up before
beginning full operation.

When the room temperature is very low, frost may form on the outside unit, and
its performance may be reduced. In order to remove such frost, the unit will
automatically enter the defrost cycle from time to time. During Automatic De-
frosting operation, the OPERATION indicator lamp (red) will flash, and the heat
operation will be interrupted.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room
humidity, the indoor unit’s fan may stop from time to time. Also, the fan may
operate at very low speed when detecting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan:

Use to circulate the air throughout your room.

Setting temperature

Thermostat control

Dry Operation

Cooling Operation

2 °C

Содержание AUT12

Страница 1: ...AIR CONDITIONER CASSETTE TYPE KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED Indoor Unit AUT12 AUT14 AUT18 Outdoor Unit AOT12 AOT14 AOT18 P N9361112049 OPERATING MANUAL ...

Страница 2: ...for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or chang ing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involvi...

Страница 3: ...ion during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easie...

Страница 4: ...licable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 6 Fig 7 Fig 1 This breaker is installed during the electrical installation Fig 3 Fig 4 Electrical Breaker Fig 2 0 A 0 0 A SWING TIMER OPERATION MANUAL AUTO 2 3 4 9 5 6 7 8 1 ...

Страница 5: ...ultaneously To stop the test operation mode press the START STOP button to stop the air condi tioner N Remote Control Unit Display Fig 7 O Transmit Indicator P Clock Display Q Operating Mode Display R Timer Mode Display S Fan Speed Display T Temperature Set Display U Timer Set Indicator V Temperature Set Indicator Fig 1 Indoor Unit 1 Air Filter 2 Horizontal Louvers 3 Indicator Lamps Fig 2 4 SWING ...

Страница 6: ...de to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the ...

Страница 7: ...t three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heatin...

Страница 8: ...ir conditioner has adjusted your room s temperature to near the ther mostat setting it will begin monitor operation In the monitor operation mode the fan will operate at low speed If the room temperature subsequently changes the air conditioner will once again select the appropriate operation Heating Cool ing to adjust the temperature to the value set in the thermostat The monitor operation range ...

Страница 9: ...on in this case stop operation and restart The louvers should begin to operate properly again When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings SWING OPERATION Begin air conditioner operation before performing this procedure To Select SWING Operation Press the AIR FLOW DIRECTION SWING button...

Страница 10: ... s s t To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Change the Timer Settings Perform steps 2 and 3 To Stop Air Conditioner Operation while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer s...

Страница 11: ...e section To Use the ON timer or OFF timer to set the desired mode and times About five seconds later the entire display will reappear The indoor unit s TIMER indicator lamp green will light 3 Press the TIMER button to select the PROGRAM timer operation either OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operati...

Страница 12: ...n During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered 1 C every thirty minutes When the thermostat has been lowered a total of 4 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Cooling Dry operation When the SLEEP timer is set the ...

Страница 13: ...er or by washing the filter in a solution of mild de tergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increas ing noise During periods of normal use the air filters should be cleaned every two weeks Grille Hook Air Fi...

Страница 14: ...st five seconds to display the current signal code initially set to 3 Press the buttons Fig 5 D to change the signal code between Match the code on the dis play to the air conditioner signal code 4 Press the MASTER CONTROL button again to return to the clock display The signal code will be changed SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE To operate only one of multiple air conditioners If no ...

Страница 15: ...ure changes During Heating operation a sizzling sound may be heard occa sionally This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results fro...

Страница 16: ...ns relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Operation and Performance Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we ...

Страница 17: ...tdoor temperature Indoor temperature Indoor humidity COOLING MODEL HEAT COOL MODEL Reverse Cycle If the air conditioner is operated under higher temperature conditions than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperatures than those listed above the heat exchanger...

Страница 18: ... ...

Страница 19: ......

Страница 20: ......

Отзывы: