TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the power switch is turned off then on again, the pro-
tection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

*

During Heating operation, a sizzling sound may be heard occa-
sionally. This sound is produced by the Automatic Defrosting op-
eration.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

*

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to the Auto-
matic Defrosting operation.

*

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

*

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat to a higher setting.

*

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During the Automatic Defrosting operation, the OPERA-
TION indicator lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

*

During Heating operation, water may be produced from the out-
door unit due to the Automatic Defrosting operation.

See Page

15

15

15

6

6

15

NORMAL

FUNCTION

Содержание AUT12

Страница 1: ...AIR CONDITIONER CASSETTE TYPE KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED Indoor Unit AUT12 AUT14 AUT18 Outdoor Unit AOT12 AOT14 AOT18 P N9361112049 OPERATING MANUAL ...

Страница 2: ...for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or chang ing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involvi...

Страница 3: ...ion during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easie...

Страница 4: ...licable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 6 Fig 7 Fig 1 This breaker is installed during the electrical installation Fig 3 Fig 4 Electrical Breaker Fig 2 0 A 0 0 A SWING TIMER OPERATION MANUAL AUTO 2 3 4 9 5 6 7 8 1 ...

Страница 5: ...ultaneously To stop the test operation mode press the START STOP button to stop the air condi tioner N Remote Control Unit Display Fig 7 O Transmit Indicator P Clock Display Q Operating Mode Display R Timer Mode Display S Fan Speed Display T Temperature Set Display U Timer Set Indicator V Temperature Set Indicator Fig 1 Indoor Unit 1 Air Filter 2 Horizontal Louvers 3 Indicator Lamps Fig 2 4 SWING ...

Страница 6: ...de to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the ...

Страница 7: ...t three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heatin...

Страница 8: ...ir conditioner has adjusted your room s temperature to near the ther mostat setting it will begin monitor operation In the monitor operation mode the fan will operate at low speed If the room temperature subsequently changes the air conditioner will once again select the appropriate operation Heating Cool ing to adjust the temperature to the value set in the thermostat The monitor operation range ...

Страница 9: ...on in this case stop operation and restart The louvers should begin to operate properly again When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings SWING OPERATION Begin air conditioner operation before performing this procedure To Select SWING Operation Press the AIR FLOW DIRECTION SWING button...

Страница 10: ... s s t To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Change the Timer Settings Perform steps 2 and 3 To Stop Air Conditioner Operation while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer s...

Страница 11: ...e section To Use the ON timer or OFF timer to set the desired mode and times About five seconds later the entire display will reappear The indoor unit s TIMER indicator lamp green will light 3 Press the TIMER button to select the PROGRAM timer operation either OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operati...

Страница 12: ...n During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered 1 C every thirty minutes When the thermostat has been lowered a total of 4 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Cooling Dry operation When the SLEEP timer is set the ...

Страница 13: ...er or by washing the filter in a solution of mild de tergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increas ing noise During periods of normal use the air filters should be cleaned every two weeks Grille Hook Air Fi...

Страница 14: ...st five seconds to display the current signal code initially set to 3 Press the buttons Fig 5 D to change the signal code between Match the code on the dis play to the air conditioner signal code 4 Press the MASTER CONTROL button again to return to the clock display The signal code will be changed SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE To operate only one of multiple air conditioners If no ...

Страница 15: ...ure changes During Heating operation a sizzling sound may be heard occa sionally This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results fro...

Страница 16: ...ns relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Operation and Performance Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we ...

Страница 17: ...tdoor temperature Indoor temperature Indoor humidity COOLING MODEL HEAT COOL MODEL Reverse Cycle If the air conditioner is operated under higher temperature conditions than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperatures than those listed above the heat exchanger...

Страница 18: ... ...

Страница 19: ......

Страница 20: ......

Отзывы: