Optional part

Part name

Model name

Exterior

External connect kit

UTY-XWZXZ5

External input wire

Communication kit

UTY-TWBXF1

* For operating the external function, the wall mounted type requires the communication kit in addi-
tion to the wire (UTY-XWZXZ5).

- 19 -

8-1. External input

8. External input and output

WALL MOUNTED

ASYG09-14KHCA

WALL MOUNTED

ASYG09-14KHCA

Содержание AOYG09KHCAN

Страница 1: ...AIR CONDITIONER Wall mounted type DESIGN TECHNICAL MANUAL INDOOR ASYG09KHCA ASYG12KHCA ASYG14KHCA OUTDOOR AOYG09KHCAN AOYG12KHCAN AOYG14KHCAN DR_AS112EF_04 2020 02 14 ...

Страница 2: ...please check with our authorized dealer Trademarks FGLair is trademark of Fujitsu General Limited in the United States other countries or both Google Play is trademark of Google Inc App Store is a service mark of Apple Inc registered in the U S and other countries Copyright 2019 Fujitsu General Limited All rights reserved ...

Страница 3: ...ration noise sound pressure 14 6 1 Noise level curve 14 6 2 Sound level check point 15 7 Safety devices 16 8 External input and output 17 8 1 External input 17 8 2 External output 20 9 Group connection 22 10 Remote controller 23 10 1 Wireless remote controller 23 11 Function settings 25 11 1 Function settings by using remote controller 25 11 2 Custom code setting for wireless remote controller 29 ...

Страница 4: ...city compensation rate for pipe length and height difference 41 6 1 Model AOYG09KHCAN 41 6 2 Model AOYG12KHCAN 42 6 3 Model AOYG14KHCAN 42 7 Additional charge calculation 43 7 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 43 8 Airflow 44 8 1 Model AOYG09KHCAN 44 8 2 Model AOYG12KHCAN 44 8 3 Model AOYG14KHCAN 44 9 Operation noise sound pressure 45 9 1 Noise level curve 45 9 2 Sound level check p...

Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG09KHCA ASYG12KHCA ASYG14KHCA ...

Страница 6: ...0 1 8 1 1 1 9 1 7 3 0 Maximum operating current 1 Cooling A 6 5 7 5 9 0 Heating 10 5 11 0 11 5 Fan Airflow rate Cooling HIGH m3 h 830 900 MED 680 780 LOW 580 630 QUIET 380 440 Heating HIGH 830 900 MED 680 780 LOW 580 630 QUIET 380 500 Type Q ty Cross flow fan 1 Motor output W 61 Sound pressure level 2 Cooling HIGH dB A 42 45 MED 37 40 LOW 33 35 QUIET 23 26 Heating HIGH 41 44 MED 35 39 LOW 31 33 QU...

Страница 7: ...unit Protective function might work when using it outside the operation range 1 Maximum current is maximum value when operated within the operation range 2 Sound pressure level Measured values in manufacturer s anechoic chamber Because of the surrounding sound environment the sound levels measured in actual installation conditions might be higher than the specified values here 3 Available on Googl...

Страница 8: ... 5 35 C 3 5 35 C 4 2 35 C Heating Average 2 5 10 C 3 5 10 C 4 2 10 C SEER Cooling kWh kWh 9 36 9 06 8 36 SCOP Heating Average 5 21 4 89 4 86 Annual energy consumption QCE kWh a 93 135 176 QHE Average 671 1 001 1 209 Sound power level Cooling HIGH dB A 57 57 60 Heating 57 57 60 4 1 Specifications WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 9: ...ASYG14KHCA Unit mm 375 for pipe inlet Ø 65 for pipe inlet Ø 65 387 Outline of unit 470 470 270 43 295 295 940 940 387 83 77 393 40 9 43 5 2 1 Models ASYG09KHCA ASYG12KHCA and ASYG14KHCA 2 Dimensions WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 10: ...n space for product safety Outline of unit Unit mm 50 or more 127 or more 50 or more 133 or more 1 500 or more 50 or more 84 or more 1 800 or more 6 2 1 Models ASYG09KHCA ASYG12KHCA and ASYG14KHCA 2 Dimensions WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 11: ...3 Wiring diagrams 3 1 Models ASYG09KHCA ASYG12KHCA and ASYG14KHCA 7 3 1 Models ASYG09KHCA ASYG12KHCA and ASYG14KHCA 3 Wiring diagrams WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 12: ...78 2 37 0 24 3 11 2 38 0 24 3 27 2 49 0 24 3 47 2 64 0 24 3 53 2 81 0 25 3 74 2 79 0 25 3 95 2 97 0 26 10 0 2 76 2 36 0 24 3 08 2 37 0 24 3 24 2 49 0 25 3 44 2 63 0 25 3 50 2 79 0 25 3 71 2 79 0 25 3 92 2 97 0 26 15 0 2 90 2 49 0 27 3 24 2 51 0 27 3 40 2 62 0 27 3 62 2 77 0 28 3 68 2 95 0 28 3 90 2 94 0 28 4 12 3 13 0 28 20 0 3 28 2 70 0 50 3 65 2 71 0 51 3 77 2 83 0 51 4 02 3 00 0 52 4 15 3 19 0 ...

Страница 13: ... 2 05 4 99 2 13 4 85 2 17 5 7 6 15 1 99 6 00 2 03 5 86 2 07 5 56 2 16 5 41 2 19 0 2 6 58 2 03 6 42 2 07 6 26 2 11 5 95 2 19 5 79 2 24 5 3 7 40 2 11 7 23 2 16 7 05 2 20 6 70 2 29 6 52 2 34 7 6 7 77 2 15 7 58 2 18 7 40 2 24 7 03 2 33 6 84 2 38 10 8 8 16 2 01 7 97 2 05 7 78 2 10 7 39 2 18 7 19 2 22 15 10 8 36 1 82 8 16 1 87 7 96 1 90 7 56 1 98 7 37 2 01 20 15 8 63 1 63 8 42 1 67 8 21 1 70 7 80 1 77 7...

Страница 14: ...ouver Up Horizontal airflow direction louver Left Right 3 2 1 0 1 2 3 Unit m s m m 0 1 2 3 4 5 6 7 8 9 2 0 2 0 1 0 1 0 0 5 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 0 0 5 1 0 3 2 1 0 Unit m s m m 0 1 2 3 4 5 6 7 8 9 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 0 0 5 1 0 3 2 1 0 Unit m s m m 0 1 2...

Страница 15: ...ction louver Left Right 2 0 2 0 1 0 1 0 0 5 0 5 3 2 1 0 1 2 3 Unit m s m m 0 1 2 3 4 5 6 7 8 9 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 0 1 0 0 5 3 2 1 0 Unit m s m m 0 1 2 3 4 5 6 7 8 9 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 0 1 0 0 5 3 2 1 0 Unit m s m m 0 1 2 3 4 5 6 7 8 9 11 5 1 Air veloci...

Страница 16: ...680 l s 189 CFM 400 LOW m3 h 580 l s 161 CFM 341 QUIET m3 h 380 l s 106 CFM 224 Heating Fan speed Airflow HIGH m3 h 830 l s 231 CFM 489 MED m3 h 680 l s 189 CFM 400 LOW m3 h 580 l s 161 CFM 341 QUIET m3 h 380 l s 106 CFM 224 12 5 2 Airflow 5 Fan performance WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 17: ...FM 459 LOW m3 h 630 l s 175 CFM 371 QUIET m3 h 440 l s 122 CFM 259 Heating Fan speed Airflow HIGH m3 h 900 l s 250 CFM 530 MED m3 h 780 l s 217 CFM 459 LOW m3 h 630 l s 175 CFM 371 QUIET m3 h 500 l s 139 CFM 294 13 5 2 Airflow 5 Fan performance WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 18: ...70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH QUIET Model ASYG12KHCA Cooling NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH QUIET Heating NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 O...

Страница 19: ... 4 000 8 000 HIGH QUIET Heating NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH QUIET 6 2 Sound level check point Microphone Microphone 1 m 0 8 m 15 6 1 Noise level curve 6 Operation noise sound pressure WALL MOUNTED ASYG09 14K...

Страница 20: ...KHCA ASYG14KHCA Circuit protection Current fuse PCB 250 V 3 15 A Fan motor protection Thermal protector program Activate 150 15 C Fan motor stop Reset 120 15 C Fan motor restart PCB Printed Circuit Board 16 7 Safety devices WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 21: ...ction should be separate from the power cable line Control input Operation Stop or Forced stop The air conditioner can be remotely operated by means of the following on site work Unit operation is started at the following contents by adding the contact input of a commercial on off switch to a connector on the external control PCB and turning it on Unit operation Initial setting after power is on S...

Страница 22: ...gnal Indoor unit When function setting is Forced stop mode Remote controller On On On Input signal Indoor unit Command Remote control operation invalidity On Off Operation Stop Forced stop Normal When function setting is Operation Stop mode 2 On Input Off Operation Indoor unit Stop R C disabled Remote controller On On Off NOTE When Operation Stop mode 2 function is used with forming a remote contr...

Страница 23: ... External input wire Communication kit UTY TWBXF1 For operating the external function the wall mounted type requires the communication kit in addi tion to the wire UTY XWZXZ5 19 8 1 External input 8 External input and output WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 24: ...it 1 2 Signal Relay power supply V Connector 10 m DC 24 V Make the distance from the PCB to the connected unit within 10 m Relay spec Max DC 24 V 10 mA to less than 500 mA On Off Operation Stop Indoor unit Output signal Optional part Part name Model name Exterior External connect kit UTY XWZXZ5 External output wire Communication kit UTY TWBXF1 For operating the external function the wall mounted t...

Страница 25: ...ted unit within 10 m Relay spec Max DC 24 V 10 mA to less than 500 mA On Off Error Normal Error status Output signal Optional part Part name Model name Exterior External connect kit UTY XWZXZ5 External output wire Communication kit UTY TWBXF1 For operating the external function the wall mounted type requires the communication kit in addition to the wire UTY XWZXZ5 21 8 2 External output 8 External...

Страница 26: ... this unit In such a case do not change the remote controller address for the indoor unit and keep it at the initial setting of 00 Only set addresses manually when using different numbers for addresses Set the R C address of each indoor unit using the function setting Refer to Remote con troller address setting in Contents of function setting on page 26 NOTES Do not use the same setting value Sett...

Страница 27: ...of the indoor unit For details refer to the operation manual Display panel Mode indicator ENERGY SAVING mode indicator LOW NOISE mode indicator Turns on when the SENSOR button is operated Ü Clock and Timer indicator SEND indicator Transmit indicator Temperature indicator Fan speed indicator Swing indicator To facilitate explanation the accompanying illustration has been drawn to show all possible ...

Страница 28: ...5 61 17 Weight g 124 without batteries Holder Unit mm 48 5 5 5 26 2 69 3 6 5 Front View Side View Bottom View Ø 3 5 Hole 150 106 8 Hole 3 5 2 R Size H W D mm 150 69 3 26 2 Weight g 27 24 10 1 Wireless remote controller 10 Remote controller WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 29: ... invalid numbers or setting values are selected When optional wired remote controller is used refer to the installation manual enclosed with the remote controller Entering function setting mode While pressing the POWERFUL button and TEMP button simulta neously press the RESET button to enter the function setting mode Function number Setting value Selecting the function number and setting value 1 P...

Страница 30: ...itching Aux 9 49 Indoor unit fan control for energy saving for cooling 1 Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room If the indication is not required select No indication 03 Function number Setting value Setting description Factory setting 11 00 Standard 400 hours 01 Long interval 1 000...

Страница 31: ...r switching When using the wired remote controller temperature sensor change the setting to Both 01 Function number Setting value Setting description Factory setting 42 00 Indoor unit 01 Both 00 Sensor on the indoor unit is active 01 Sensors on both indoor unit and wired remote controller are active NOTE Remote controller sensor must be turned on by using the remote controller 6 Remote controller ...

Страница 32: ...mote controller 9 Indoor unit fan control for energy saving for cooling Enables or disables the power saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation Function number Setting value Setting description Factory setting 49 00 Disable 01 Enable 00 When the outdoor unit is stopped the indoor unit fan operates continuously following th...

Страница 33: ...STOP button until only the clock is displayed on the remote controller display 2 Press the MODE button for at least 5 seconds to display the cur rent custom code Initially set to 3 Press the TEMP buttons to change the custom code be tween Match the code on the display to the air con ditioner custom code Initially set to 4 Press the MODE button again to return to the clock display The custom code w...

Страница 34: ...h tape 1 Operating manual CD ROM 1 Wall hook bracket 1 Installation manual 1 Tapping screw large 5 Remote controller 1 Tapping screw small 2 Battery 2 Air cleaning filter 2 Remote controller holder 1 Filter holder 2 30 12 1 Models ASYG09KHCA ASYG12KHCA and ASYG14KHCA 12 Accessories WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 35: ...ates on the basic functions such as Start Stop fan control temperature setting and operation mode Wire type Polar 3 wire Optional communication kit is necessary for installation NOTE Available functions may differ by the remote controller For details refer to the operation manual 13 2 Others Exterior Part name Model name Summary External connect kit UTY XWZXZ5 Required when external device is conn...

Страница 36: ... 32 13 2 Others 13 Optional parts WALL MOUNTED ASYG09 14KHCA WALL MOUNTED ASYG09 14KHCA ...

Страница 37: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG09KHCAN AOYG12KHCAN AOYG14KHCAN ...

Страница 38: ...t cm3 350 Enclosure Material Steel sheet Color Beige Approximate color of Munsell 10YR 7 5 1 0 Dimensions H W D Net mm 620 790 290 Gross 713 945 395 Weight Net kg 36 Gross 40 Connection pipe Size Liquid mm in Ø 6 35 Ø 1 4 Gas Ø 9 52 Ø 3 8 Method Flare Pre charge length m 15 Max length 20 Max height difference 15 Operation range Cooling C 10 to 46 Heating 25 to 24 NOTES Specifications are based on ...

Страница 39: ...w 18 62 290 18 20 20 9 110 620 209 352 175 320 4 ø11 3 mm hole 540 Airflow ø20 hole Bottom view 6x20 120 6x20 120 25 23 25 23 55 55 10 10 10 20 20 hole 17 5 25 10 10 hole 102 35 2 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 2 Dimensions OUTDOOR UNIT AOYG09 14KHCAN OUTDOOR UNIT AOYG09 14KHCAN ...

Страница 40: ...ore 100 or more 100 or more When there are obstacles at the front only When there are obstacles at the front and rear 600 or more 600 or more 100 or more When there is an obstruction in the upper space Unit mm When there are obstacles at the rear and above When there are obstacles at the rear sides and above 100 or more Max 200 600 or more 600 or more 100 or more 250 or more 100 or more Max 200 36...

Страница 41: ... or more 1 000 or more When there are obstacles at the front and rear 200 or more 1 000 or more When there is an obstruction in the upper space Unit mm When there are obstacles at the rear and above 1 500 or more 200 or more Max 300 37 3 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 3 Installation space OUTDOOR UNIT AOYG09 14KHCAN OUTDOOR UNIT AOYG09 14KHCAN ...

Страница 42: ...re the drain water could freeze Otherwise the drainage from the upper unit may form ice and cause a malfunction of the lower unit When the outdoor temperature is 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold climate For reverse cycle model only In area with heavy snowfall if the inlet ...

Страница 43: ...charge temp Thermistor Outdoor temp Thermistor Heat exchanger out temp ThO ThHO Compressor Muffler Muffler Heat exchanger INDOOR Heat exchanger OUTDOOR 3 Way valve 2 Way valve Cooling Heating Receiver Strainer Strainer Expansion valve 39 4 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 4 Refrigerant circuit OUTDOOR UNIT AOYG09 14KHCAN OUTDOOR UNIT AOYG09 14KHCAN ...

Страница 44: ...5 Wiring diagrams 5 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 40 5 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 5 Wiring diagrams OUTDOOR UNIT AOYG09 14KHCAN OUTDOOR UNIT AOYG09 14KHCAN ...

Страница 45: ... 941 5 0 992 0 984 0 971 0 936 0 945 0 1 000 0 992 0 979 0 943 0 953 Indoor unit is lower than outdoor unit 2 5 1 000 0 992 0 979 0 943 0 953 7 5 0 992 0 979 0 943 0 953 10 0 979 0 943 0 953 15 0 943 0 953 HEATING Pipe length m 5 7 5 10 15 20 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 990 0 969 10 1 002 0 990 0 969 7 5 1 001 1 002 0 990 0 969 5 1 000 1 001 1 002 0 990 0 9...

Страница 46: ...0 942 0 923 15 0 933 0 913 6 3 Model AOYG14KHCAN NOTE Values mentioned in the table are calculated based on the maximum capacity COOLING Pipe length m 5 7 5 10 15 20 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 866 0 869 10 0 926 0 867 0 876 7 5 0 959 0 929 0 871 0 880 5 0 992 0 963 0 933 0 874 0 883 0 1 000 0 970 0 941 0 881 0 890 Indoor unit is lower than outdoor unit 2 5...

Страница 47: ...frigerant type R32 Factory charge amount g 1 100 Refrigerant charge Total pipe length m 15 or less 20 Max 20 g m Additional charge amount g 0 100 43 7 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 7 Additional charge calculation OUTDOOR UNIT AOYG09 14KHCAN OUTDOOR UNIT AOYG09 14KHCAN ...

Страница 48: ... 431 CFM 912 8 2 Model AOYG12KHCAN Cooling m3 h 2 050 l s 569 CFM 1 207 Heating m3 h 1 780 l s 494 CFM 1 048 8 3 Model AOYG14KHCAN Cooling m3 h 2 460 l s 683 CFM 1 448 Heating m3 h 1 780 l s 431 CFM 912 44 8 1 Model AOYG09KHCAN 8 Airflow OUTDOOR UNIT AOYG09 14KHCAN OUTDOOR UNIT AOYG09 14KHCAN ...

Страница 49: ...8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Model AOYG12KHCAN Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center freque...

Страница 50: ... 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 9 2 Sound level check point 1 m Microphone Microphone Rear Airflow Rear view Side view NOTE Detailed shape of the actual outdoor unit might be slightly different from the one illustrated above 46 9 1 Noise level curve 9...

Страница 51: ... length m 21 1 Maximum operating current is the total current of the indoor unit and the outdoor unit 2 Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005 As the regulations of wire size and circuit breaker differ in each country or region select appropriate de vices complied to the regional standard 3 Limit voltage drop to less than 2 If voltage drop is 2 or more ...

Страница 52: ...rmal protection program Activate 125 10 C Fan motor stop Reset 120 10 C Fan motor restart Compressor protection Thermal protection program Discharge temp Activate 110 C Compressor stop Reset After 7 minutes Compressor restart Thermal protection program Outdoor temp Only in COOL or DRY mode Activate 15 C Compressor stop Reset 10 C Compressor restart 48 11 Safety devices OUTDOOR UNIT AOYG09 14KHCAN ...

Страница 53: ...G09KHCAN AOYG12KHCAN and AOYG14KHCAN Part name Exterior Q ty Part name Exterior Q ty Installation manual 1 49 12 1 Models AOYG09KHCAN AOYG12KHCAN and AOYG14KHCAN 12 Accessories OUTDOOR UNIT AOYG09 14KHCAN OUTDOOR UNIT AOYG09 14KHCAN ...

Отзывы: