En-5

2.5. Optional parts

Refer to each installation manual for the method of installing optional parts.

Parts name

Model No.

Application

Wired remote controller 

UTY-RNR

Z

For air conditioner operation
(2-wired type)

UTY-RLR

UTY-RVN

M

For air conditioner operation
(3-wired type)

UTY-RNN

M

Simple remote controller

UTY-RSR

For air conditioner operation
(2-wired type)

UTY-RHR

UTY-RSN

M

For air conditioner operation
(3-wired type)

IR receiver unit

UTY-LBT

M

For the wireless remote controller

Remote sensor unit

UTY-XSZX

Room temperature sensor

Auto louver grille kit

UTD-GXTA-W

Air outlet grille with outo louver 
(07, 09,12,14 models)

UTD-GXTB-W

Air outlet grille with outo louver 
(18 model)

External connect kit

PCB terminal

For control input port 

UTY-XWZXZG

For control output port

W-LAN interface

UTY-TFSXZ1

For wireless LAN control

3. INSTALLATION WORK

 WARNING

Do not move the appliance by holding the indoor unit pipes. 
(The stress applied to the pipe joints may cause the 

fl

 ammable gas to leak during 

operation.)

 3.1. Selecting an installation location

Especially, the installation place is very important for the split type air conditioner because it 
is very dif

fi

 cult to move from place to place after the 

fi

 rst installation.

 WARNING

Select installation locations that can properly support the weight of the indoor. Install 
the units securely so that they do not topple or fall.

 CAUTION

•  Do not install the unit in the following areas:

-  Area with high salt content, such as at the seaside. It will deteriorate metal parts, 

causing the parts to fail or the unit to leak water.

-  Area 

fi

 lled with mineral oil or containing a large amount of splashed oil or steam, 

such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the 
unit to leak water. 

-  Area where is close to heat sources. 
-  Area that generates substances that adversely affect the equipment, such as 

sulfuric gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed 
joints to corrode, which can cause refrigerant leakage.

-  Area that can cause combustible gas to leak, contains suspended carbon 

fi

 bers or 

fl

 ammable dust, or volatile in 

fl

 ammables such as paint thinner or gasoline.

-  If gas leaks and settles around the unit, it can cause a 

fi

 re.

-  Area where animals may urinate on the unit or ammonia may be generated.

•   Do not use the unit for special purposes, such as storing food, raising animals, grow-

ing plants, or preserving precision devices or art objects. It can degrade the quality 
of the preserved or stored objects.

•  Install the unit where drainage does not cause any trouble.
•  Install the indoor unit, outdoor unit, power supply cable, transmission cable, and 

remote control cable at least 1 m away from a television or radio receivers. The 
purpose of this is to prevent TV reception interference or radio noise.
(Even if they are installed more than 1 m apart, you could still receive noise under 
some signal conditions.)

•  If children under 10 years old may approach the unit, take preventive measures so 

that they cannot reach the unit.

• Decide the mounting position with the customer as follows:

(1)  Install the indoor unit in a location having suf

fi

 cient strength to support the weight of 

the indoor unit.

(2)  The inlet and outlet ports should not be obstructed; the air should be able to blow all 

over the room.

(3)  Leave the space required to service the air conditioner.

(4)  Locate where the air can be distributed evenly throughout the room by the unit.

(5)  Install the unit where connection to the outdoor unit is easy.

(6)  Install the unit where the connection pipe can be easily installed.

(7)  Install the unit where the drain pipe can be easily installed.

(8)  Install the unit where noise and vibration is not ampli

fi

 ed.

(9)  Take servicing, etc., into consideration and leave the spaces. Also install the unit 

where the 

fi

 lter can be removed.

 

3.2. Installation dimensions

Provide a Service access for inspection purposes. 
Do not place any wiring or illumination in the service space, as they will impede service.

Left 
side

Strong and durable ceiling

Indoor unit

Right 
side

150 mm 
or more 

400 mm 
or more

Service access

Ceiling

2500 mm or more

(When no ceiling)

Floor

240 mm or more

20 mm or more

20 mm or more

300 mm or more

Adjust the wind direction in the room depending on the shape of blow out opening.

Service access

Unit

Control 
box

400 mm 
or more

100 mm 

or more

300 mm 

or more

Service space

 

3.3. Installing the unit

 WARNING

 •  Install the air conditioner in a location which can withstand a load do at least 5 times 

the weight of the main unit and which will not amplify sound or vibration. If the instal-
lation location is not strong enough, the indoor unit may fall and cause injuries.

 •  If the work is done with the panel frame only, there is a risk that the unit will come 

loose. Please take care.

3.3.1. Unit installation example

 

Connect the locally purchased duct:

(1) Inlet side
•  Connect the duct to the locally purchased inlet 

fl

 ange.

• Connect the 

fl

 ange to the body with the locally purchased tapping screws.

• Wind the inlet 

fl

 ange connecting to the duct with the aluminum tape etc. to avoid the 

air discharge.

 CAUTION

When the duct is connected to inlet side, remove contained 

fi

 lter and surely attach 

locally purchased 

fi

 lter at inlet opening.

(2) Outlet side
•  Connect the duct with adjusting inside of outlet 

fl

 ange.

•  Wind the outlet 

fl

 ange connecting to the duct with the aluminum tape etc. to avoid the 

air discharge.

•  Insulate the duct to avoid the dew condensation.

9374342532_IM.indb   5

9374342532_IM.indb   5

2018/12/11   10:11:30

2018/12/11   10:11:30

Содержание ARXG-KLLAP Series

Страница 1: ...installed in an explo sive atmosphere To avoid getting an electric shock never touch the electrical components soon after the power supply has been turned off After turning off the power always wait 5 min utes or more before you touch the electrical components This product contains no user serviceable parts Always consult experienced service technicians for repairing When moving or relocating the ...

Страница 2: ...ntly far away from the site of installation repairing removing and disposal during which flammable refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks No Smoking signs shall be displayed 2 6 Ventilated area Ensure that the area is in the open or th...

Страница 3: ...ior to re use of reclaimed refrigerant It is essential that electrical power is available before the task is commenced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for handling refriger ant cylinders all personal protective equipment is available and being us...

Страница 4: ... fall water leakage electric shock or fire Keep the Installation manual in a safe place and do not discard any other accessories until the installation work has been completed The following installation accessories are supplied Use them as required Name and Shape Q ty Name and Shape Q ty Operating manual 1 Cable tie large 4 Operating manual CD ROM 1 Cable tie medium 3 Installation manual This manu...

Страница 5: ...rol cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could still receive noise under some signal conditions If children under 10 years old may approach the unit take preventive measures so that they cannot reach the unit Decide the mounting position with the cus...

Страница 6: ...sed Air Intake grille Locally purchased Side inlet Side outlet Duct Insulation material Locally purchased Aluminum tape Aluminum tape Tapping screw for flange connection M4 x 10mm Locally purchased Flange Locally purchased Flange Locally purchased Air Duct Locally purchased Air Intake grille Locally purchased Bottom inlet Side outlet Duct Locally purchased Intake grille Locally purchased Air Air O...

Страница 7: ...OOD VP25 O D 32 mm or more Rise Air bleeding PROHIBITED Trap Observe the following procedures to construct centralized drain pipe fittings VP30 or more O D 38 mm or more Downward gradient 1 100 or more 700 mm or less When drain pump is not used natural drainage CAUTION Set Drainage function setting DIP switch 101 1 in 5 3 DIP switch 101 setting If the drain pump is not used please replace with the...

Страница 8: ...se as in the figure 2 Be sure to connect Drain pipe with adhesive polyvinyl chloride so that there is no leakage Applying area of adhesive Joint pipe Locally purchased Drain pipe VP25 Locally purchased 4 mm or less CAUTION Do not connect to the Drain hole with adhesive Using adhesive may cause damage and water leaks 3 After installing the Drain hose check if the drainage is smooth CAUTION To preve...

Страница 9: ...ipe avoid sharp bends If the pipe is bent repeatedly at the same place it will break The pipes are shaped by your hands Be careful not to collapse them Bend R70 mm or more with a pipe bender Do not bend the pipes in an angle more than 90 When pipes are repeatedly bend or stretched the material will harden making it difficult to bend or stretch them anymore Do not bend or stretch the pipes more tha...

Страница 10: ...ard Imperfect installation may cause a fire Use ring terminals and tighten the terminal screws to the specified torques otherwise abnormal overheating may be produced and possibly cause heavy damage inside the unit CAUTION Be careful not to generate a spark as follows for using a flammable refrigerant Do not remove the fuse while the power is on Do not disconnect the wiring while the power is on I...

Страница 11: ...ultaneous triple 18 model only Wired remote controller cable 3 wire type only Connection cable Indoor unit Primary Indoor unit Secondary Outdoor unit Earth Ground line Control line Power line Wired remote controller Remote controller cable Bus wire Locally purchased remote controller cable Max length 500 m Junction box Locally purchased Earth Ground line Red White Black Indoor unit Secondary Indoo...

Страница 12: ...1 8 12 to 18 3 6 4 Connection wiring CAUTION Be careful not to mistake the power supply cable and connection wires when install ing Install so that the wires for the remote controller will not come in contact with other connection wires 1 Remove the control box cover 2 Connect the connection cable Cover Screw Connection cable Y1 Y2 TO REMOTE CONTROL UNIT Ex IN Y3 1 2 Y1 Y2 TO REMOTE CONTROL UNIT E...

Страница 13: ...eration Stop mode or Forced stop mode can be selected with function setting of indoor unit A twisted pair cable 22 AWG should be used Maximum length of cable is 150 m 492 ft Use an external input and output cable with appropriate external dimension depending on the number of cables to be installed The wire connection should be separate from the power cable line Y1 Y2 TO REMOTE CONTROL UNIT Ex IN Y...

Страница 14: ...onnected set the function setting of indoor unit as indicated below Function Number 30 Set the Setting Number to 00 Default Function Number 31 Set the Setting Number to 02 Refer to 6 FUNCTION SETTING for details about Function number and Setting value 4 4 IR receiver unit Optional parts For the installation method please refer to the installation manual of IR receiver unit 4 4 1 Connection method ...

Страница 15: ...REMOTE CONTROL UNIT Ex IN Y3 1 2 1 2 3 SW100 a 2 wire type DIP switch RC AD SW Factory setting 00 Since the remote controller address settings are automatically configured you do not need to configure them If configuring manually it is necessary to configure both the indoor unit and the remote controller For details please refer to the remote controller installation manual b 3 wire type DIP switch...

Страница 16: ...nnection cable Remote controller cable Outdoor unit 1 Outdoor unit 2 Outdoor unit 3 Outdoor unit 4 Indoor unit 1 Indoor unit 2 Indoor unit 3 Indoor unit 4 Indoor unit 5 Indoor unit 6 Indoor unit 7 5 2 Multiple remote control Up to 2 remote controllers can be used to operate one indoor unit CAUTION Multiple installation method described above is prohibited to combine 3 Wired type with 2 Wired Type ...

Страница 17: ...ly 3 Set the primary and secondary Remote controller setting 1 Turn on all of the indoor units 2 Set the primary and secondary settings Set the indoor unit that is connected to the outdoor unit using a transmission cable as the primary Function Number Setting Value Primary 51 00 Secondary 01 3 After completing the function settings turn off all of the indoor units and then turn them back on If err...

Страница 18: ... changed Select the appropriate custom code Factory setting Function number Setting value Setting description 44 00 A 01 B 02 C 03 D External input control Operation Stop mode or Forced stop mode can be selected Factory setting Function number Setting value Setting description 46 00 Operation Stop mode 1 01 Setting prohibited 02 Forced stop mode 03 Operation Stop mode 2 Room temperature sensor swi...

Страница 19: ...in accordance with the operating manual 1 Starting and stopping method operation switching temperature adjustment timer air flow switching and other remote controller operations 2 Cleaning and maintenance of the product and other items such as air filters and air louvers if applicable 3 Give the operating and installation manuals to the customer 4 If the indoor unit custom code is changed and the ...

Страница 20: ...5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error 7 7 Heat sink temp sensor error 8 2 Sub cool Heat Ex gas inlet temp sensor error Sub cool Heat Ex gas outlet temp sensor error 8 3 Liquid pipe temp sensor error 8 4 Current sensor error 8 6 Discharge pressure sensor error Suction pressure sensor error High pressure switch error 9 4 Trip detection Error ...

Отзывы: