Fujitsu AOYG12KETA Скачать руководство пользователя страница 8

En-7

 7.  ENERGY SAVING OPERATION

 7.1. Economy operation

It saves more electricity than other operation modes by changing the set 
temperature to a moderate setting.

Press 

 to activate/deactivate the Economy 

operation.

[   ] indicator on the indoor unit will turn on.

Operation 

mode

Room temperature

Cooling/Dry

Few degrees higher than the set temperature

Heating

Few degrees lower than the set temperature

NOTES:

•  In the Cooling, Heating, or Dry mode, the maximum output of this 

operation is approximately 70 % of usual operation.

•  This operation cannot be performed during the temperature 

monitoring by the Auto mode.

 8.2.  Outdoor Unit Low Noise operation

The Outdoor Unit Low Noise operation lowers noise from the outdoor 
unit. During this operation, the rotation number of the compressor 
decreases and the outdoor unit fan rotates slowly.

NOTES: 

In multi connection, this function cannot be used.

Press 

 to activate/deactivate the Outdoor Unit Low 

Noise operation.

While the Outdoor Unit Low Noise operation is activated, 

 

on the remote controller is displayed.
The setting is preserved even if the air conditioner is turned off.

NOTES: 

•  This operation cannot be performed simultaneously with the Fan 

mode, Dry mode, and Powerful operation.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

 8.3.  10 °C Heat operation

10 °C Heat operation maintains the room temperature at 10 °C so as to 
prevent the room temperature to drop too low.

Press 

 to activate the 10 °C Heat operation.

The indoor unit will emit 1 short beep and [   ] indicator on the 
indoor unit will turn on.

Press 

 to turn off the air conditioner. 

 ] indicator will turn off.

NOTES:

•  During the 10 °C Heat operation, only 

 is valid.

•  When the room temperature is warm enough, this operation will not 

perform.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

During the Sleep timer operation, the setting temperature changes as 
the following 

fi

 gure.

In Heating mode

Set
temperature

Set time

1 hour

Set time

1 hour

1.5 hour

30 min.

1 °C 2 °C 3 °C 4 °C

2 °C

1 °C

In Cooling or Dry mode

After the set time has elapsed, the air conditioner operation turns off.

 8. OTHER OPERATIONS

 8.1. Powerful operation

In the Powerful operation, the air conditioner will operate at maximum 
power and strong air

fl

 ow to cool down or warm up the room quickly.

NOTES: 

In multi connection, this function cannot be used.

Press 

 to activate/deactivate the Powerful operation.

When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.

The Powerful operation will be turned off automatically in the following 
situations:

•  The Powerful operation runs for a certain amount of time and the 

room temperature reaches the set temperature in the Cooling, Dry, 
or Heating mode.

•  20 minutes after the Powerful operation has started.

NOTES:

• The air

fl

 ow direction and the fan speed are controlled automatically.

•  The Powerful operation cannot be performed simultaneously with 

Economy operation.

•  The Powerful operation overrides the following operations. If 

the following operations are set, they will start after the Powerful 
operation 

fi

 nishes.

 

- Outdoor Unit Low Noise operation

 

- Energy Saving program

•  If the wired remote controller (optional) is connected, this function is 

restricted.

9.  SETTINGS ON INSTALLATION

9.1.  Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can 
specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to 
operate them separately, set the custom code (4 selections possible).

NOTES: 

If custom codes is different between the indoor unit and the 

remote controller, the indoor unit cannot receive a signal from 
the remote controller.

How to set the remote controller custom code

1. 

 Press 

 until only the clock is displayed on the remote 

controller display.

2. 

 Press and hold

 

 

for more than 

5 seconds.

The current custom code will be 
displayed (initially set to A).

3. 

Press 

 to change the 

custom code between A

B

C

(

).

* Match the custom code on the display 
to the air conditioner custom code.

4. 

Press 

 again.

The custom code will be set. 
The display  will return to the clock display.

00_9387858037_OM.indb   7

00_9387858037_OM.indb   7

2019/8/26   17:12:03

2019/8/26   17:12:03

Содержание AOYG12KETA

Страница 1: ...er ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di utilizzare l apparecchio leggere...

Страница 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Страница 3: ...oor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any othe...

Страница 4: ...lter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation W LAN optional Orange W LAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to the operating manual of each remote controller The se...

Страница 5: ...ion Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the ti...

Страница 6: ...y saving that enables power saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped In initial setting this function is activated To deactivate the function consult the installer or authorized service personnel In the Heating mode set the temperature higher than the current room temperature at the beginning of the operation the indoor unit fan rotates at v...

Страница 7: ...simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Prog...

Страница 8: ... Cooling or Dry mode After the set time has elapsed the air conditioner operation turns off 8 OTHER OPERATIONS 8 1 Powerful operation In the Powerful operation the air conditioner will operate at maximum power and strong airflow to cool down or warm up the room quickly NOTES In multi connection this function cannot be used Press to activate deactivate the Powerful operation When activated the indo...

Страница 9: ...s are sold separately When you replace them please contact the store of purchase Cleaning indoor unit body NOTES Do not use water hotter than 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner 1 Wipe the indoor unit body gently with a soft cloth moisten with warm water 2 Wipe the indoor unit body gently with a dry and soft cloth Cleaning air filter 1 Open the intake gri...

Страница 10: ...rder to use this function Clean the air filter when the indicator lamp show the following Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and trans...

Страница 11: ...lectric shock or damage to the product may occur Do not standing on an unstable platform when installing or removing this product to avoid injury 1 Be sure to turn air conditioner off and to disconnect all the power supply 2 Open the intake grille 3 Open the W LAN adapter cover until it snaps 4 Plug the W LAN adapter into the connection slot of the indoor unit in the direction as shown in the figu...

Страница 12: ...emote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case please repeat the remote control...

Страница 13: ...may be emitted during the operation 12 4 Multi type air conditioner This indoor unit can be connected to a multi type outdoor unit The multi type air conditioner allows multiple indoor units to be operated in multiple locations The indoor units may be operated simultaneously in accordance with their respective output Simultaneous Use of Multiple Units When using a multi type air conditioner the mu...

Страница 14: ...rn Blinking Any state State Causes and solutions See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 9 Filter indicator Clean the air filter and reset the filter sign 9 Demand response operation 7 Error code display Consult authorized service personnel Timer setting error because of Auto restart Reset the clock and timer settings 9 Test run oper...