 3.6. Electrical wiring

 WARNING

•  Electrical work must be performed in accordance with this Manual by a person certi

fi

 ed 

under the national or regional regulations. Be sure to use a dedicated circuit for the 
unit. An insuf

fi

 cient power supply circuit or improperly performed electrical work can 

cause serious accidents such as electric shock or 

fi

 re.

•  Before starting work, check that power is not being supplied to the indoor unit and 

outdoor unit.

•  For wiring, use the prescribed type of cables, connect them securely, making sure 

that there are no external forces of the cables applied to the terminal connections.
Improperly connected or secured cables can cause serious accidents such as over-
heating the terminals, electric shock, or 

fi

 re.

•  Securely install the electrical box cover on the unit. An improperly installed electrical 

box cover can cause serious accidents such as electric shock or 

fi

 re through exposure 

to dust or water.

•  Install sleeves into any holes made in the walls for wiring. Otherwise, a short circuit 

could result.

•  Use the included connection cables and power cables or ones speci

fi

 ed by the 

manufacturer. Improper connections, insuf

fi

 cient insulation, or exceeding the allowable 

current can cause electric shock or 

fi

 re.

•  Do not modify the power cables, use extension cables, or use any branches in the 

wiring. Improper connections, insuf

fi

 cient insulation, or exceeding the allowable current 

can cause electric shock or 

fi

 re.

•  Match the terminal block numbers and connection cable colors with those of the 

outdoor unit or branch box. Erroneous wiring may cause burning of the electric parts.

•  Securely connect the connection cables to the terminal board. In addition, secure the 

cables with wiring holders. Improper connections, either in the wiring or at the ends 
of the wiring, can cause a malfunction, electric shock, or 

fi

 re.

•  Always fasten the outside covering of the connection cable with the cable clamp. (If 

the insulator is chafed, electric leakage may occur.)

•  Install an earth leakage breaker. In addition, install the earth leakage breaker so 

that the entire AC main power supply is cut off at the same time. Otherwise, electric 
shock or 

fi

 re could result.

•  Always connect the earth (ground) cable. Improper earthing (grounding) work can 

cause electric shocks.

•  Perform wiring work in accordance with standards so that the air conditioner can be 

operated safely and positively.

•  Connect the connection cable 

fi

 rmly to the terminal board. Imperfect installation may 

cause a 

fi

 re.

•  Use ring terminals and tighten the terminal screws to the speci

fi

 ed torques, otherwise, 

abnormal overheating may be produced and possibly cause heavy damage inside 
the unit.

 CAUTION

•  Be careful not to generate a spark as follows for using a 

fl

 ammable refrigerant.

-  Do not remove the fuse while the power is on.
-  Do not disconnect the wiring while the power is on. 
-  It is recommended to position the outlet connection in a high position. Place the 

cords so that they do not get tangled.

•  Earth (Ground) the unit. Do not connect the earth (ground) cable to a gas pipe, water 

pipe, lightning rod, or a telephone earth (ground) cable. Improper earthing (ground-
ing) may cause electric shock.

•  Install the remote controller cables so as not to be direct touched with your hand.
•  Do not connect power supply cables to the transmission or remote controller termi-

nals, as this will damage the product.

•  Never bundle the power supply cable and transmission cable, remote controller 

cable together. Separate these cable by 50 mm or more. Bundling these cables 
together will cause miss operation or breakdown.

•  When handling PCB, static electricity charged in the body may cause malfunction of 

the PCB. Follow the cautions below:

-  Establish an earth (a ground) for the indoor and outdoor units and peripheral 

devices.

- Cut power (breaker) off.
-  Touch metal part of the indoor and outdoor units for more than 10 seconds to 

discharge static electricity charged in the body.

- Do not touch terminals of parts and patterns implemented on PCB.

•  Be sure to refer to the above diagram for do correct 

fi

 eld wiring. Wrong wiring causes 

malfunction of the unit.

•  Check local electrical rules and also any speci

fi

 c wiring instructions or limitation.

3.6.1. Wiring system diagram

Y1

Y2

Y3

1

2

R

W

Y1

Y2

Y3

1

2

R

W

B

 

Standard pair

Indoor unit

Indoor unit

Indoor unit

Remote 
controller cable

Remote 
controller cable

*Earth (Ground) the remote controller if it has a earth (ground) line.

Red

Red

White

White

Black

Wired remote controller

Wired remote controller

Earth (Ground) line

Outdoor unit

Power line

Control line

Connection cable 

2-wire type

3-wire type

Wired remote controller cable 

 

Flexible multi

Indoor unit

Outdoor unit

Indoor unit

Red

Red

White

White
Black

Earth (Ground) line

Control line

Connection cable 

2-wire type

3-wire type

Wired remote controller cable 

Power line

Indoor unit

Indoor unit

Remote controller cable

Remote controller cable

*Earth (Ground) the remote controller if it has a earth ground) line.

Wired remote controller

Wired remote controller

UNIT

 A

UNIT

 B

9374342532_IM.indb   10

9374342532_IM.indb   10

2018/12/11   10:11:35

2018/12/11   10:11:35

Содержание ARXG-KLLAP Series

Страница 1: ...installed in an explo sive atmosphere To avoid getting an electric shock never touch the electrical components soon after the power supply has been turned off After turning off the power always wait 5 min utes or more before you touch the electrical components This product contains no user serviceable parts Always consult experienced service technicians for repairing When moving or relocating the ...

Страница 2: ...ntly far away from the site of installation repairing removing and disposal during which flammable refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks No Smoking signs shall be displayed 2 6 Ventilated area Ensure that the area is in the open or th...

Страница 3: ...ior to re use of reclaimed refrigerant It is essential that electrical power is available before the task is commenced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for handling refriger ant cylinders all personal protective equipment is available and being us...

Страница 4: ... fall water leakage electric shock or fire Keep the Installation manual in a safe place and do not discard any other accessories until the installation work has been completed The following installation accessories are supplied Use them as required Name and Shape Q ty Name and Shape Q ty Operating manual 1 Cable tie large 4 Operating manual CD ROM 1 Cable tie medium 3 Installation manual This manu...

Страница 5: ...rol cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could still receive noise under some signal conditions If children under 10 years old may approach the unit take preventive measures so that they cannot reach the unit Decide the mounting position with the cus...

Страница 6: ...sed Air Intake grille Locally purchased Side inlet Side outlet Duct Insulation material Locally purchased Aluminum tape Aluminum tape Tapping screw for flange connection M4 x 10mm Locally purchased Flange Locally purchased Flange Locally purchased Air Duct Locally purchased Air Intake grille Locally purchased Bottom inlet Side outlet Duct Locally purchased Intake grille Locally purchased Air Air O...

Страница 7: ...OOD VP25 O D 32 mm or more Rise Air bleeding PROHIBITED Trap Observe the following procedures to construct centralized drain pipe fittings VP30 or more O D 38 mm or more Downward gradient 1 100 or more 700 mm or less When drain pump is not used natural drainage CAUTION Set Drainage function setting DIP switch 101 1 in 5 3 DIP switch 101 setting If the drain pump is not used please replace with the...

Страница 8: ...se as in the figure 2 Be sure to connect Drain pipe with adhesive polyvinyl chloride so that there is no leakage Applying area of adhesive Joint pipe Locally purchased Drain pipe VP25 Locally purchased 4 mm or less CAUTION Do not connect to the Drain hole with adhesive Using adhesive may cause damage and water leaks 3 After installing the Drain hose check if the drainage is smooth CAUTION To preve...

Страница 9: ...ipe avoid sharp bends If the pipe is bent repeatedly at the same place it will break The pipes are shaped by your hands Be careful not to collapse them Bend R70 mm or more with a pipe bender Do not bend the pipes in an angle more than 90 When pipes are repeatedly bend or stretched the material will harden making it difficult to bend or stretch them anymore Do not bend or stretch the pipes more tha...

Страница 10: ...ard Imperfect installation may cause a fire Use ring terminals and tighten the terminal screws to the specified torques otherwise abnormal overheating may be produced and possibly cause heavy damage inside the unit CAUTION Be careful not to generate a spark as follows for using a flammable refrigerant Do not remove the fuse while the power is on Do not disconnect the wiring while the power is on I...

Страница 11: ...ultaneous triple 18 model only Wired remote controller cable 3 wire type only Connection cable Indoor unit Primary Indoor unit Secondary Outdoor unit Earth Ground line Control line Power line Wired remote controller Remote controller cable Bus wire Locally purchased remote controller cable Max length 500 m Junction box Locally purchased Earth Ground line Red White Black Indoor unit Secondary Indoo...

Страница 12: ...1 8 12 to 18 3 6 4 Connection wiring CAUTION Be careful not to mistake the power supply cable and connection wires when install ing Install so that the wires for the remote controller will not come in contact with other connection wires 1 Remove the control box cover 2 Connect the connection cable Cover Screw Connection cable Y1 Y2 TO REMOTE CONTROL UNIT Ex IN Y3 1 2 Y1 Y2 TO REMOTE CONTROL UNIT E...

Страница 13: ...eration Stop mode or Forced stop mode can be selected with function setting of indoor unit A twisted pair cable 22 AWG should be used Maximum length of cable is 150 m 492 ft Use an external input and output cable with appropriate external dimension depending on the number of cables to be installed The wire connection should be separate from the power cable line Y1 Y2 TO REMOTE CONTROL UNIT Ex IN Y...

Страница 14: ...onnected set the function setting of indoor unit as indicated below Function Number 30 Set the Setting Number to 00 Default Function Number 31 Set the Setting Number to 02 Refer to 6 FUNCTION SETTING for details about Function number and Setting value 4 4 IR receiver unit Optional parts For the installation method please refer to the installation manual of IR receiver unit 4 4 1 Connection method ...

Страница 15: ...REMOTE CONTROL UNIT Ex IN Y3 1 2 1 2 3 SW100 a 2 wire type DIP switch RC AD SW Factory setting 00 Since the remote controller address settings are automatically configured you do not need to configure them If configuring manually it is necessary to configure both the indoor unit and the remote controller For details please refer to the remote controller installation manual b 3 wire type DIP switch...

Страница 16: ...nnection cable Remote controller cable Outdoor unit 1 Outdoor unit 2 Outdoor unit 3 Outdoor unit 4 Indoor unit 1 Indoor unit 2 Indoor unit 3 Indoor unit 4 Indoor unit 5 Indoor unit 6 Indoor unit 7 5 2 Multiple remote control Up to 2 remote controllers can be used to operate one indoor unit CAUTION Multiple installation method described above is prohibited to combine 3 Wired type with 2 Wired Type ...

Страница 17: ...ly 3 Set the primary and secondary Remote controller setting 1 Turn on all of the indoor units 2 Set the primary and secondary settings Set the indoor unit that is connected to the outdoor unit using a transmission cable as the primary Function Number Setting Value Primary 51 00 Secondary 01 3 After completing the function settings turn off all of the indoor units and then turn them back on If err...

Страница 18: ... changed Select the appropriate custom code Factory setting Function number Setting value Setting description 44 00 A 01 B 02 C 03 D External input control Operation Stop mode or Forced stop mode can be selected Factory setting Function number Setting value Setting description 46 00 Operation Stop mode 1 01 Setting prohibited 02 Forced stop mode 03 Operation Stop mode 2 Room temperature sensor swi...

Страница 19: ...in accordance with the operating manual 1 Starting and stopping method operation switching temperature adjustment timer air flow switching and other remote controller operations 2 Cleaning and maintenance of the product and other items such as air filters and air louvers if applicable 3 Give the operating and installation manuals to the customer 4 If the indoor unit custom code is changed and the ...

Страница 20: ...5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error 7 7 Heat sink temp sensor error 8 2 Sub cool Heat Ex gas inlet temp sensor error Sub cool Heat Ex gas outlet temp sensor error 8 3 Liquid pipe temp sensor error 8 4 Current sensor error 8 6 Discharge pressure sensor error Suction pressure sensor error High pressure switch error 9 4 Trip detection Error ...

Отзывы: