background image

En-12

OPERATING MANUAL

 

WARNING

In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical 
breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel.
As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.

• Unit smells of something burning or emits smoke
• Water leaks from the unit

Following symptoms do not indicate product malfunction, but they are normal functions or characteristics of this product.

Symptom

Cause

See page

Operation is delayed after 
restart.

To prevent blowout of the fuse, the compressor will not operate while the protection circuit is working 
for about 3 minutes after sudden OFF

ON operation of the power supply.

Noise is heard.

• During operation or immediately after stopping the air conditioner, refrigerant 

fl

 owing sound may be 

heard. Also it may be particularly noticeable for 2–3 minutes after starting operation.

• During the operation, a slight squeaking sound produced by the minute expansion and contraction 

of the front panel caused by temperature change may be heard.

During heating operation, a sizzling sound produced by the automatic defrosting operation may be 
heard.

9

Smell coming from the unit.

Various smells generated from interior textile, furniture, or cigarette smoke absorbed into the air 
conditioner may be emitted.

Mist or steam is emitted from 
the unit.

In COOL or DRY mode, a thin mist generated by condensation formed with sudden cooling process 
may be emitted.

During heating operation, the fan built-in the outdoor unit may stop and rising steam generated by the 
automatic defrosting operation may be seen.

9

Air

fl

 ow is weak or stops.

• Immediately after the heating operation is started, the fan speed stays very low temporarily to warm 

up the internal parts of the unit.

• In HEAT mode, the outdoor unit stops and the indoor unit operates at very low fan speed if the 

room temperature rises above the set temperature.

In HEAT mode, the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic 
defrosting operation while the OPERATION indicator is 

fl

 ashing.

9

In DRY mode, the indoor unit operates at low fan speed to adjust the room humidity, and may stop 
from time to time.

When the fan speed is set to “QUIET”, the fan rotates at very low speed and the air

fl

 ow is reduced.

In COOL mode, the indoor unit fan may stop from time to time when the outdoor unit is stopped.

4

When monitoring operation is performed in AUTO mode, the fan rotates at very low speed.

Outdoor unit emits water.

During heating operation, the outdoor unit may emit water generated by the automatic defrosting 
operation.

9

Before you call for or request servicing, troubleshoot a problem by performing following checks:

Symptom

Diagnostic

See page

Does not operate at all.

 Has the circuit breaker been turned off?

 Has there been a power outage?

 Has a fuse blown out or the circuit breaker been tripped?

 Is the timer operating? 

6

Poor cooling or heating perfor-
mance.

 Is the air 

fi

 lter dirty? 

10

 Is the intake grill or outlet port of indoor unit blocked?

 Is the room temperature adjusted appropriately?

4

 Is a window or door left opened?

 Is direct or strong sunlight shinning into the room in cooling operation?

  Are there other heating apparatus or computers operating, or too many people in the room in cool-

ing operation?

  Is the fan speed set to “QUIET”?

When the fan speed setting is set to “QUIET”, noise reduction is prioritized and the air-conditioning 
performance may become lower. If the volume of provided air

fl

 ow is not agreeable to your prefer-

ence, set the fan speed to “LOW” or higher fan speed.

5

  Has the OUTDOOR UNIT LOW NOISE mode been set?

5

 Do you have an arrangement with your electric company for Demand Response?

8

The unit operates differently 
from the remote controller 
setting.

 Are the batteries used in the remote controller exhausted?

 Are the batteries used in the remote controller loaded properly?

2

Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.

• The problem persists even if you perform these checks or diagnostics.
• The OPERATION indicator and TIMER indicator blink while the ECONOMY indicator is blinking fast.

Troubleshooting

9333003016_OM_EN.indd   12

9333003016_OM_EN.indd   12

7/1/2013   10:40:08 AM

7/1/2013   10:40:08 AM

Содержание ASTG09KMCA

Страница 1: ...re to keep away from fire or any flammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuously operating ignition sources...

Страница 2: ...e items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or cove...

Страница 3: ...s may damage your property 6 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropriate signal transmission between remote controller...

Страница 4: ... not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up the r...

Страница 5: ... other small object in correct direction as shown in this figure RESET See page 2 17 CLOCK ADJUST button Used for adjusting the clock 18 SEND button Used for sending the timer clock setting See page 6 19 TIMER SETTING button Used to enter the timer setting mode 20 SELECT button Used for adjusting the clock or timer 21 OUTDOOR UNIT LOW NOISE button Starts or stops OUTDOOR UNIT LOW NOISE operation t...

Страница 6: ...rming or cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed In HEAT mode Set temperature Set time 1 hour Set time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode WEEKLY timer ON and OFF timer can be combined and up to 4 reservation...

Страница 7: ...ress the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer select No Timer Operation in Step 5 in t...

Страница 8: ... in the room the set temperature will not be changed This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to ...

Страница 9: ...vices Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat f...

Страница 10: ... the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating...

Страница 11: ... the filter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization filter UTR FA16 2 Light blue 1 sheet The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as ...

Страница 12: ... minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 9 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped...

Отзывы: