background image

En-1

PART No. 9333003016

AIR CONDITIONER
Wall Mounted Type

ASTG09KMCA
ASTG12KMCA

OPERATING MANUAL

Before using this product, read these instructions thoroughly and keep this manual for future reference.

Safety Precautions

To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the 
following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classi

fi

 ed as follows:

 

WARNING

 

CAUTION

This mark warns of death or serious injury.

This mark warns of injury or damage to property.

 This mark denotes an action that is PROHIBITED.

 This mark denotes an action that is COMPULSORY.

• Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this appliance uses a 

fl

 ammable refrigerant. If the refrigerant is leaked and exposure to an external 

ignition source, there is a risk of 

fi

 re.

CAUTION

This symbol shows that the Operation Manual should be read carefully.

CAUTION

This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.

CAUTION

This symbol shows that information is available such as the Operating Manual or Installation Manual.

 

WARNING

• The appliance contains no user-serviceable parts. Always 

consult authorized service personnel for repairing, installation, 
and relocation of this product.

  Improper installation or handling will cause leakage, electric 

shock, or 

fi

 re.

• In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 
disconnect all the power supply by turning off the electrical 
breaker or disconnecting the power plug. Then consult 
authorized service personnel.

• Take care not to damage the power supply cable.
  If it is damaged, it should only be replaced by authorized 

service personnel.

• In the event of refrigerant leakage, be sure to keep away 

from 

fi

 re or any 

fl

 ammables, and consult authorized service 

personnel.

• If you see lightning or hear thunder, there might be a lightning 

strike.

  To prevent electric shock hazard, turn off the air conditioner 

by using the remote controller, and do not touch the unit or 
the power plug during thunderstorm.

• The appliance shall be stored in a room without continuously 

operating ignition sources (for example: open 

fl

 ames, an 

operating gas appliance or an operating electric heater).

• The appliance shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical 

damage from occurring.

• Disposing of the product shall be done properly, in 

compliance with national or regional regulations.

• During transportation or relocation of the indoor unit, pipes 

shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the 

fl

 ammable gas to leak during operation).

• This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning use of 
the appliance by a person responsible for their safety.

• Children should be supervised to ensure that they do not play 

with the appliance.

(continued)

Contents

Safety Precautions ..........................................................En-1

Indoor Unit Overview and Operations .............................En-3

Remote Controller Overview and Operations ..................En-4

Timer Operation...............................................................En-6

Human Sensor (Energy Saving) ......................................En-8

Demand Response and Indoor Unit Operation ...............En-8

General Informations on Operation .................................En-9

Care and Cleaning.........................................................En-10

Troubleshooting .............................................................En-12

R32

REFRIGERANT

This Air Conditioner contains and 
operates with refrigerant R32.

THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.

Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before 
the installation, maintenance or service of this product.

9333003016_OM_EN.indd   1

9333003016_OM_EN.indd   1

7/1/2013   10:39:49 AM

7/1/2013   10:39:49 AM

Содержание ASTG09KMCA

Страница 1: ...re to keep away from fire or any flammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuously operating ignition sources...

Страница 2: ...e items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or cove...

Страница 3: ...s may damage your property 6 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropriate signal transmission between remote controller...

Страница 4: ... not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up the r...

Страница 5: ... other small object in correct direction as shown in this figure RESET See page 2 17 CLOCK ADJUST button Used for adjusting the clock 18 SEND button Used for sending the timer clock setting See page 6 19 TIMER SETTING button Used to enter the timer setting mode 20 SELECT button Used for adjusting the clock or timer 21 OUTDOOR UNIT LOW NOISE button Starts or stops OUTDOOR UNIT LOW NOISE operation t...

Страница 6: ...rming or cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed In HEAT mode Set temperature Set time 1 hour Set time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode WEEKLY timer ON and OFF timer can be combined and up to 4 reservation...

Страница 7: ...ress the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer select No Timer Operation in Step 5 in t...

Страница 8: ... in the room the set temperature will not be changed This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to ...

Страница 9: ...vices Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat f...

Страница 10: ... the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating...

Страница 11: ... the filter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization filter UTR FA16 2 Light blue 1 sheet The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as ...

Страница 12: ... minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 9 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped...