TROUBLESHOOTING

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical 
breaker and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power 
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING

Symptom

Cause

See Page

NORMAL

FUNCTION

Doesn’t operate immedi-

ately:

 If the indoor unit is stopped and then immediately started 

again, the compressor will not operate for about 3 minutes, in 

order to prevent fuse blowouts.

 Whenever the electrical breaker is turned off then on again 

the protection circuit will operate for about 3 minutes, pre-

venting unit operation during that period.

Noise is heard:

 During operation or immediately after stopping the unit, the 

sound of water 

fl

 owing in the air conditioner’s piping may be 

heard. Also, noise may be particularly noticeable for about 

2 to 3 minutes after starting operation (sound of refrigerant 

fl

 owing).

 During operation, a slight squeaking sound may be heard. 

This is the result of minute expansion and contraction of the 

front panel due to temperature changes.

  During Heating operation, a sizzling sound may be heard oc-

casional. This sound is produced by the Automatic Defrosting 

operation.

17

Smells:

 Some smell may be emitted from the indoor unit. This smell 

is the result of room smells (furniture, tobacco, etc.) which 

have been taken into the indoor unit.

Mist or steam is 

emitted:

 During Cooling or Dry operation, a thin mist may be seen 

emitted from the indoor unit. This results from the sudden 

Cooling of room air by the cool air emitted from the indoor 

unit, resulting in condensation and misting.

 During Heating operation, the outdoor unit’s fan may stop, 

and steam may be seen rising from the unit. This is due to 

Automatic Defrosting operation.

17

Air

fl

 ow is weak or stops:

 When Heating operation is started, fan speed is temporarily 

very low, to allow internal parts to warm up.

 During Heating operation, if the room temperature rises 

above the thermostat setting, the outdoor unit will stop, and 

the indoor unit will operate at very low fan speed. If you wish 

to warm the room further, set the thermostat for a higher set-

ting.

 During Heating operation, the indoor unit will temporarily 

stop operation (Max. 15 minutes) as the Automatic Defrosting 

mode operates. During Automatic Defrosting operation, the 

OPERATION Indicator Lamp will 

fl

 ash.

17

 During Dry mode, the indoor unit will operate at low speed; 

in order to adjust room humidity, the indoor unit’s fan may 

stop from time to time. Also, the fan may operate at very low 

speed when adjusting room humidity.

7

  During SUPER QUIET operation, the fan will operate at very 

low speed.

6

 When the outdoor unit is stopped, the indoor unit's fan may 

stop from time to time in cooling operation.

7

  In the monitor of AUTO operation, the fan will operate at very 

low speed.

7

  In case of Multi-type unit, if multiple units are operated in 

different operation modes as shown below, the units oper-

ated afterward will stop and the OPERATION indicator lamp 

(green) will 

fl

 ash.

Heating mode and cooling mode (or dry mode)

Heating mode and fan mode

18

Water is produced from the 

outdoor unit:

● 

During Heating operation, water may be produced from the 
outdoor unit due to Automatic Defrosting operation.

17

9315345516_OM.indb   16

9315345516_OM.indb   16

9/27/2012   1:52:25 PM

9/27/2012   1:52:25 PM

Содержание ASY71UI-LF

Страница 1: ... й и к с с у Р KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR СОХРАНИТЕ НАСТОЯЩЕЕ Р...

Страница 2: ...Turn off power supply when not using the indoor unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the airflow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Connection valves become hot during Hea...

Страница 3: ... the SLEEP timer button is pressed during heating mode the air conditioner s thermostat setting is gradually lowered dur ing the period of operation during cooling or dry mode the ther mostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off Clean function REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed f...

Страница 4: ...as been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 1 Fig 2 Fig 3 Fig 4 NAME OF PARTS 9315345516_OM indb 3 9315345516_OM indb 3 9 27 2012 1 52 18 PM 9 27 2012 1 52 18 PM ...

Страница 5: ...play SWING Display Timer Mode Display Clock Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling operation starts by any chance press ...

Страница 6: ...atteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 S Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 R to adjust the clock to the current time button Press to advance the time button Press to reverse the time Each time the buttons are pr...

Страница 7: ...s pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting ...

Страница 8: ...l ing mode the fan alone will operate During Fan mode You can not use the unit to heat and cool your room Indoor unit fan control for energy sav ing With stopping rotation of the indoor unit fan when the outdoor unit is stopped it ena bles power saving operation In initial setting this function is activated To inactivate the function consult the in staller or authorized service personnel Even if t...

Страница 9: ...he ON timer or OFF timer to set the desired mode and times About 3 seconds later the entire display will reappear The indoor unit s TIMER Indicator Lamp orange Fig 3 6 will light 3 Press the TIMER MODE button Fig 5 K to select the PROGRAM timer operation OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation to ...

Страница 10: ...ut the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in ac cordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automati cally raised 1 C every 1 hour When the thermostat has bee...

Страница 11: ...ustment Press the SET button Vertical Fig 5 N Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Airflow Direction Setting 1 2 3 4 5 6 During Heating Cooling Dry modes The Remote Controller s display does not change Use the air direction adjustments within the ranges shown above The vertical airflow direction is set automatically as shown in accorda...

Страница 12: ...de is able to save more energy than other normal mode In case of multi type air conditioner the ECONOMY operation mode is only available for the set indoor unit Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using t...

Страница 13: ...g the 10 C HEAT function we recommend all indoor units should be run under the 10 C HEAT mode While 10 C HEAT OPERATION is in progress only the following operation can be used SWING How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 more than 3 seconds and less than 10 seconds on the main unit control panel To stop operation press the MANUAL AUTO button Fig 2 2 once again Contr...

Страница 14: ... Filter and close the Intake Grille 1 Align the sides of the air filter with the panel and push in fully making sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit with out Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a s...

Страница 15: ...and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters Negative air ions...

Страница 16: ...ditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the Remote Controller display 2 Press the MODE button for at least five seconds to display the current signal code initially set to 3 Press the buttons to change the signal code between Match the code on the display to the air conditio...

Страница 17: ...t This results from the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation 17 Airflow is weak or stops When Heating operation is started fan speed is temporarily very low to allow internal parts ...

Страница 18: ... Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat to indoor unit As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance He...

Страница 19: ...r auxiliary space heaters as required Seasonal and outdoor temperature conditions the struc ture of the rooms and the number of persons present may also result in differences of operating efficiency We rec ommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in the way that best matches your family s lif...

Отзывы: