AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

General Informations on Operation

 Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost 
may form on the outdoor unit during the heating operation, and 
it could reduce the operating performance of the product. 
For frost protection, a microcomputer-controlled automatic 
defrost function is equipped in this air conditioner. 
If frost forms, the air conditioner will temporarily stop, and 
defrost circuit will operate brie

fl

 y (maximum of 15 minutes.)

OPERATION indicator on the indoor unit blinks during this 
operation. 
If frost forms on the outdoor unit after the heating operation, the 
outdoor unit will stop automatically after it operates for a few 
minutes. Then the automatic defrosting operation starts.

 Auto-restart function

In event of power interruption such as a blackout, the air 
conditioner stops once. But it restarts automatically and 
performs previous operation when the power supply is resumed.

If any power interruption occurs after the timer is set, counting 
down of the timer will be reset. 
After the power supply is resumed, the TIMER indicator on the 
indoor unit blinks to notify you that there has been a timer fault. 
In such a case, reset the timer for your opportune time.

Malfunctions caused by other electrical devices:

Use of other electrical appliances such as an electric shaver or 
nearby use of a wireless radio transmitter may cause the malfunction 
of the air conditioner. 
If you encounter such a malfunction, turn off the circuit breaker once. 
Then turn it on again, and resume operation by using the remote 
controller.

Heating performance

• This air conditioner operates on the heat-pump principle, 

absorbing heat from air outdoors and transferring that heat 
to the indoor unit. As a result, the operating performance is 
reduced as outdoor air temperature drops. If you feel that the 
heating performance is insuf

fi

 cient, we recommend you to use 

this air conditioner in conjunction with other kinds of heating 
appliance.

Temperature and Humidity Range

Permissible ranges of temperature and humidity are as follows:

COOL/DRY

Indoor temperature

About 18 °C to 32 °C

Indoor humidity

Below approximately 80%.
If the air conditioner is used continuously for many 
hours, water may condense on the surface and drip.

HEAT

Indoor temperature

About 16 °C to 30 °C

If the unit is used under higher temperature conditions than those noted here, the automatic protection circuit may operate, interrupting the operation.
If the unit is used under lower temperature conditions than those noted here, the heat exchanger may freeze, causing water leakage or other mal-
function.

  Do not use the air conditioner for any purpose other than room cooling/dry, room heating or fan.

9333003283-02_OM_EN.indd   9

9333003283-02_OM_EN.indd   9

2017/11/29   10:24:11

2017/11/29   10:24:11

Содержание ASTG09KMCB

Страница 1: ...leakage be sure to keep away from fire or any flammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuously operating ign...

Страница 2: ...hose items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or c...

Страница 3: ...rn to position 3 Keeping the position 4 7 during COOL or DRY mode may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 8 Drain h...

Страница 4: ... is not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up th...

Страница 5: ...use because it will cause incorrect operation During the test run the OPERATION indicator and the TIMER indicator blink simultaneously To quit the test run that is started unintentionally you need to turn off the air conditioner by pressing the START STOP button See page 2 18 CLOCK ADJUST button Used for adjusting the clock 19 SEND button Used for sending the timer clock setting See page 6 20 TIME...

Страница 6: ...operation Note for timer settings Any interruption of the power supply such as a blackout or cutting off of a circuit breaker makes the set internal clock incorrect In such a case the TIMER indicator on the indoor unit blinks and you need to readjust the setting Timer Operation ON timer or OFF timer You can set the ON timer or OFF timer with the following steps 1 Press the TIMER SETTING button to ...

Страница 7: ...nd OFF timer can be combined and up to 4 reservations program per day and 28 reservations per week Before setting the program please set the week and time of the air con ditioner first If the week and time are not set the weekly timer will not operate cor rectly at the set time Please refer to remote controller preparation page 2 Example of WEEKLY timer 1 No timer settings Program 9 00 OFF Program...

Страница 8: ...n the room the set temperature will not be changed This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to th...

Страница 9: ...ces Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat fro...

Страница 10: ...he shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating n...

Страница 11: ...g absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as follows 1 Remove the filter 2 Flush the filter with high pressure hot water until the surface of the filter is covered with water 3 Wash the filter gently with diluent neutral detergent Do not wash it by wringing o...

Страница 12: ...to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Outdoor unit emits water During heating operation the outdoor un...

Отзывы: