Fujitsu ASUH36LPAS Скачать руководство пользователя страница 8

En-8

 CAUTION

•  Attach the cable clamp firmly by holding the connection cable, and make sure that the 

clamp is fixed securely. 

Incomplete attachment of the cable clamp might cause a malfunction of the open 

panel.

•  Match the terminal block numbers and connection cable colors with those of the 

outdoor unit or branch box.

Erroneous wiring may cause burning of the electric parts.

•  Connect the connection cables firmly to the terminal block. Imperfect installation may 

cause a fire.

•  Always fasten the outside covering of the connection cable with the cable clamp. 

(If the insulator is chafed, electric discharge may occur.)

•  Always connect the ground (earth) wire.

•  Do not use the ground (earth) screw of the indoor unit for the connection other than a 

specified outdoor unit.

(7)  Fix the conduit with the supporters as shown below.

Conduit (Power supply cable)

Indoor unit

Supporter

30 in  

(756 mm)  

or less

54 in 

(1,360 mm)  

or less

54 in 

(1,360 mm)  

or less

54 in 

(1,360 mm)  

or less

3.5. Remote controller installation

• Check that the indoor unit correctly receives the signal from the remote controller, then 

install the remote controller holder.

 CAUTION

Do not install the remote controller holder in the following conditions:

•  Any places exposed in direct sunlight

•  Positions affected by the heat from a stove or heater

3.5.1. Remote controller holder installation

  Install the remote controller a maximum distance of 22 ft (7 m) m from the remote con-

trol signal receiver. After installing the remote controller, check that it operates correctly.

 Install the remote controller holder to a wall, pillar, etc. with the tapping screw.

(1) Set

Remote controller 

holder fixing

Remote 

controller holder

Tapping screws  

(small, acces-

sories)

Remote controller 

mounting

Remote 

controller

(2) Down

3.5.2. Remote controller custom setting

 Custom code setting

By setting custom code of indoor unit and remote controller, you can specify the air condi-
tioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to operate them sepa-
rately, set the custom code (4 selections possible).

NOTE:  

If custom codes is different between the indoor unit and the remote controller, 
the indoor unit cannot receive a signal from the remote controller.

How to set the remote controller custom code

(1)   Press 

 until the indicators on the remote controller turn off.

(2)    Press down [MODE] for more than 5 seconds.
 

The current custom code will be displayed (initially set to  ).

(3)   Press [TEMP./SELECT (

)] to change the custom code between  

A (

) ↔ B ( ) ↔ C (

/

) ↔ D (

).

*  Match the custom code on the display to the air 

conditioner custom code.

(4)   Press [MODE] again.
 

The custom code will be set.  

 

 The display will return to the original display.

• To change the air conditioner custom code, contact an authorized service 

personnel (initially set to  ).

• If you do not press any buttons for 30 seconds after the custom code is displayed, 

the display returns to the original display. In this case, repeat the setting from step 2.

• Depending on the remote controller, the custom code may return to   when 

replacing the batteries. In this case, reset the custom code as necessary. If you 

do not know the air conditioner custom code, try each code until you find the code 

which operates the air conditioner.

4.  OPTIONAL INSTALLATION WORK

 CAUTION

•  Before installing, be sure to disconnect all power supply.

•  Do not touch the heat exchanger.

•  When installing or removing parts of the air conditioner, be sure that the wire is not 

caught by any parts or pulled hard. It may result in damage or malfunction of the air 

conditioner.

•  Connect the cable the circuit board.

CN13

CN65

CN46

CN47

This air conditioner can be connected with the following optional kits. To install these op-

tional kits, the optional External input and output PCB box is necessary.

For details on how to install optional parts, refer to the installation manual included in 

each item.

Connector No.

Option type

CN13

Wired remote controller (via the Communication kit)
Simple remote controller (via the Communication kit)

CN46

External input

CN47

External output

CN65

External input and output PCB

4.1. Optional kit installation

NOTE: 

  When some wired remote controller is connected, the wireless remote controller cannot 

be used.

4.1.1. Installing the WLAN adapter 

    For installing the WLAN adapter, refer to the operation manual.

WLAN adapter cover

WLAN adapter

1. Open

2. Insert

4.1.2.  External input and output 

 

External input

•  Indoor unit functions such as Operation/Stop or Forced stop can be done by using 

indoor unit terminals.

•  “Operation/Stop” mode or “Forced stop” mode can be selected with function setting of 

indoor unit.

•  A twisted pair cable (22 AWG) should be used. Maximum length of cable is 492 ft. (150 m).

•  Use an external input and output cable with appropriate external dimension, depending 

on the number of cables to be installed.

•  The wire connection should be separate from the power cable.

9387082593-01_IM.indb   8

9387082593-01_IM.indb   8

28-Oct-21   13:52:52

28-Oct-21   13:52:52

Содержание ASUH36LPAS

Страница 1: ...nnect all wiring tightly Loose wiring may cause overheating at connection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your fingers When Installing In a Ceiling or Wall Make su...

Страница 2: ... malfunction of your property 2 PRODUCT SPECIFICATION 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools are spe...

Страница 3: ...be removed Correct initial installation location is important because it is difficult to move unit after it is installed WARNING Install the air conditioner in a location which can withstand a load of at least 3 times the weight of the main unit and which will not amplify sound or vibration If the installation location is not strong enough the indoor unit may fall and cause injuries Withstandable ...

Страница 4: ...Top hooks 3 places Top holes 3 places Indoor unit Middle hooks 5 places Middle hooks 5 places 3 Attach the 10 screws 4 Attach the wire cover 2 screws 5 Attach the 4 caps 6 Attach the intake grille CAUTION Take caution when removing or installing the front panel If the front panel falls there is a risk of injury 3 3 Pipe installation 3 3 1 Indoor unit piping direction The piping can be connected in...

Страница 5: ... the drain hose so that it is at the bottom of the piping Install the piping so that the drain hose is at the bottom Connection cable GOOD PROHIBITED Vinyl tape Connection pipe Drain hose Connection pipe Saddle Drain hose Lifted up For Left rear piping Drain hose Left piping Drain hose Left bottom piping Drain hose Interchange the drain cap and the drain hose Installing the drain cap Use a hexagon...

Страница 6: ... pipe with a sharp cutter as shown on the right and bend it after exposing the pipe After bending the pipe as you want be sure to put the heat insu lating pipe back on the pipe and secure it with tape Pipe Insulating pipe Cutter Cut line Flare connection CAUTION Be sure to install the pipe against the port on the indoor unit correctly If the center ing is improper the flare nut cannot be tightened...

Страница 7: ...ightened 5 Do not tighten the terminal screws too much otherwise the screws may break Screw with special washer Wire Ring terminal Terminal blocks Wire Screw with special washer Ring terminal 6 Refer to the following table for the terminal screw tightening torques Tightening torque lbf in N m M3 5 screw 7 0 to 8 8 0 8 to 1 0 M4 screw 10 6 to 15 9 1 2 to 1 8 M5 screw 17 7 to 26 5 2 0 to 3 0 To conn...

Страница 8: ...oller turn off 2 Press down MODE for more than 5 seconds The current custom code will be displayed initially set to 3 Press TEMP SELECT to change the custom code between A B C D Match the custom code on the display to the air conditioner custom code 4 Press MODE again The custom code will be set The display will return to the original display To change the air conditioner custom code contact an au...

Страница 9: ...ble Use crimp type insulated butt connector to join field cable and wire kit wire Connect the wire with connecting wire with solder IMPORTANT Be sure to insulate the connection between the wires Locally purchased External connect kit option Solder and insulate the connected parts 4 1 3 Installing the External input output PCB 1 Remove the Intake grille front panel and control cover Refer to 3 2 Re...

Страница 10: ... code The custom code that is set through this process are applicable only to the custom in the function setting 1 Press TEMP SELECT to change the custom code between A B C D Match the code on the display to the air conditioner custom code initially set to If the custom code does not need to be selected press MODE and proceed to STEP 2 2 Press MODE to accept the custom code and proceed to STEP 2 T...

Страница 11: ...tory setting Function number Setting value Setting description 61 00 Auxiliary heater control 1 01 Auxiliary heater control 2 02 Heat pump prohibition control 03 Heater selection control using outdoor temperature 1 04 Heater selection control using outdoor temperature 2 05 Auxiliary heater control by outdoor temperature 3 06 Auxiliary heat pump control 07 Auxiliary heat pump control by outdoor tem...

Страница 12: ... 1 Is operation of each button on the remote control unit normal 2 Does each lamp light normally 3 Do air flow direction louvers operate normally 4 Is the drain normal 5 Do not have an abnormal noise and vibration during operation 6 Is there an error left in the error memory After installation check that the display is 00 normal For checking whether the display shows 00 refer to Service check in t...

Страница 13: ...ting error 2 7 27 Primary unit secondary unit setup error simultaneous multi split type 2 9 29 Connection unit number error in wired remote controller system 3 1 31 Power supply interruption error 3 2 32 Indoor unit PCB model information error Error display Error code Description LED1 green LED2 orange LED3 green 3 3 33 Indoor unit motor electricity consumption detection error 3 5 35 Manual auto s...

Страница 14: ...or Information Page 1 5 Address Error Code Back Next Page How to check the error memory When an error occurs the operation lamp Green and the timer lamp Orange indicate the error content by blinking To check the error memory follow the procedures below 1 Stop the operation of the air conditioner and then disconnect the power supply 2 Reconnect the power supply 3 In one of the following two methods...

Отзывы: