Connection cable wiring

Run the connection cable to the rear of the outdoor unit within the 

A

 range of the arrows shown in the 

fi

 gure.

(The connector cover becomes dif

fi

 cult to install.)

A

 10 cm

8 cm

Hole

Connection cable

How to 

fi

 xed connection cable and power supply cable at the cable clamp

After passing the connection cable and power supply cable through the insulation tube, 
fasten it with the cable clamp.

Insulation tube

Insulation tube

Cable clamp

Use VW-1, 1.0 mm thick, PVC tube as the insulation tube.

5.4. HOW TO CONNECT THE WIRE TO THE TERMINALS

(1)   Use crimp-type terminals with insulating sleeves as shown in the 

fi

 gure below to con-

nect to the terminal block.

(2)   Securely crimp the crimp-type terminals to the wires using an appropriate tool so that 

the wires do not come loose.

(3)   Use the speci

fi

 ed wires, connect them securely, and fasten them so that there is no 

stress placed on the terminals.

(4)   Use an appropriate screwdriver to tighten the terminal screws. Do not use a screw-

driver that is too small, otherwise, the screw heads may be damaged and prevent the 
screws from being properly tightened.

(5)  Do not tighten the terminal screws too much, otherwise, the screws may break.
(6)  See the table below for the terminal screw tightening torques.

Tightening torque

M4 screw

1.2 to 1.8 N • m (12 to 18 kgf • cm)

M5 screw

2.0 to 3.0 N • m (20 to 30 kgf • cm)

Strip 
10 mm

Crimp-type terminal

Sleeve

Wire

Wire

Screw with special washer

Terminal board

Terminal block

Screw with special washer

Crimp-type terminal

Crimp-type terminal

 CAUTION

Match the terminal block numbers and connection cable colors with those of the indoor 
unit.
Erroneous wiring may cause burning of the electric parts.

Connect the connection cables 

fi

 rmly to the terminal block. Imperfect installation may 

cause a 

fi

 re.

Always fasten the outside covering of the connection cable with the cable clamp. (If the 
insulator is chafed, electric leakage may occur.)
Securely earth the power cable plug.
Do not use the earth screw for an external connector. Only use for interconnection 
between two units.

5.5. Connecting the piping

CONNECTION

(1)  Install the outdoor unit wall cap (supplied with the optional installation set or pro-

cured at the site) to the wall pipe.

(2)  Connect the outdoor unit and indoor unit piping.
(3)  After matching the center of the 

fl

 are surface and tightening the nut hand tight, 

tighten the nut to the speci

fi

 ed tightening torque with a torque wrench. (Table 1)

 CAUTION

When the outdoor temperature is 0 

˚

C or less, do not use the accessory drain pipe 

and drain cap. If the drain pipe and drain cap are used, the drain water in the pipe may 
freeze in extreme cold weather. (Reverse cycle model only)

In the area with heavy snowfall, if the intake and outlet of outdoor unit is blocked with 
snow, it might become dif

fi

 cult to get warm and it is likely to cause of the breakdown. 

Please construct a canopy and a pedestal or place the unit on a high stand (local 
con

fi

 gured).

5. INSTALLATION 

5.1. Outdoor unit installation

  Set the unit on a strong stand such as thing made of concrete blocks to minimize shock and vibration.

  Do not set the unit directly on the ground because it will cause trouble.

 WARNING

Install the unit where it will not be tilted by more than 5°.

When installing the outdoor unit where it may exposed to strong wind, fasten it securely.

5.2. Connector cover remove

Connector cover removal

 Remove the tapping screws.

Installing the connector cover

(1)  After inserting the four hooks, then push 

upward.

(2) Tighten the tapping screws.

5.3. Outdoor unit wiring

(1)  Remove the outdoor unit connector cover.
(2)  Bend the end of the cable as shown in the 

fi

 gure.

(3)  Connect the end of the connection cable fully into the terminal block.
(4)  Fasten the sheath with a cable clamp.
(5)  Install the connector cover.

Connection cable

Cable clamp

30mm

12mm

5mm

5mm

12mm

20mm

20mm

12mm

5mm

5mm

12mm

20mm

Connection cable

Power supply cable

N

L

3

2

1

Cable clamp

Earth 

screw

N

L

3

2

1

1 2

3

Outdoor unit terminal block

Indoor unit terminal block

Connection cable

Earth screw

Earth screw

Power supply cable

Tapping screw

Hooks

Tapping screw

Connector cover

9332808039_IM.indb   3

9332808039_IM.indb   3

2012-10-8   11:35:07

2012-10-8   11:35:07

Содержание AOYG24LFC

Страница 1: ...h s i l g n E INSTALLATION MANUAL For authorized service personnel only INSTALLATION MANUAL AOYG24LFC OUTDOOR UNIT PART No 9332809039 ...

Страница 2: ...egulation and laws in use on installation place The installation must be carried out in compliance with regulations in force in the place of installation and the installation instructions of the manufacturer This unit is part of a set constituting an air conditioner It must not be installed alone or with non authorized by the manufacturer The unit must be correctly earthed grounded and the supply ...

Страница 3: ...0 g 200 g 300 g 20 g m CAUTION When adding refrigerant add the refrigerant from the charging port at the completion of work The maximum length of the piping is 30 m If the units are further apart than this correct operation can not be guaranteed 2 6 Accessories The following installation accessories are supplied Use them as required Drain pipe 1 Drain cap 3 Installation manual 1 One set of followi...

Страница 4: ...e plug Do not use the earth screw for an external connector Only use for interconnection between two units 5 5 Connecting the piping CONNECTION 1 Install the outdoor unit wall cap supplied with the optional installation set or pro cured at the site to the wall pipe 2 Connect the outdoor unit and indoor unit piping 3 After matching the center of the flare surface and tightening the nut hand tight t...

Страница 5: ...open the valve stems of the 2 way valve and 3 way valve using a hexagon wrench After the valve stem begins to turn turn it with a torque of less than 2 9 N m 30 kgf cm until it stops turning 11 Firmly tighten the 2 way valve and 3 way valve blank cap and the charging port cap 3 way valve 2 way valve Charging port cap Vacuum pump Charge hose Charge hose Charging port Blank cap Valve stem Flare nut ...

Отзывы: