Wave

FINISHING

(1) Insulate between pipes.

For rear, right, and bottom piping, overlap the connection pipe
heat insulation and indoor unit pipe heat insulation and bind
them with vinyl tape so that there is no gap.

For left and left rear piping, butt the connection pipe heat insula-
tion and indoor unit pipe heat insulation together and bind them
with and vinyl tape so that there is no gap.

For left and left rear piping, wrap the area which accommodates
the rear piping housing section with cloth tape.

For left and left rear piping, bind the connection cord to the top
of the pipe with vinyl tape.

For left and left rear piping, bundle the piping and drain hose
together by wrapping them with cloth tape over the range within
which they fit into the rear piping housing section.

(2) Temporarily fasten the connection cord along the connection pipe

with vinyl tape. (Wrap to about 1/3 the width of the tape from the
bottom of the pipe so that water does not enter.)

(3) Fasten the connection pipe to the outside wall with a saddle, etc.
(4) Fill the gap between the outside wall pipe hole and the pipe with

sealer so that rain water and wind cannot blow in.

(5) Fasten the drain hose to the outside wall, etc.

Fig. 16

Pipe

(Saddle)

(Outside wall cap)

(Sealer putty)

(Outdoors)

Fig. 15

Drain hose

GOOD

BAD

BAD

BAD

Lifted up

Saddle

End in water

Wall

Check the following:

View from indoors

Indoor unit pipe (heat insulation)

Connection pipe
(heat insulation)

Vinyl tape

Seal A

Butt connection pipe (heat
insulation) against the indoor
unit pipe (heat insulation)
and wrap with seal A so that
there is no gap.

Pipe

Drain hose

Cloth tape

Wrap with
cloth tape

Left piping

Connection cord

Pipe

Drain hose

For connection from the left rear

Connection cord

Drain hose

Wall pipe

Connection pipe

FRONT PANEL REMOVAL AND INSTALLATION

THE INTAKE GRILLE REMOVAL

(1) Open the intake grille.
(2) Pull down the knob.
(3) Lift the intake grille upward, until the axle at the top of the intake

grille is removed.

THE INTAKE GRILLE INSTALLATION

(1) The fixing axle of the intake grille is installed on the Panel.
(2) Lay down the intake grille.

THE FRONT PANEL REMOVAL

(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove four screws.
(3) The thumb is hung on the lower part as shown in the figure, and it

pulls to the front, pushing [ ] mark , and bottom hooks (two posi-
tion) is removed from wall hook bracket.

(4) The front panel bottom is pulled to the front, and bottom hooks is

removed indoor unit.

(5) The front panel is pulled to the front, raising the upper surface,

and a front panel is removed.

THE FRONT PANEL INSTALLATION

(1) Firstly, fit the lower part of the front panel, and insert top and bot-

tom hooks. (Three top sides, six bottom sides)

(2) Four screws is attached.
(3) The intake grille is attached.

Wall hook bracket

Front panel

Push

[    ] mark

Front panel

Bearing

Mounting shaft

Intake grille

Intake grille

Knob

Front panel

Screws
(4 position)

Push

INSERT

PULL

Grip

AIR CLEANING UNIT REMOVAL

(

1)  Open the intake grille, and then remove the right air filter.

(2)  Pull the air cleaning unit grip in the direction of the arrow and remove
       the unit.

AIR CLEANING UNIT INSTALLATION

(1)  Open the intake grille, and then insert the dust collection unit into the
       indoor unit.
(2)  Install the right air filter, and then close the intake grille.

Front panel

Top hook (two sides)

Top hole
 (center)

Top holes
(two sides)

Indoor unit

Bottom hole
(six position)

Top hook
(center)

Bottom hooks
(six position)

Fig. 17

Содержание ASU15RLQ/AOU15RLQ

Страница 1: ...des Connect all wiring tightly Loose wiring may cause overheating at con nection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your fingers When Installing In a Ceiling or Wall ...

Страница 2: ...o 38 bar for low pressure To increase pressure resistance the hose material and base size were changed A conventional vacuum pump can be used by installing a vacuum pump adapter Special gas leakage detector for HFC refrigerant R410A Tool name Gauge manifold Charge hose Vacuum pump Gas leakage detector Copper pipes It is necessary to use seamless copper pipes and it is desirable that the amount of ...

Страница 3: ... the table below Between 49 ft 15 m and 66 ft 20 m when using a connection pipe other than that in the table charge additional refrigerant with 0 2 oz ft 20g 1 m as the criteria 2 ADDITIONALMATERIALSREQUIREDFOR INSTALLATION A Refrigeration armored tape B Insulated staples or clamps for connecting wire See your local electrical codes C Putty D Refrigeration lubricant E Clamps or saddles to secure r...

Страница 4: ...rear and both sides WARNING Install at a place that can withstand the weight of the indoor and outdoor units and install positively so that the units will not topple or fall CAUTION 1 Do not install where there is the danger of com bustible gas leakage 2 Do not install near heat sources 3 If children under 10 years old may approach the unit take preventive measures so that they can not reach the u...

Страница 5: ...ht hand side Rear piping Right piping Bottom piping Install the indoor unit piping in the direction of the wall hole and bind the drain hose and pipe together with vinyl tape Fig 3 Install the piping so that the drain hose is at the bottom Wrap the pipes of the indoor unit that are visible from the outside with decorative tape For Left rear piping Left piping Interchange the drain cap and the drai...

Страница 6: ...ttings will not enter the pipe and remove the burrs 3 Insert the flare nut onto the pipe and flare the pipe with a flaring tool Check if L is flared uniformly and is not cracked or scratched L dimension Thin pipe 1 4 6 35 mm dia 1 16 1 4 to 1 7 mm Thick pipe 1 2 12 7 mm dia 5 64 1 9 to 2 2 mm Flare nut 1 4 6 35 mm dia 1 2 12 7 mm dia Tightening torque 11 57 to 13 02 ft lbs 160 to 180 kgf cm 36 17 ...

Страница 7: ... the end of pump down close the low pressure side gauge of the gauge manifold fully and stop the vacuum pump 9 Slowly loosen the valve stem of the 3 way valve When the compound pressure gauge reading reaches 0 1 0 2 MPa retighten the valve stem and disconnect the charge hose from the 3 way valve charging port If the stem of the 3 way valve is opened fully before the charge hose is disconnected it ...

Страница 8: ...Therefore be sure all wiring is tightly connected Connect wires to the matching numbers of terminals NOTE Connector trade size for this unit is 1 2 12 7 mm The connec tor can be bought at a hardware store Refer to How to connect wiring to the terminals for instructions on connecting depend ing on the wire type you are using The fuse located in the outdoor unit provides power supply pro tection and...

Страница 9: ...lamp Connection cord Screw Connection cord Screw Cord clamp A For solid core wiring or F cable 1 Cut the wire end with a wire cutter or wire cutting pliers then strip the insulation to about 15 16 25 mm to expose the solid wire 2 Using a screwdriver remove the terminal screw s on the terminal board 3 Using pliers bend the solid wire to form a loop suitable for the termi nal screw 4 Shape the loop ...

Страница 10: ...with cloth tape Left piping Connection cord Pipe Drain hose For connection from the left rear Connection cord Drain hose Wall pipe Connection pipe FRONT PANEL REMOVAL AND INSTALLATION THE INTAKE GRILLE REMOVAL 1 Open the intake grille 2 Pull down the knob 3 Lift the intake grille upward until the axle at the top of the intake grille is removed THE INTAKE GRILLE INSTALLATION 1 The fixing axle of th...

Страница 11: ...atched by parts or draw it hard Or it may result troubles to the air conditioner 4 Avoid place in direct sunlight 5 Select place that will not be affected by the heat from a stove etc 6 Insure the length of wire is not over the recommended maxuim length 7 Before setting up the wired remote control unit please confirm whether air conditioner can receive the signal 1 FRONT PANEL AND CONTROL UNIT REM...

Страница 12: ...wire clamper and screws to fasten wire 3 Cut off part of the control unit and thread wire through 3 FRONT PANEL AND CONTROL UNIT INSTALLATION Install Front panel and Control unit by the reverse procedures as stated in 1 FRONT PANEL AND CONTROL UNIT REMOVAL CIRCUIT BOARD SCREW CONNECTOR TO RENOTE CONNTROL UNIT CUT CLAMPER ...

Страница 13: ...ration of each button on the remote control unit normal 2 Does each lamp light normally 3 Do the air flow direction louver operate normally 4 Is the drain normal 2 OUTDOOR UNIT 1 Is there any abnormal noise and vibration during operation 2 Will noise wind or drain water from the unit disturb the neighbors 3 Is there any gas leakage Fig 18 Transmitter section Test run button PUMP DOWN OPERATION FOR...

Страница 14: ...ter unit wire harness to the terminal correctly please refer to Fig 19 to adjust the length of the part of Inter unit Wire harness ahead from conduit holder 5 1 2 140mm 15 16 25mm 15 16 25mm 4 3 16 105mm 1 1 14AWG EARTH WIRE CONDUIT PLATE CONDUIT CONNECTOR Fig 19 ...

Страница 15: ...t be affected by the heat from a stove etc 1 REMOTE CONTROL UNIT HOLDER INSTALLATION Install the remote control unit with a distance of 23 ft 7 m between the remote control unit and the photocell as the criteria However when installing the remote con trol unit check that it operates positively Install the remote control unit holder to a wall pillar etc with the tapping screw Fig 20 Remote control ...

Отзывы: