5.1.  Fan speed setting

 Press 

 to control the fan speed.

The fan speed changes as follows.

(Auto)

(High)

(Med)

(Low)

(Quiet)

When 

 is selected, the fan speed depends on the operating 

condition.

To increase the air cleaning effect, set the fan speed to High.

5.2. Air

fl

 ow direction setting

For details of the air

fl

 ow ranges, refer to “Air

fl

 ow direction 

range”.

 

Vertical air

fl

 ow direction setting

Press 

 to adjust the vertical air

fl

 ow direction.

 6. TIMER OPERATIONS

NOTES: 

When [   ] indicator on the indoor unit blinks, set the clock 

and timer again. This blinking shows that the internal clock go 
wrong due to an interruption of the power supply. (Refer to 
page 9.)

 

Timer setting procedure

Before setting the timer, please adjust the clock. (Refer to “remote 
controller preparation”).

1. 

Press 

.

 on the remote controller display will blink.

2. 

Press 

(

)

 to choose timer operation.

The timer operation will change as follows:

[

]

[

]

[

]

Weekly timer

Enables you to set operation 
schedules up to 4 setting for each 
day of the week.

On timer

Starts the operation at your desired 
time.

Off timer

Stops the operation at your desired 
time.

Program timer

Operates as the combination of the 
On timer and Off timer.

Sleep timer

Supports your comfortable sleep 
by moderating the air conditioner 
operation gradually.

3. 

Press 

.

4. 

Set each timer operation.

For details, refer to the following instructions of each timer setting.

 4. BASIC OPERATIONS

 

3 steps to start operation

1. 

Press 

 to start or stop the operation.

2. 

Press 

 to select the operation mode.

The operation mode changes as follows.

AUTO  

COOL  

DRY  

FAN  

HEAT

3. 

Press 

 to set the desired temperature.

The temperature changes by 0.5 °C increments.

Temperature setting range

Auto/Cooling/Dry

18.0 to 30.0 °C

Heating

16.0 to 30.0 °C

NOTES:

•  In the Cooling or Dry mode, set the temperature lower than the 

current room temperature.

•  In the Cooling mode, the indoor unit fan may stop from time to time 

to perform Fan control for energy saving that enables power-saving 
operation by stopping the rotation of the indoor unit fan when the 
outdoor unit is stopped.
In initial setting, this function is activated.
To deactivate the function, consult the installer or authorized service 
personnel.

•  In the Heating mode,

 

- set the temperature higher than the current room temperature.

 

- at the beginning of the operation, the indoor unit fan rotates at very 

low speed for 3-5 minutes.

 

- the Automatic defrosting operation overrides the Heating operation 

when necessary.

•  In the Fan mode, temperature control is not available. 

 

Temperature unit switching

1. 

Press 

 until only the clock is displayed.

2. 

Press down 

 for more than 5 seconds.

The current temperature unit will be displayed. (Factory setting: °C)

3. 

Press 

 to switch the temperature unit. (°C 

°F)

4. 

Press 

 to 

fi

 nish the setting.

If you do not press the button for 30 seconds, the displayed 
temperature unit will be set.

 

Horizontal air

fl

 ow direction setting

 

CAUTION

Before you adjust the horizontal air

fl

 ow direction, make 

sure that the vertical air

fl

 ow direction louver has been 

stopped completely.

Adjust two knobs by hand.

 

Swing operation setting

Press 

 to start/stop the Swing operation.

NOTES:

 The Swing operation may stop temporarily when the indoor 

unit fan is rotating at very low speed or is stopped.

 

Air

fl

 ow direction range

Vertical air

fl

 ow direction

Change by 

 

1

2

3

4

5

6

Swing operation by 

Cooling, Dry

1

4

Heating

3

6

Fan *

1

4 or 3

6

* The Swing operation range depends on the air

fl

 ow direction set before 

the Swing operation.

NOTES:

•  Do not adjust the air

fl

 ow direction louvers by hand.

•  In the Auto or Heating mode, the air

fl

 ow direction stay position 1 for 

a while from the start of the operation.

•  In the Cooling or Dry mode, position 1-3 is recommended to prevent 

condensation drips damaging your property. If position 4-6 keeps for 
30 minutes or more in these modes, the air

fl

 ow direction changes to 

position 3 automatically.

•  When using the mobile app (optional W-LAN control is necessary), 

the vertical air

fl

 ow can be selected from 4 positions.

00_9387858037_OM.indb   5

00_9387858037_OM.indb   5

2019/8/26   17:12:03

2019/8/26   17:12:03

Содержание AOYG12KETA

Страница 1: ...er ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di utilizzare l apparecchio leggere...

Страница 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Страница 3: ...oor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any othe...

Страница 4: ...lter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation W LAN optional Orange W LAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to the operating manual of each remote controller The se...

Страница 5: ...ion Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the ti...

Страница 6: ...y saving that enables power saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped In initial setting this function is activated To deactivate the function consult the installer or authorized service personnel In the Heating mode set the temperature higher than the current room temperature at the beginning of the operation the indoor unit fan rotates at v...

Страница 7: ...simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Prog...

Страница 8: ... Cooling or Dry mode After the set time has elapsed the air conditioner operation turns off 8 OTHER OPERATIONS 8 1 Powerful operation In the Powerful operation the air conditioner will operate at maximum power and strong airflow to cool down or warm up the room quickly NOTES In multi connection this function cannot be used Press to activate deactivate the Powerful operation When activated the indo...

Страница 9: ...s are sold separately When you replace them please contact the store of purchase Cleaning indoor unit body NOTES Do not use water hotter than 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner 1 Wipe the indoor unit body gently with a soft cloth moisten with warm water 2 Wipe the indoor unit body gently with a dry and soft cloth Cleaning air filter 1 Open the intake gri...

Страница 10: ...rder to use this function Clean the air filter when the indicator lamp show the following Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and trans...

Страница 11: ...lectric shock or damage to the product may occur Do not standing on an unstable platform when installing or removing this product to avoid injury 1 Be sure to turn air conditioner off and to disconnect all the power supply 2 Open the intake grille 3 Open the W LAN adapter cover until it snaps 4 Plug the W LAN adapter into the connection slot of the indoor unit in the direction as shown in the figu...

Страница 12: ...emote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case please repeat the remote control...

Страница 13: ...may be emitted during the operation 12 4 Multi type air conditioner This indoor unit can be connected to a multi type outdoor unit The multi type air conditioner allows multiple indoor units to be operated in multiple locations The indoor units may be operated simultaneously in accordance with their respective output Simultaneous Use of Multiple Units When using a multi type air conditioner the mu...

Страница 14: ...rn Blinking Any state State Causes and solutions See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 9 Filter indicator Clean the air filter and reset the filter sign 9 Demand response operation 7 Error code display Consult authorized service personnel Timer setting error because of Auto restart Reset the clock and timer settings 9 Test run oper...

Отзывы: