background image

En-17

TROUBLESHOOTING

Symptom

Diagnostic

See Page

CHECK ONCE

MORE

Doesn’t operate at all:

  Has the circuit breaker been turn off?

  Has there been a power failure?

  Has a fuse blown out, or a circuit breaker been tripped?

  Is the timer operating?

8 - 9

Poor Cooling (or Heating) 

performance:

  Is the Air Filter dirty?

  Are the air conditioner’s intake grille or outlet port blocked?

 Did you adjust the room temperature settings (thermostat) 

correctly?

  Is there a window or door open?

  In the case of Cooling operation, is a window allowing bright 

sunlight to enter? (Close the curtains.)

  In the case of Cooling operation, are there heating apparatus 

and computers inside the room, or are there too many people 

in the room?

  Is the unit set for SUPER QUIET operation?

6

The unit operates 

differently from the Remote 

Controller’s setting:

  Are the Remote Controller’s batteries dead?

  Are the Remote Controller’s batteries loaded properly?

5

OPERATING TIPS

If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp (Fig. 3 

5

and the TIMER Indicator Lamp (Fig. 3 

6

fl

 ashes and ECONOMY Indicator Lamp (Fig.3 

7

fl

 ashes fast, immediately stop operation, 

turn off the electrical breaker and consult authorized service personnel.

Operation and Performance

Heating Performance

 This air conditioner operates on the heat-pump principle, 

absorbing heat from outdoor air and transferring that heat 
to indoor unit. As a result, the operating performance is 
reduced as outdoor air temperature drops. If you feel that 
insufficient heating performance is being produced, we 
recommend you use this air conditioner in conjunction with 
another kind of heating appliance.

 Heat-pump air conditioners heat your entire room by recir-

culating air throughout the room, with the result that some 
time may be required after 

fi

 rst starting the air conditioner 

until the room is heated.

Microcomputer-controlled Automatic Defrosting

  When using the Heating mode under conditions of low out-

door temperature and high humidity, frost may form on the 
outdoor unit, resulting in reduced operating performance.

  In order to prevent this kind of reduced performance, this 

air conditioner is equipped with a Microcomputer-controlled 
Automatic Defrosting function. If frost forms, the air con-
ditioner will temporarily stop, and the defrosting circuit will 
operate brie

fl

 y (Max. 15 minutes).

  During Automatic Defrosting operation, the OPERATION 

Indicator Lamp (green) will 

fl

 ash.

 After heating operation stops, if frost forms on the outdoor 

unit, the unit will start Automatic Defrosting operation. At 
this time, the outdoor unit will automatically stop after oper-
ating for a few minutes.

9315345516_OM.indb   17

9315345516_OM.indb   17

9/27/2012   1:52:25 PM

9/27/2012   1:52:25 PM

Содержание ASY71UI-LF

Страница 1: ... й и к с с у Р KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR СОХРАНИТЕ НАСТОЯЩЕЕ Р...

Страница 2: ...Turn off power supply when not using the indoor unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the airflow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Connection valves become hot during Hea...

Страница 3: ... the SLEEP timer button is pressed during heating mode the air conditioner s thermostat setting is gradually lowered dur ing the period of operation during cooling or dry mode the ther mostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off Clean function REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed f...

Страница 4: ...as been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 1 Fig 2 Fig 3 Fig 4 NAME OF PARTS 9315345516_OM indb 3 9315345516_OM indb 3 9 27 2012 1 52 18 PM 9 27 2012 1 52 18 PM ...

Страница 5: ...play SWING Display Timer Mode Display Clock Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling operation starts by any chance press ...

Страница 6: ...atteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 S Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 R to adjust the clock to the current time button Press to advance the time button Press to reverse the time Each time the buttons are pr...

Страница 7: ...s pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting ...

Страница 8: ...l ing mode the fan alone will operate During Fan mode You can not use the unit to heat and cool your room Indoor unit fan control for energy sav ing With stopping rotation of the indoor unit fan when the outdoor unit is stopped it ena bles power saving operation In initial setting this function is activated To inactivate the function consult the in staller or authorized service personnel Even if t...

Страница 9: ...he ON timer or OFF timer to set the desired mode and times About 3 seconds later the entire display will reappear The indoor unit s TIMER Indicator Lamp orange Fig 3 6 will light 3 Press the TIMER MODE button Fig 5 K to select the PROGRAM timer operation OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation to ...

Страница 10: ...ut the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in ac cordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automati cally raised 1 C every 1 hour When the thermostat has bee...

Страница 11: ...ustment Press the SET button Vertical Fig 5 N Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Airflow Direction Setting 1 2 3 4 5 6 During Heating Cooling Dry modes The Remote Controller s display does not change Use the air direction adjustments within the ranges shown above The vertical airflow direction is set automatically as shown in accorda...

Страница 12: ...de is able to save more energy than other normal mode In case of multi type air conditioner the ECONOMY operation mode is only available for the set indoor unit Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using t...

Страница 13: ...g the 10 C HEAT function we recommend all indoor units should be run under the 10 C HEAT mode While 10 C HEAT OPERATION is in progress only the following operation can be used SWING How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 more than 3 seconds and less than 10 seconds on the main unit control panel To stop operation press the MANUAL AUTO button Fig 2 2 once again Contr...

Страница 14: ... Filter and close the Intake Grille 1 Align the sides of the air filter with the panel and push in fully making sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit with out Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a s...

Страница 15: ...and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters Negative air ions...

Страница 16: ...ditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the Remote Controller display 2 Press the MODE button for at least five seconds to display the current signal code initially set to 3 Press the buttons to change the signal code between Match the code on the display to the air conditio...

Страница 17: ...t This results from the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation 17 Airflow is weak or stops When Heating operation is started fan speed is temporarily very low to allow internal parts ...

Страница 18: ... Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat to indoor unit As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance He...

Страница 19: ...r auxiliary space heaters as required Seasonal and outdoor temperature conditions the struc ture of the rooms and the number of persons present may also result in differences of operating efficiency We rec ommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in the way that best matches your family s lif...

Отзывы: