background image

En-3

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

1 Intake 

grille

Before starting operation, make sure that the intake grille has been 
shut completely. Incomplete closing may have an effect on the proper 
function or performance of the product.

2  MANUAL AUTO button

Use when the remote controller is lost or there is a malfunction.

Status

Action

Mode or operation

In operation

Press more than 3 seconds.

Stop

Stopping

Press more than 3 seconds and 

less than 10 seconds.

AUTO

Press more than 10 seconds.

(Only for servicing.*)

Forced cooling

After cleaning

Press less than 3 seconds.

Filter indicator reset

*:To stop forced cooling, press this button or START/STOP button on 

the remote controller.

3  Wireless LAN control indicator and buttons

WLAN adapter is build-in for wireless LAN control.
For details, refer to the setting manual of the Wireless LAN control.

NOTES:

• The indicators can be turned off by using the mobile app.

4 Front 

panel

See page 8

5 Human 

Sensor

Used for Energy Saving Program. Controls temperature setting by 
detecting people in the room.

6 Vertical 

air

fl

 ow direction louver

Each time you press SET button on the remote controller, the angle 
of the vertical air

fl

 ow direction louver moves as follows:

1

2

3

4

5

6 7

COOL or DRY mode

HEAT mode

1

2

3

7

6

5

*

*

4

*: Default setting in each mode.

• Do not adjust by hand.
• At the beginning of AUTO or HEAT mode, they may stay on position 

1 for a while for adjustment.

• If the angle is set to position 4–7 for more than 30 minutes in COOL 

or DRY mode, the louver will automatically return to position 3.

•  Keeping the position 4-7 during COOL or DRY mode may cause 

condensation to form, and the drops may damage your property.

7 Power 

diffuser

In conjunction with movement of the vertical air

fl

 ow direction louver, 

the angle of the power diffuser moves as follows:

Vertical air

fl

 ow 

direction louver

Power diffuser

3

7

6

5

4

2

1

3

2

1

4

• In SWING operation, power diffuser does not move.

8 Drain 

hose

9  Remote controller signal receiver

 

CAUTION

For appropriate signal transmission between remote controller and 
indoor unit, keep the signal receiver away from the following items:

 

- Direct sunlight or other strong lights

 

- Flat-panel television screen

In rooms with instantaneous 

fl

 uorescent lights, such as in-

verter type ones, the signal may not be transmitted properly. In 
such a case, consult the store of purchase.

10  ECONOMY indicator (green)

Lights in ECONOMY operation and in 10 °C HEAT operation.

11  TIMER indicator (orange)

Lights in TIMER operation, and blinks slowly when the timer setting 
error is detected.
For details, refer to “Auto-restart function” on page 9.

8

1

4

5

6

7

10

11

12

13

15

2

14

9

3

12  OPERATION indicator (green)

Lights in normal operation, and blinks slowly in Automatic defrosting 
operation.
Blinks during Demand Response operation. For details, refer to page 
8.

13  Horizontal air

fl

 ow direction louvers

 

CAUTION

Before you adjust the horizontal air

fl

 ow direction, make sure that 

the vertical air

fl

 ow direction louver has been stopped completely.

Adjust two knobs by hand.

See page 10

14  Air 

fi

 lter

See page 11

15  Air cleaning 

fi

 lters

Purify or deodorize the air, and provide fresh air

fl

 ow.

Indoor Unit Overview and Operations

9333003283-02_OM_EN.indd   3

9333003283-02_OM_EN.indd   3

2017/11/29   10:24:08

2017/11/29   10:24:08

Содержание ASTG09KMCB

Страница 1: ...leakage be sure to keep away from fire or any flammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuously operating ign...

Страница 2: ...hose items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or c...

Страница 3: ...rn to position 3 Keeping the position 4 7 during COOL or DRY mode may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 8 Drain h...

Страница 4: ... is not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up th...

Страница 5: ...use because it will cause incorrect operation During the test run the OPERATION indicator and the TIMER indicator blink simultaneously To quit the test run that is started unintentionally you need to turn off the air conditioner by pressing the START STOP button See page 2 18 CLOCK ADJUST button Used for adjusting the clock 19 SEND button Used for sending the timer clock setting See page 6 20 TIME...

Страница 6: ...operation Note for timer settings Any interruption of the power supply such as a blackout or cutting off of a circuit breaker makes the set internal clock incorrect In such a case the TIMER indicator on the indoor unit blinks and you need to readjust the setting Timer Operation ON timer or OFF timer You can set the ON timer or OFF timer with the following steps 1 Press the TIMER SETTING button to ...

Страница 7: ...nd OFF timer can be combined and up to 4 reservations program per day and 28 reservations per week Before setting the program please set the week and time of the air con ditioner first If the week and time are not set the weekly timer will not operate cor rectly at the set time Please refer to remote controller preparation page 2 Example of WEEKLY timer 1 No timer settings Program 9 00 OFF Program...

Страница 8: ...n the room the set temperature will not be changed This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to th...

Страница 9: ...ces Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat fro...

Страница 10: ...he shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating n...

Страница 11: ...g absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as follows 1 Remove the filter 2 Flush the filter with high pressure hot water until the surface of the filter is covered with water 3 Wash the filter gently with diluent neutral detergent Do not wash it by wringing o...

Страница 12: ...to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Outdoor unit emits water During heating operation the outdoor un...