En-2

 CAUTION

This manual describes how to install the indoor unit only. To install the outdoor unit or 

branch box, (if any), refer to the installation manual included in each product.

2.3. For authorized service personnel only.

 WARNING

•   For appropriate working of the air conditioner, install it as outlined in this manual.

•   To connect the indoor unit and outdoor unit or branch box, use air conditioner piping 

and cables available through your local distributor. This manual describes proper 

connections using such installation set.

•   Do not reconnect the power until all work has been completed.

 CAUTION

This installation manual describes how to install the indoor unit only. 

To install the outdoor unit or branch box, refer to the installation manual included with 

the outdoor unit or branch box.

•  Be careful not to scratch the air conditioner when handling it.

•  After installation, explain correct operation to the customer, using the operation manual.

2.4. Accessories

The following installation accessories are supplied. Use them as required.

Name and Shape

Qty

Name and Shape

Qty

Operation manual

1

Tapping screw (large)

8

Installation manual  

(This manual)

1

Tapping screw (small)

2

Remote controller

1

Battery

2

Remote controller holder

1

Wall hook bracket

1

Cloth tape

1

Ion deodorization filter

(light blue)

1

Filter holder

2

Apple-catechin filter

(White)

1

Drain hose insulation

1

The following items are necessary to install this air conditioner. (The items are not includ-

ed with the air conditioner and must be purchased separately.)

Additional materials

Connection pipe assembly

Saddle

Connection cable (4-conductor)

Drain hose

Wall pipe

Tapping screw

Decorative tape

Sealant

Vinyl tape

Putty

Wall cap

2.5. Pipe requirement

 CAUTION

Refer to the installation manual for the outdoor unit for description of allowable pipe length 

and height difference.

Liquid pipe size <thickness>

Gas pipe size <thickness>

Φ3/8in (Φ9.52mm)

<1/16in(0.80mm)>

Φ5/8in (Φ15.88mm)

<1/16in(0.80mm)>

 CAUTION

•   Do not attempt to install the air conditioner or a part of the air conditioner by yourself.

•   This unit must be installed by qualified personnel with a capacity certificate for han

-

dling refrigerant fluids. Refer to regulation and laws in use on installation place.

•   This unit is part of a set constituting an air conditioner. It must not be installed alone or 

with a device non-authorized by the manufacturer.

•   Always use a separate power supply line protected by a circuit breaker operating on 

all wires with a distance between contact of 1/8 in (3 mm) for this unit.

•   The unit must be correctly grounded (earthed) and the supply line must be equipped 

with a differential breaker in order to protect the persons.

•   The units are not explosion proof and therefore should not be installed in explosive 

atmosphere.

•   When moving, consult authorized service personnel for disconnection and installation 

of the unit.

•   Do not place any other electrical products or household belongings under indoor unit 

or outdoor unit. 

   Dripping condensation from the unit might get them wet, and may cause damage or 

malfunction of your property.

2.  PRODUCT SPECIFICATION

2.1. Precautions for using R410A refrigerant

The basic installation work procedures are the same as conventional refrigerant 

(R22) models.

However, pay careful attention to the following points:

•   Since the working pressure is 1.6 times higher than that of conventional refrigerant 

(R22) models, some of the piping and installation and service tools are special. (Refer 

to the following table.)

   Especially, when replacing a conventional refrigerant (R22) model with a new refriger-

ant R410A model, always replace the conventional piping and flare nuts with the 

R410A piping and flare nuts.

•   Models that use refrigerant R410A have a different charging port thread diameter to 

prevent erroneous charging with conventional refrigerant (R22) and for safety. There-

fore, check beforehand. [The charging port thread diameter for R410A is 1/2-20 UNF.]

•   Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with 

refrigerant (R22) models. Also, when storing the piping, securely seal the opening by 

pinching, taping, etc.

•   When charging the refrigerant, take into account the slight change in the composition 

of the gas and liquid phases. And always charge from the liquid phase where refriger-

ant composition is stable.

2.2. Installation tools

Tool name

Contents of change

Gauge manifold

Pressure is high and cannot be measured with a R22 

gauge. To prevent erroneous mixing of other refrigerants, 

the diameter of each port has been changed.

It is recommended the gauge with seals -30 inHg to 768 psi 

(-0.1 to 5.3 MPa) for high pressure.

-30 inHg to 551 psi (-0.1 to 3.8 MPa) for low pressure.

Charge hose

To increase pressure resistance, the hose material and base 

size were changed.

Vacuum pump

A conventional vacuum pump can be used by installing a 

vacuum pump adapter.

Gas leakage detector

Special gas leakage detector for HFC refrigerant R410A.

 

Copper pipes

It is necessary to use seamless copper pipes and it is desirable that the amount of residual 

oil is less than 0.004 oz/100 ft. (40 mg/10 m). Do not use copper pipes having a collapsed, 

deformed or discolored portion (especially on the interior surface). Otherwise, the expansion 

value or capillary tube may become blocked with contaminants.

As an air conditioner using R410A incurs pressure higher than when using R22, it is nec-

essary to choose adequate materials. 

 WARNING

•  Do not use the existing (for R22) piping and flare nuts.

   If the existing materials are used, the pressure inside the refrigerant cycle will rise 

and cause failure, injury, etc. (Use the special R410A materials.)

•   Use (refill or replace with) specified refrigerant (R410A) only. Use of unspecified 

refrigerant can cause product malfunction, burst, or injury.

•   Do not mix any gas or impurities except specified refrigerant (R410A). Inflow of air 

or application of unspecified material makes the internal pressure of the refrigerant 

cycle too high, and may cause product malfunction, burst of piping, or injury.

•   For installation purposes, be sure to use the parts supplied by the manufacturer or 

other prescribed parts. The use of non-prescribed parts can cause serious accidents 

such as the unit falling, water leakage, electric shock, or fire.

•  Do not turn on the power until all work has been completed.

9387082593-01_IM.indb   2

9387082593-01_IM.indb   2

28-Oct-21   13:52:44

28-Oct-21   13:52:44

Содержание ASUH36LPAS

Страница 1: ...nnect all wiring tightly Loose wiring may cause overheating at connection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your fingers When Installing In a Ceiling or Wall Make su...

Страница 2: ... malfunction of your property 2 PRODUCT SPECIFICATION 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools are spe...

Страница 3: ...be removed Correct initial installation location is important because it is difficult to move unit after it is installed WARNING Install the air conditioner in a location which can withstand a load of at least 3 times the weight of the main unit and which will not amplify sound or vibration If the installation location is not strong enough the indoor unit may fall and cause injuries Withstandable ...

Страница 4: ...Top hooks 3 places Top holes 3 places Indoor unit Middle hooks 5 places Middle hooks 5 places 3 Attach the 10 screws 4 Attach the wire cover 2 screws 5 Attach the 4 caps 6 Attach the intake grille CAUTION Take caution when removing or installing the front panel If the front panel falls there is a risk of injury 3 3 Pipe installation 3 3 1 Indoor unit piping direction The piping can be connected in...

Страница 5: ... the drain hose so that it is at the bottom of the piping Install the piping so that the drain hose is at the bottom Connection cable GOOD PROHIBITED Vinyl tape Connection pipe Drain hose Connection pipe Saddle Drain hose Lifted up For Left rear piping Drain hose Left piping Drain hose Left bottom piping Drain hose Interchange the drain cap and the drain hose Installing the drain cap Use a hexagon...

Страница 6: ... pipe with a sharp cutter as shown on the right and bend it after exposing the pipe After bending the pipe as you want be sure to put the heat insu lating pipe back on the pipe and secure it with tape Pipe Insulating pipe Cutter Cut line Flare connection CAUTION Be sure to install the pipe against the port on the indoor unit correctly If the center ing is improper the flare nut cannot be tightened...

Страница 7: ...ightened 5 Do not tighten the terminal screws too much otherwise the screws may break Screw with special washer Wire Ring terminal Terminal blocks Wire Screw with special washer Ring terminal 6 Refer to the following table for the terminal screw tightening torques Tightening torque lbf in N m M3 5 screw 7 0 to 8 8 0 8 to 1 0 M4 screw 10 6 to 15 9 1 2 to 1 8 M5 screw 17 7 to 26 5 2 0 to 3 0 To conn...

Страница 8: ...oller turn off 2 Press down MODE for more than 5 seconds The current custom code will be displayed initially set to 3 Press TEMP SELECT to change the custom code between A B C D Match the custom code on the display to the air conditioner custom code 4 Press MODE again The custom code will be set The display will return to the original display To change the air conditioner custom code contact an au...

Страница 9: ...ble Use crimp type insulated butt connector to join field cable and wire kit wire Connect the wire with connecting wire with solder IMPORTANT Be sure to insulate the connection between the wires Locally purchased External connect kit option Solder and insulate the connected parts 4 1 3 Installing the External input output PCB 1 Remove the Intake grille front panel and control cover Refer to 3 2 Re...

Страница 10: ... code The custom code that is set through this process are applicable only to the custom in the function setting 1 Press TEMP SELECT to change the custom code between A B C D Match the code on the display to the air conditioner custom code initially set to If the custom code does not need to be selected press MODE and proceed to STEP 2 2 Press MODE to accept the custom code and proceed to STEP 2 T...

Страница 11: ...tory setting Function number Setting value Setting description 61 00 Auxiliary heater control 1 01 Auxiliary heater control 2 02 Heat pump prohibition control 03 Heater selection control using outdoor temperature 1 04 Heater selection control using outdoor temperature 2 05 Auxiliary heater control by outdoor temperature 3 06 Auxiliary heat pump control 07 Auxiliary heat pump control by outdoor tem...

Страница 12: ... 1 Is operation of each button on the remote control unit normal 2 Does each lamp light normally 3 Do air flow direction louvers operate normally 4 Is the drain normal 5 Do not have an abnormal noise and vibration during operation 6 Is there an error left in the error memory After installation check that the display is 00 normal For checking whether the display shows 00 refer to Service check in t...

Страница 13: ...ting error 2 7 27 Primary unit secondary unit setup error simultaneous multi split type 2 9 29 Connection unit number error in wired remote controller system 3 1 31 Power supply interruption error 3 2 32 Indoor unit PCB model information error Error display Error code Description LED1 green LED2 orange LED3 green 3 3 33 Indoor unit motor electricity consumption detection error 3 5 35 Manual auto s...

Страница 14: ...or Information Page 1 5 Address Error Code Back Next Page How to check the error memory When an error occurs the operation lamp Green and the timer lamp Orange indicate the error content by blinking To check the error memory follow the procedures below 1 Stop the operation of the air conditioner and then disconnect the power supply 2 Reconnect the power supply 3 In one of the following two methods...

Отзывы: