background image

En-2

OPERATING MANUAL

 

WARNING

• Do not install the unit in area 

fi

 lled with mineral oil such as a 

factory or area containing a large amount of splashed oil or 
steam such as a kitchen.

• Do not start or stop the operation of this product by inserting 

or pulling out the power plug, or by turning on or off the 
circuit breaker.

• Do not use in

fl

 ammable gases near the unit.

• Do not expose yourself directly to the cooling air

fl

 ow for 

many hours.

• Do not insert your 

fi

 ngers or any other objects into outlet 

port, open panel, or intake grille.

• Do not operate with wet hands.
• Do not use means to accelerate the defrosting process or to 

clean the appliance, other than those recommended by the 
manufacturer.

• Do not pierce or burn.

 

CAUTION

• Provide occasional ventilation during use.
• Always operate the unit with air 

fi

 lters installed.

• Ensure that any electronic equipment is at least 1 meter 

away from either the indoor unit or outdoor unit.

• Unplug the power supply cable when not using the indoor 

unit for an extended period.

• After long period of use, check whether the installation stand 

does not deteriorate to prevent the unit from falling down.

• The air

fl

 ow direction and the room temperature should be 

carefully considered when you use this product in a room 
with infants, children, elderly or sick persons.

• Do not place vase or water container on the unit.
• Do not place any other electrical products or household 

belongings under indoor unit or outdoor unit.

  Dripping condensation from the unit might get them wet, and 

may cause damage or malfunction of your property.

• Do not expose the unit directly to water.
• Do not use this product for preservation of food, plants, 

animals, precision equipment, art work, or other objects. This 
may cause quality deterioration of those items.

• Do not expose animals or plants to the direct air

fl

 ow.

• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable to disconnect the plug.
• Do not touch the aluminum 

fi

 ns of heat exchanger built-in 

the indoor or outdoor unit to avoid personal injury when you 
install or maintain the unit.

• Do not direct the air

fl

 ow at 

fi

 replaces or heating apparatus.

• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator 

fi

 ns.

•  Do not climb on, place objects on, or hang objects from the unit.

Safety Precautions (continued)

 Indoor unit accessories

Remote 
controller

Batteries

Air cleaning 

fi

 lters

Filter holders

Remote controller 
holder

Tapping screws
(M3 × 12 mm)

Remote controller holder installation

3

2

1

Screws

Insert

Slide up

 

WARNING

Take care to prevent infants and young children from acciden-
tally swallowing the batteries.

 

CAUTION

• Do not attempt to recharge dry batteries.
• Do not use dry batteries that has been recharged.

 

Battery (R03/LR03/AAA × 2) loading and remote controller preparation

1

4

2

3

6

7

8

5

9

5

    Press CLOCK ADJUST button to start clock setting.

6

    Set the day of the week by pressing SELECT button (Monday to 

Sunday). *By pressing the TEMP. (

∧∨

) buttons, the time indicator 

can be changed from a 24-hour to a 12-hour clock.

7

    Press NEXT button to continue.

8

    Set the time by pressing SELECT button.

Pressing 

 or 

 changes the value by the minute.

Pressing down on 

 or 

 changes the value by 10 minutes.

9

    To complete, press the SEND button close to the indoor unit. 

Settings may not be properly sent if pressed from a distance.

Notes:

•  Use speci

fi

 ed type of batteries only.

•  Do not mix different types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
•  If the remote control range noticeably shortens, replace the batter-

ies, and press RESET button as shown in page 5.

9333003016_OM_EN.indd   2

9333003016_OM_EN.indd   2

7/1/2013   10:39:58 AM

7/1/2013   10:39:58 AM

Содержание ASTG09KMCA

Страница 1: ...re to keep away from fire or any flammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuously operating ignition sources...

Страница 2: ...e items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or cove...

Страница 3: ...s may damage your property 6 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropriate signal transmission between remote controller...

Страница 4: ... not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up the r...

Страница 5: ... other small object in correct direction as shown in this figure RESET See page 2 17 CLOCK ADJUST button Used for adjusting the clock 18 SEND button Used for sending the timer clock setting See page 6 19 TIMER SETTING button Used to enter the timer setting mode 20 SELECT button Used for adjusting the clock or timer 21 OUTDOOR UNIT LOW NOISE button Starts or stops OUTDOOR UNIT LOW NOISE operation t...

Страница 6: ...rming or cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed In HEAT mode Set temperature Set time 1 hour Set time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode WEEKLY timer ON and OFF timer can be combined and up to 4 reservation...

Страница 7: ...ress the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer select No Timer Operation in Step 5 in t...

Страница 8: ... in the room the set temperature will not be changed This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to ...

Страница 9: ...vices Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat f...

Страница 10: ... the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating...

Страница 11: ... the filter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization filter UTR FA16 2 Light blue 1 sheet The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as ...

Страница 12: ... minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 9 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped...