En-14
6.3.2. Checking the function settings
• Press and hold the “MANUAL AUTO” button on the indoor
unit for 3 seconds to check the function settings. It is
necessary to disconnect the power in order to return to
normal operation mode.
(1) Indoor unit and refrigerant address indication
Indication pattern
Indicator name
Indication pattern
Indoor unit address
Refrigerant address
OPERATION
indicator lamp
(Green)
ON
Flash
(1.0s ON/1.0s OFF)
TIMER
indicator lamp
(Orange)
Address: tens place
(0.5s ON/0.5s OFF)
FILTER
indicator lamp
(Red)
Address: ones place (0.5s ON/0.5s OFF)
• Indoor unit address example
(Example) ADDRESS : 24
OPERATION
indicator lamp
(Green)
TIMER
indicator lamp
(Orange)
FILTER
indicator lamp
(Red)
10 sec
1 cycle 12 sec
8 sec
ON
OFF
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
0.5s 0.5s 0.5s 0.5s
ON
OFF
ON
OFF
ON
• Refrigerant address example
(Example) ADDRESS : 30
OPERATION
indicator lamp
(Green)
TIMER
indicator lamp
(Orange)
FILTER
indicator lamp
(Red)
9 sec
1 cycle 12 sec
ON
OFF
1.0s
1.0s
1.0s
1.0s
1.0s
1.0s
1.0s
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
ON
OFF
ON
OFF
OFF
• Setting details
Function number
Item
Setting number
01
Indoor unit address
00~63
02
Refrigeration address
00~99
For use with a remote control, set all rotary switches to
0, and refer to “6.1. Setting the address” for details.
All switches are set to 0 at the factory.
(2) Others
Indication pattern
Indicator Name
Indication pattern
OPERATION
indicator lamp (Green)
Function number; tens place
(0.5s ON/0.5s OFF)
TIMER
indicator lamp
(Orange)
Function number; ones place
(0.5s ON/0.5s OFF)
FILTER
indicator lamp
(Red)
Setting number: (0 - 9)
(0.5s ON/0.5s OFF)
(Example) Function : 31, Setting number : 2
OPERATION
indicator lamp
(Green)
TIMER
indicator lamp
(Orange)
FILTER
indicator lamp
(Red)
11 sec
10 sec
9 sec
1 cycle 12 sec
ON
OFF
0.5s 0.5s
0.5s
0.5s
0.5s
0.5s
0.5s
0.5s
0.5s
0.5s 0.5s 0.5s
ON
OFF
ON
OFF
6.4. Connecting the wired remote controller
(If necessary)
In order to connect the wired/simple remote control to the
external switch controller, the wire assembly (Accessories)
which is attached to the indoor unit needs be connected to the
end of remote control cable.
(1) Use a tool to cut off the terminal on the end of the remote
control cable, and then remove the insulation from the cut
end of the cable as shown below.
Remote control
cable
20 mm
(2) Connect the remote controller cable and wire assembly as
shown below.
White
Red
White
Red
Remote
control
cable
Black
Black
Insutated
connection
(3) Connect the cable of wired remote control unit to the PCB of
Control unit.
(4) Fasten the remote control cable to the EV kit cable with the
binder as shown below.