3.3.3. Installing the wall hook bracket

(1)  Install the wall hook bracket so that it is correctly positioned horizontally and vertically. 

If the wall hook bracket is titled, water will drip to the 

fl

 oor.

(2)  Install the wall hook bracket so that it is strong enough to support the weight of the unit.

• Fasten the wall hook bracket to the wall with 5 or more screws through the holes near 

the outer edge of the bracket.

• Check that there is no rattle at the wall hook bracket.

Wall hook bracket

Tapping screws (large, accessories)

 CAUTION

Install the wall hook bracket both horizontally and vertically aligned. 
Misaligned installation may cause water leakage.

3.3.4. Forming the drain hose and pipe

 CAUTION

•  Insert drain hose and drain cap securely. Drain should slope down to avoid water leakage.

•  When inserting the drain hose, no other material than water should be applied. 

Application of other material than water will cause deterioration of the hose, and may 

cause water leakage.

•  After you remove a drain hose, be sure to attach the drain cap.

•  When you secure the piping and drain hose with tape, arrange the drain hose so that 

it is at the bottom of the piping.

•  For drain hose piping in low temperature environment, you need to apply freeze 

protection to prevent a frozen drain hose. 

After cooling operation is performed in low temperature environment (when outdoor 

temperature under 32 °F [0 °C]), water in the drain hose could be frozen. Frozen 

drain water will block the water 

fl

 ow in the hose, and may cause water leakage at the 

indoor unit.

 

 

Right rear piping, Right piping, Right bottom piping

• Install the indoor unit piping in the direction of the wall hole and bind the drain hose 

and pipe together with vinyl tape.

• Install the piping so that the drain hose is at the bottom.
• Wrap the pipes of the indoor unit that are visible from the outside with decorative tape.

 

 

For Left rear piping (Drain hose), Left piping (Drain hose), Left bottom 
piping (Drain hose)

Interchange the drain cap and the drain hose.

Right piping

Bottom piping

Bind with vinyl tape

Refrigerant pipes (top)

Rear piping

Indoor unit drain hose (bottom)

 

 

Installing the drain cap 

Use a hexagonal wrench 3/16 in (4 mm) at opposite side to insert the drain cap, till the 
drain cap contacts the tip of the drain cock.

For left outlet piping 
(Drain hose), cut 
off the piping outlet 
cutting groove with 
a hacksaw. 

Indoor unit 
drain hose

Drain cap
Remove the drain cap by pull-
ing at the projection at the end 
of the cap with pliers, etc.

No gap

Hexagonal 
wrench

Drain 

cock

Drain cap

Removing the drain hose

Remove the screw at the left of 
drain hose and pull out drain hose.

Installing the drain hose

Vertically insert the drain hose toward the 
inside, so that the drain 

fi

 xture (white) can ac-

curately align with the screw hole around the 
drain cock.
After inserting and before replacing, please 
reinstall and 

fi

 x the removed screws.

•  Please hold around the joint of the drain hose during work.
•  As the screw is inside, be sure to use screwdrivers treated with magnet.

Screw

Drain fixture

Drain hose

Screw hole

Drain cock

Drain hose

Screw

Drain fixture

• After passing the indoor piping and drain hose through the wall hole, hang the indoor unit on 

the hooks at the top and bottom of the wall hook bracket.

 CAUTION

Insert the drain hose and drain cap into the drain port, making sure that it comes 

in contact with the back of the drain port, and then mount it. If the drain hose is not 

connected properly, leaking will occur.

 

Installing the indoor unit

•  Hang the indoor unit from the hooks at the top of the wall hook bracket.
•  Insert the spacer, etc. between the indoor unit and the wall hook bracket and separate 

the bottom of the indoor unit from the wall.

Connection pipe small

Align the marks

Bend R2-3/4 (R70) with a pipe bender

Connection pipe large

Unit: in (mm)

Top hooks

Center of upper rail

(Fittings)

Bottom hooks

Indoor unit

Wall hook bracket

(Spacer)

•  After hooking the indoor unit to the top hook, hook the 

fi

 ttings of the indoor unit to the 

bottom hooks while lowering the unit and pushing it against the wall.

3.3.5. Pipe connection

 CAUTION

 Tighten the 

fl

 are nuts with a torque wrench using the speci

fi

 ed tightening method. 

Otherwise, the 

fl

 are nuts could break after a prolonged period, causing refrigerant to 

leak and generate hazardous gas if the refrigerant comes into contact with a 

fl

 ame.

 

Flaring

Use special pipe cutter and 

fl

 are tool exclusive for R410A.

(1)  Cut the connection pipe to the necessary length with a pipe cutter.
(2)  Hold the pipe downward so that cuttings will not enter the pipe and remove any burrs.
(3)  Insert the 

fl

 are nut (always use the 

fl

 are nut attached to the indoor unit(s) and outdoor 

unit respectively) onto the pipe and perform the 

fl

 are processing with a 

fl

 are tool. Use the 

special R410A 

fl

 are tool, or the conventional 

fl

 are tool. Leakage of refrigerant may result if 

other 

fl

 are nuts are used.

(4)  Protect the pipes by pinching them or with tape to prevent dust, dirt, or water from 

entering the pipes. 

Die

A

Pipe

B

L

Check if [L] is flared uniformly 
and is not cracked or scratched.

9387603095_IM.indb   5

9387603095_IM.indb   5

2019/11/18   15:54:54

2019/11/18   15:54:54

Содержание ASUG09LZAS

Страница 1: ... death Earth Ground the unit following local electrical codes Connect all wiring tightly Loose wiring may cause overheating at connection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner c...

Страница 2: ...pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools are special Refer to the following table Especially when replacing a conventional refrigerant R22 model with a new refriger ant R410A model always replace the conventional piping and flare nuts with the R...

Страница 3: ...where connection to the outdoor unit or branch box is easy 6 Install the unit where the drain pipe can be easily installed 7 Take servicing etc into consideration and leave the spaces shown in 3 1 1 Installation dimensions Also install the unit where the filter can be removed Correct initial installation location is important because it is difficult to move unit after it is installed WARNING Insta...

Страница 4: ...removing or installing the front panel If the front panel falls there is a risk of injury 3 2 3 Uninstalling the indoor unit Remove the indoor unit from the wall hook bracket as follows 1 Remove the under covers Refer to 3 2 2 Front panel control cover removal and installation 2 Insert your fingers in the opening shown in the figure While pushing down on the lower part of the opening release the h...

Страница 5: ...ith pliers etc No gap Hexagonal wrench Drain cock Drain cap Removing the drain hose Remove the screw at the left of drain hose and pull out drain hose Installing the drain hose Vertically insert the drain hose toward the inside so that the drain fixture white can ac curately align with the screw hole around the drain cock After inserting and before replacing please reinstall and fix the removed sc...

Страница 6: ... with the pipe in order to tighten the flare nut correctly Tighten the flare nuts with a torque wrench using the specified tightening method Otherwise the flare nuts could break after a prolonged period causing refrigerant to leak and generate hazardous gas if the refrigerant comes into contact with a flame Connect the piping so that the control box cover can easily be removed for servic ing when ...

Страница 7: ... until only the clock is dis played on the remote controller display 2 Press MODE for at least 5 seconds to display the cur rent custom code initially set to A 3 Press TEMP to change the custom code between A B C D Match the code on the display to the air conditioner custom code 4 Press MODE again to return to the clock display The custom code will be changed If no buttons are pressed within 30 se...

Страница 8: ...tion Wire with connector accessory for option Connector CN13 Cable clamp accessory for option Wired remote controller cable Screw large accessory for option Terminal block Tab 7 Replace the control cover front panel and Intake grille 5 FUNCTION SETTING Perform the Function setting according to the installation conditions using the remote controller CAUTION Confirm whether the wiring work for outdo...

Страница 9: ...door unit fan rotation when the outdoor unit is stopped during cooling operation Factory setting Function number Setting value Setting description 49 00 Disable 01 Enable 02 Remote controller 00 When the outdoor unit is stopped the indoor unit fan operates continuously following the setting on the remote controller 01 When the outdoor unit is stopped the indoor unit fan operates intermittently at ...

Страница 10: ...trol unit normal 2 Does each lamp light normally 3 Do air flow direction louvers operate normally 4 Is the drain normal 5 Do not have an abnormal noise and vibration during operation Do not operate the air conditioner in test run for a long time Operation method Before starting the test run wait for 1 minute after connecting the power supply By the wireless remote controller To start the test run ...

Страница 11: ...eat ex middle temp sensor error 4 4 44 Human sensor error 5 1 51 Indoor unit fan motor error 5 3 53 Drain pump error 5 4 54 Electric air cleaner reverse VDD error 5 5 55 Filter set error Error display Error code Description OPERATION lamp green TIMER lamp orange ECONOMY lamp green 5 7 57 Damper error 5 8 58 Intake grille error 5 9 59 Indoor unit fan motor 2 error Left side fan 5 10 5A Indoor unit ...

Страница 12: ...re error 13 2 J2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Error display on the indoor unit OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indicator lamp green 9387603095_IM indb 12 9387603095_IM indb 12 2019 11 18 15 54 55 2019 11 18 15 54 55 ...