background image

En-10

OPERATING MANUAL

Care and Cleaning

 

CAUTION

• Before cleaning the indoor unit, be sure to turn it off and all the power supply has been disconnected. 
• Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an 

effect on the proper working or performance of the air conditioner.

• Do not touch the aluminum 

fi

 ns of heat exchanger built-in the indoor unit to avoid personal injury when you maintain the unit.

• Do not expose the indoor unit to liquid insecticides or hair sprays.
• Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.

Daily care

When cleaning the indoor unit body, mind the following:

• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

• Wipe the unit gently by using soft cloth.

 Cleaning the intake grille

1

  Open the intake grille in direction of the arrow 

a

. While gently 

pressing the left and right mounting shafts of the intake grille 
outward 

b

, remove the intake grille in direction of the arrow 

c

.

a

a

b

c

b

c

2

  Wash the intake grille gently with water or wipe it gently with a 

soft cloth moisten with warm water.

 

Then wipe it with a dry and soft cloth.

3

  While holding the grille horizontal, set the left and right mounting 

shafts into the pillow blocks at the top of the panel 

a

. To latch 

each shaft properly, insert the shaft until it snaps.

 

Then close the intake grille 

b

.

a

a

b

b

4

  Press 4 places on the intake grille to close it completely.

  Cleaning the air 

fi

 lters

Mind that you have a periodical cleaning of the air 

fi

 lters to prevent 

reducing the operation ef

fi

 ciency of the product. 

Using of clogged air 

fi

 lter with dust will lower the product performance, 

and may cause air

fl

 ow reduction or increase of operating noise. 

Clean the air 

fi

 lters once every 2 weeks under normal use.

1

  Open the intake grille.

 (Refer 

to 

a

 of step 1 in “Cleaning the intake grille”.)

2

  While holding the intake grille with your hand, pull up the handle 

of the 

fi

 lter in direction of the arrow and release the 2 claws 

b

.

Then pull the 

fi

 lter out with gently sliding it downward 

c

.

a

b

b

a

c

3

  Filter holder and air cleaning 

fi

 lter are attached on the rear side 

of the air 

fi

 lter. Remove them from the air 

fi

 lter by unlatching each 

corner of the 

fi

 lter holder 

d

.

d

d

d

d

4

  Remove dust by using a vacuum cleaner or by washing the 

fi

 lter.

When you wash the 

fi

 lter, use neutral household detergent and 

warm water.
After rinse the 

fi

 lter well, dry it throughly in a shaded place before 

you reinstall it.

5

  Attach the air cleaning 

fi

 lter and the 

fi

 lter holder to each air 

fi

 lter.

6

  Attach the air 

fi

 lter with aligning both side of the 

fi

 lter with the front 

panel, and push in the 

fi

 lter fully.

Note:

 

Make sure that 2 claws are 

fi

 rmly snapped to the guide holes on 

the panel.

7

  Close the intake grille 

fi

 rmly.

(Refer to step 4 in “Cleaning the intake grille”.)

9320455002_OM_EN.indd   10

9320455002_OM_EN.indd   10

7/23/2013   10:34:48 AM

7/23/2013   10:34:48 AM

Содержание ASTG18KMCA

Страница 1: ...ce personnel In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in ...

Страница 2: ... items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or cover...

Страница 3: ...6 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 8 In SWING operation power diffuser does not move 7 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizon...

Страница 4: ... not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up the r...

Страница 5: ...CK button Used for adjusting the timer setting 17 RESET button When you press the RESET button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this figure RESET See page 2 18 CLOCK ADJUST button Used for adjusting the clock 19 SEND button Used for sending the timer clock setting See page 6 20 TIMER SETTING button Used to enter the timer se...

Страница 6: ...or cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed In HEAT mode Set temperature Set time 1 hour Set time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode WEEKLY timer ON and OFF timer can be combined and up to 4 reservations prog...

Страница 7: ...s the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer select No Timer Operation in Step 5 in the ...

Страница 8: ... such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to t...

Страница 9: ...ices Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat fr...

Страница 10: ...the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating ...

Страница 11: ...the filter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization filter UTR FA16 2 Light blue 1 sheet The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as f...

Страница 12: ...minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 9 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped ...

Отзывы: